Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tex Heart Inst J ; 49(1)2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35099560

RESUMO

Open surgical aortic valve replacement (SAVR) is a viable alternative to transcatheter implantation in low-risk patients. In this light, we evaluated the safety and effectiveness of SAVR performed through conventional and less invasive surgical approaches in a high-volume center. We retrospectively reviewed the records of 395 consecutive patients who underwent open SAVR from January 2019 through December 2019 in our center. We evaluated and compared the operative results and postoperative major adverse outcomes of 3 surgical approaches: full median sternotomy (n=267), upper ministernotomy (ministernotomy) (n=106), and right anterior thoracotomy (minithoracotomy) (n=22). Overall, the 30-day all-cause mortality rate was 0.8% (3 patients). Stroke occurred in 8 patients (2%), disabling stroke in 4 patients (1%), myocardial infarction in 1 (0.2%), and surgical site infection in 13 (3.2%). There was no difference in 30-day mortality rate or incidence of postoperative major adverse events among the 3 surgical groups. Stroke and surgical site infection occurred more frequently, but not significantly so, in the full-sternotomy group. The mean hospital stay was longer after full sternotomy (9.1 ± 5.5 d) than after ministernotomy (7.5 ± 2.9 d) or minithoracotomy (7.4 ± 1.9 d) (P=0.012). Our findings suggest that open SAVR performed in a high-volume center is associated with a low early mortality rate and that less invasive approaches result in faster postoperative recovery and shorter hospital stays.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Esternotomia/efeitos adversos , Esternotomia/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Eur J Cardiothorac Surg ; 61(5): 1068-1075, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915555

RESUMO

OBJECTIVES: The German Registry of Acute Aortic Dissection Type A (GERAADA) on-line score calculator to predict 30-day mortality in patients undergoing surgery for acute type A aortic dissection (ATAAD) was recently launched. Using the European System for Cardiac Operative Risk Evaluation II (EuroSCORE II), it is also possible to predict operative mortality for the same type of surgery. The goal of our study was to validate the prediction accuracy of these 2 on-line risk prediction models. METHODS: Prospectively collected data for EuroSCORE II risk factors as well as all data for GERAADA scoring were extracted from an institutional database for 147 patients who underwent surgery for ATAAD between April 2018 and April 2021. The discriminative power was assessed using area under the receiver operating characteristic curve. The calibration of the models was tested by the Hosmer-Lemeshow statistics and by using the observed-to-expected (O/E) mortality ratio with the 95% confidence interval. RESULTS: The observed operative mortality was 14.3%. The mean predicted mortality rates for the GERAADA score and the EuroSCORE II were 15.6% and 10.6%, respectively. The EuroSCORE II discriminative power (area under the curve = 0.799) significantly outperformed the discriminatory power of the GERAADA score (area under the curve = 0.550). The Hosmer-Lemeshow statistics confirmed good calibration for both models (P-values of 0.49 and 0.29 for the GERAADA score and the EuroSCORE II, respectively). The O/E mortality ratio certified good calibration for both scores [GERAADA score (O/E ratio of 0.93, 95% confidence interval: 0.53-1.33); EuroSCORE II (O/E ratio of 1.35, 95% confidence interval: 0.77-1.93)]. CONCLUSIONS: The EuroSCORE II has better discriminative power for predicting operative mortality in ATAAD surgery than the GERAADA score. Both scores confirmed good calibration ability.


Assuntos
Dissecção Aórtica , Dissecção Aórtica/cirurgia , Coração , Mortalidade Hospitalar , Humanos , Curva ROC , Sistema de Registros , Medição de Risco , Fatores de Risco
3.
Asian Cardiovasc Thorac Ann ; 29(9): 903-909, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33611947

RESUMO

BACKGROUND: Total arterial revascularization is the most durable and technically the most demanding type of coronary artery bypass grafting procedure. It has proven long-term supremacy in comparison to conventional coronary artery bypass grafting. In our study, we investigated the reliability of EuroSCORE II as a predictor of intrahospital death. We showed its impact on adverse perioperative events. METHODS: In this nonrandomized prospective study, we analyzed 116 consecutive patients who underwent the total arterial revascularization procedure at our Institute from January 2011 until the present. For myocardial revascularization, the most suitable combinations with left internal mammary artery, right internal mammary artery, and radial artery grafts were used. Main fact in this research was intrahospital mortality value in comparison with the value predicted. RESULTS: There were 104 (89.7%) males and 12 (10.3%) females. Mean preoperative EuroSCORE II prediction value was 1.98% and postoperative we obtained 1.72%. Postoperative redo for bleeding was 6%. Positive correlation was proven between the EuoroSCORE II value and intensive care unit stay (0.452; p < 0.001). Among patients who received two internal mammary arteries, the highest EuroSCORE II was among those with presternal wound infection (p = 0.005). Patients with bilateral internal mammary arteries and diabetes showed that they have the highest values of EuroSCORE II and, at the same time, that they are extremely prone to wound problems. CONCLUSIONS: We achieved a lower intrahospital mortality level than it was predicted with preoperative EuroSCORE II value. This tool is a reliable method for preoperative death risk calculation in this group of patients.


Assuntos
Artéria Torácica Interna , Ponte de Artéria Coronária , Feminino , Humanos , Masculino , Artéria Torácica Interna/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...