Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Vet Sci ; 11: 1401130, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962701

RESUMO

Introduction: Surgical glove use may be associated with a decrease in tactile sensitivity, with thicker gloves or double-gloving techniques further altering sensation. This study evaluates digital tactile sensitivity by use of a Grating Orientation Task (GOT) with multiple sterile gloving techniques (no gloves, single standard gloving, double standard gloving, orthopedic gloves, and micro-thickness gloves). Methods: Each participant performed the GOT at increasing grating widths until correctly noting orientation in ≥8 of 10 trials with multiple glove types or double-gloving technique. Glove order was randomly assigned and participants were blinded to the orientation and dome size. Results: All gloves except micro-thickness gloves showed increased threshold sensitivity values (i.e. worse fingertip sensitivity) when compared to control (micro:control, p = 0.105, others:control, p < 0.05). Single-layer gloves showed no significant difference in sensitivity when compared to orthopedic (p = 0.06) or double-layer latex gloves (p = 0.26). Discussion: Standard latex gloves decreased fingertip sensitivity when evaluated with the GOT. Double-layer and orthopedic latex gloves do not decrease sensitivity when compared with single-layer gloving. Micro-thickness gloves may provide similar tactile sensitivity to no surgical glove.

2.
Am J Vet Res ; : 1-10, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38862009

RESUMO

OBJECTIVE: To evaluate the feasibility of endoscopic inspection of thoracolumbar and lumbar pedicle tracts in a canine large-breed model and its accuracy for the detection of breached versus nonbreached tracts. ANIMALS: 2 greyhound cadavers. METHODS: CT scans of 2 greyhound cadavers from the sixth thoracic vertebra to the sacrum were obtained. Fifty-six pedicles were randomized to have drill tracts with different modified Zdichavsky grades (nonbreached, partial/full medial breach, or partial/full lateral breach) using 3-D-printed guides. Endoscopy was performed on a single occasion from October 9 to 10, 2023, using a 1.9-mm 0-degree needle arthroscope in a randomized blinded fashion. The grading of drill tracts was performed on postoperative CT. Specificity, sensitivity, positive and negative predictive values, and time to assign endoscopic grade were investigated. RESULTS: Postoperative CT confirmed 43 nonbreached tracts, 7 medial breaches (partial/full), and 5 lateral breaches (partial/full). One tract was excluded because of guide misplacement. Intraosseous endoscopy was successfully performed in the remaining 55 drill tracts. Sensitivity to detect medial and lateral breaches was 71.4% and 60.0%. Negative predictive value was 93.1%. Specificity was 94.2%. Positive predictive value for detection of medial and lateral breaches was 83.3% and 54.5%. Median (range) time to assign an endoscopic grade was 118 (30 to 486) seconds. CLINICAL RELEVANCE: Intraosseous endoscopy of pedicle drill tracts may be a useful adjunct technique during pedicle screw/pin placement in dogs.

3.
Front Vet Sci ; 10: 1281063, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38149296

RESUMO

A 7-year-old, 7.5 kg, female spayed dachshund dog presented to a veterinary teaching hospital after being referred for lameness and the inability to urinate. The dog presented as weakly ambulatory paraparetic with intact pain perception. Computed tomographic (CT) imaging showed ventral bony lysis and periosteal proliferation of the L3 vertebra, consistent with a plasma cell tumor. A corpectomy of the L3 vertebra was performed and subsequently stabilized with autogenous cortico-cancellous iliac crest bone staves, autogenous cancellous bone, and bilaterally placed locking plates [String of Pearls (SOP®), Orthomed]. The dog recovered well, with no decrease in neurologic status overnight, and continued to improve until discharge. Upon a recheck exam at 4 weeks postoperatively, the dog appeared neurologically improved with only mild ambulatory proprioceptive ataxia of the hind limbs. This case demonstrates that the transposition of a non-vascularized iliac crest autogenous bone graft with stabilization via SOP® plates and screws can be used in the management of dogs with vertebral plasma cell tumors and should be considered as a surgical option in similarly affected cases.

4.
Vet Surg ; 52(5): 648-660, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37071824

RESUMO

OBJECTIVE: To compare pin placement accuracy, intraoperative technique deviations, and duration of pin placement for pins placed by free-hand probing (FHP) or 3D-printed drill guide (3DPG) technique. SAMPLE POPULATION: Four greyhound cadavers. METHODS: Computed tomography (CT) examinations from T6-sacrum were obtained for determination of optimal pin placement and 3DPG creation. Two 3.2/2.4-mm positive profile pins were inserted per vertebra, one left and one right from T7-L7 (FHP [n = 56]; 3DPG [n = 56]) by one surgeon and removed for repeat CT. Duration of pin placement and intraoperative deviations (unanticipated deviations from planned technique) were recorded. Pin tracts were graded by two blinded observers using modified Zdichavsky classification. Descriptive statistics were used. RESULTS: A total of 54/56 pins placed with 3DPGs were assigned grade I (optimal placement) compared with 49/56 pins using the FHP technique. A total of 2/56 pins placed with 3DPGs and 3/56 pins using the FHP technique were assigned grade IIa (partial medial violation). A total of 4/56 pins placed using the FHP technique were assigned grade IIIa (partial lateral violation). No pins were assigned grade IIb (full medial violation). Intraoperative technique deviations occurred with 6/56 pins placed using the FHP technique and no pins with 3DPGs. Overall, pins were placed faster (mean ± SD 2.6 [1.3] vs. 4.5 [1.8] min) with 3DPGs. CONCLUSIONS: Both techniques were accurate for placement of spinal fixation pins. The 3DPG technique may decrease intraoperative deviations and duration of pin placement. CLINICAL RELEVANCE: Both techniques allow accurate pin placement in the canine thoracolumbar spine. The FHP technique requires specific training and has learning curve, whereas 3DPG technique requires specific software and 3D printers.


Assuntos
Pinos Ortopédicos , Fixação de Fratura , Cães , Animais , Pinos Ortopédicos/veterinária , Fixação de Fratura/métodos , Fixação de Fratura/veterinária , Tomografia Computadorizada por Raios X/veterinária , Impressão Tridimensional
5.
Vet Surg ; 52(2): 249-256, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36382668

RESUMO

OBJECTIVE: The objective of this study was to evaluate the use of linear external skeletal fixation (ESF) applied using minimally invasive techniques in dogs and cats. STUDY DESIGN: Retrospective study. ANIMALS: Forty-nine dogs and 6 cats. METHODS: Medical records of cases with nonarticular tibial fractures, repaired using linear ESF at a single academic institution between July 2010 and 2020, were reviewed. All records of cases that had nonarticular tibial fractures repaired using linear ESF were included. Information was collected regarding signalment, surgical procedures performed, perioperative care, radiographic evaluation, and postoperative complications. RESULTS: Intraoperative imaging was used in 40/55 (72%) of cases. Tibal plateau angle (TPA), tibial mechanical medial proximal and distal tibial angles (mMPTA and mMDTA, respectively) were not affected by intraoperative imaging (P = .344, P = .687, P = .418). A total of 22 (40%) complications occurred. Of these, 18 were considered minor and 4 were considered major. Open fractures had more major complications than closed fractures (P = .019). All fractures reached radiographic union of the fracture. The mean ± SD time to external fixator removal was 71 ± 48 days. CONCLUSION: Linear ESF applied using minimally invasive techniques with or without intraoperative imaging was an effective treatment for nonarticular tibial fractures. CLINICAL SIGNIFICANCE: Closed application of linear ESF should be considered as a minimally invasive option for stabilizing nonarticular tibial fractures.


Assuntos
Doenças do Gato , Doenças do Cão , Fraturas da Tíbia , Gatos , Cães , Animais , Estudos Retrospectivos , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/cirurgia , Placas Ósseas/veterinária , Doenças do Cão/cirurgia , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/veterinária , Fixação de Fratura/veterinária , Fixadores Externos/veterinária , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
6.
Front Vet Sci ; 9: 1011983, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36619957

RESUMO

Traction was used to diagnose instability of a T5-T6 traumatic luxation that was stabilized with locking plates in the laminae and dorsal pedicles. A two-year-old, 27 kg, female spayed golden retriever was presented to a veterinary teaching hospital after being referred for possible mandibular and spinal fractures after being hit by a car. The dog presented non-ambulatory paraparetic with intact pain perception. Computed tomographic (CT) imaging showed a fifth and sixth thoracic vertebral fracture/luxation, with and without manual traction. Surgical stabilization of the spine was performed with bilateral dorsally placed locking plates (String-of-Pearls, Orthomed, UK) in the laminae and dorsal aspects of the vertebral pedicles. The dog recovered well, and neurologic status improved significantly overnight and continued to improve up until discharge, which was 6 days postoperatively. Upon recheck exam at 8 weeks postoperatively, the dog appeared neurologically normal with no obvious surgical complications. This case demonstrates that diagnostic traction-the process of pulling, during imaging, on the dog's pelvis while the forelimbs are secured in extension-demonstrated instability of the spine which was not readily apparent on initial CT imaging. Additionally, the dorsal locking plate stabilization is a viable fixation option that provided acceptable stabilization of the mid-thoracic vertebrae.

7.
Vet Surg ; 50(7): 1427-1433, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34251686

RESUMO

OBJECTIVE: Identify acceptable implant corridors in the normal canine thoracic vertebrae (T) from T1 to T9. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Computed tomographic (CT) studies of normal canine thoracic spines (n = 39). METHODS: CT imaging studies of normal T1-T9 canine spines were evaluated by five independent observers. Each identified a proposed corridor, measured the width, length, and angle off mid-sagittal that the corridor occupied. RESULTS: CT studies were from 39 dogs weighing 3.19-60 kg (mean 10.72, SD 9.9 kg). Vertebral corridors ranged in average width from 3.8 to 5.2 mm, the widest being located at T1. They ranged in average length from 13.3 to 17.5 mm, shortest being T1 and longest being T6. The angle of corridors varied the most between individual vertebrae at T1-T3. The average corridor angles were: T1 = 38°, T2 = 32°, T3 = 27°, T4 = 26°. T5-T9 angle ranged from 23° to 24°. CONCLUSION: The average dimensions of corridors measured in dogs weighing 3.1-60 kg were consistent with those of commercially available cortical screws and pins. CLINICAL SIGNIFICANCE: Corridor trajectories identified in this population can be achieved from a dorsal approach between T5 and T9. A dorsal approach for implant placement would be challenging for T1-T4 due to the variability found in these vertebrae as well as regional anatomical constraints.


Assuntos
Vértebras Torácicas , Tomografia Computadorizada por Raios X , Animais , Pinos Ortopédicos , Cães , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/veterinária
8.
Vet Surg ; 50(6): 1296-1303, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34076285

RESUMO

OBJECTIVE: To determine the influence of suture patterns on resistance to gap formation after tendon plating STUDY DESIGN: Ex vivo study SAMPLE POPULATION: Suspensory ligament and superficial and deep digital flexor tendons harvested from 16 neonatal cadaver foal limbs. METHODS: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 mm gap for initial failure and a 3 mm gap for ultimate failure. The mode of failure was also recorded. RESULTS: Constructs prepared with hybrid and figure-8 patterns sustained over 2× higher (p < .01) forces before gap formation compared to those prepared with a simple interrupted pattern. No difference was identified between tendons whose plate was secured with hybrid or figure-8 suture patterns. Mode of failure between groups did not differ. CONCLUSION: The figure-8 and hybrid patterns described herein improved the resistance to gap formation of plated tendons compared to an alternating simple interrupted pattern described previously. CLINICAL SIGNIFICANCE: Figure-8 and hybrid patterns should be considered over simple interrupted patterns to improve resistance to gap formation in horses undergoing tendon plating.


Assuntos
Doenças dos Cavalos , Traumatismos dos Tendões , Animais , Fenômenos Biomecânicos , Cadáver , Doenças dos Cavalos/cirurgia , Cavalos , Testes Mecânicos , Técnicas de Sutura/veterinária , Suturas/veterinária , Traumatismos dos Tendões/cirurgia , Traumatismos dos Tendões/veterinária , Tendões/cirurgia , Resistência à Tração
9.
Vet Surg ; 50(5): 1076-1086, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33955036

RESUMO

OBJECTIVE: To determine the influence of plating systems on the clinical outcomes in dogs treated for ilial fractures. DESIGN: Retrospective study. ANIMALS: Fifty-nine dogs (63 hemipelves). METHODS: Radiographs and medical records of dogs with ilial fractures presented to Iowa State University between 2003 and 2019 were reviewed. After fracture reduction, fractures were fixed with a locking plate system (LPS) or non-locking plate system (NLS). Perioperative, long-term complications, and follow-up data were recorded. The frequency of implant failure and pelvic collapse were compared using a logistic and linear regression analysis, respectively. Where the univariate test was statistically significant, a multivariate analysis across categories was performed to identify statistically different categories. RESULTS: LPS and NLS implants were used in 25/63 and 38/63 hemipelves, respectively. Median follow-up time was 8 weeks (3-624 weeks). Implant failure occurred in 18/63 (29%) of fracture repairs, consisting of 17 with NLS and 1 with LPS. Revision surgery was recommended in five cases of implant failure, all with NLS. The probability of implant failure was higher when fractures were fixed with NLS (p = .0056). All other variables evaluated did not seem to influence outcome measures. CONCLUSION: The variable with the most influence on the outcomes of dogs treated for ilial fractures consisted of the fixation method (NLS vs. LPS). Fractures repaired with NLS were nearly 20 times more likely to fail than those repaired with LPS. CLINICAL RELEVANCE: Surgeons should consider repairing ilial body fractures in dogs with LPS to reduce the risk of short-term implant failure.


Assuntos
Placas Ósseas/veterinária , Doenças do Cão/cirurgia , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Ílio/lesões , Animais , Cães , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Ílio/cirurgia , Masculino , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
10.
Vet Surg ; 50(5): 1065-1075, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33955568

RESUMO

OBJECTIVE: To determine radiation exposure to surgical personnel and to evaluate the accuracy of a modified percutaneous lag screw fixation technique for sacroiliac luxation (SIL) under fluoroscopic guidance in dogs. STUDY DESIGN: Cadaveric experimental study. SAMPLE POPULATION: Seventeen beagle cadavers with iatrogenic SIL. METHODS: Seventeen beagles with iatrogenic SIL underwent reduction and stabilization with 3.5-mm screws. Hypodermic needles (14 gauge) and fluoroscopy were used to orient two Kirschner wires for temporary stabilization and to guide drilling of glide and pilot holes using cannulated drill bits. Duration of surgery and radiation exposure were recorded. Postoperative computed tomographic evaluation of screw position and angulation was performed. RESULTS: Average time for fixation was 15.85 minutes (range, 6.37-33.5). Cumulative radiation doses of 0.4 mrem for the dominant arm of the assistant and 0 mrem for the primary surgeon were recorded. The mean dorsoventral and craniocaudal screw angles were 0.68° ± 3.4° (range - 5.4° to 9.5°) and 1.9° ± 3.2° (range - 4.3° to 9.1°), respectively. Sixteen of the 17 dogs had 100% sacral screw purchase, with the remaining case achieving 93.4% purchase. CONCLUSION: Fluoroscopy-assisted percutaneous placement of 3.5-mm cortical screws in lag fashion performed with 14-gauge needles in conjunction with Kirschner wires and cannulated drill bits yielded repeatable accurate screw placement with low levels of ionizing radiation exposure to the surgical team. CLINICAL SIGNIFICANCE: The described technique may be a viable method for minimally invasive osteosynthesis fixation of SIL with low levels of radiation exposure to the surgical team. These results provide evidence to support further evaluation of radiation exposure in clinical cases and can aid in study design and sample size determination.


Assuntos
Doenças do Cão/cirurgia , Fluoroscopia/veterinária , Fixação Interna de Fraturas/veterinária , Luxações Articulares/veterinária , Exposição à Radiação , Articulação Sacroilíaca , Animais , Parafusos Ósseos/veterinária , Cadáver , Cães , Fixação Interna de Fraturas/métodos , Tomografia Computadorizada por Raios X
11.
J Mech Behav Biomed Mater ; 116: 104345, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33561675

RESUMO

A tunable stiffness bone rod was designed, optimized, and 3D printed to address the shortcomings of existing bone fixation devices, such as stress shielding and bone nonunion in the healing of fractured bones. Current bone plates/rods have constant and high stiffness. High initial stiffness prevents the micromotion of newly formed bone and results in poor bone healing. Our novel design framework provides surgeons with a ready-for-3D-printing, patient-specific design, optimized to have the desired force-displacement response with a stopping mechanism for preventing further deformation under higher-than-normal loads, such as falling. The computational framework is a design optimization based on the multi-objective genetic algorithm (GA) optimization with the FE simulation to quantify the objectives: tuning the varied stiffness while minimizing the maximum von Mises stress of the model to avoid plastic and permanent deformation of the bone rod. The computational framework for optimum design of tunable stiffness metamaterial presented in this paper is not specific for a tibia bone rod, and it can be used for any application where bilinear stiffness is desirable.


Assuntos
Placas Ósseas , Fraturas Ósseas , Análise de Elementos Finitos , Humanos , Fenômenos Mecânicos , Tíbia
12.
Front Vet Sci ; 7: 567886, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33521073

RESUMO

The objective of this case report was to describe successful surgical and post-operative management of a medial patellar luxation in a Vietnamese Potbellied Pig. A two-year old, castrated, Vietnamese Potbellied Pig presented to a veterinary teaching hospital for right pelvic limb lameness of 2 weeks duration. Upon physical examination a grade 3 patellar luxation was diagnosed on the right pelvic limb. Surgical repair included a trochlear wedge sulcoplasty, tibial tuberosity transposition, and lateral imbrication as described for canine patellar luxation. The pig was managed post-operatively with meloxicam and a physical therapy regimen of seven weeks duration. At recheck examination the pig was sound, no complications were observed, and the owners were satisfied with the outcome. As miniature companion pigs, such as Vietnamese Potbellied Pigs are currently increasing in popularity as pets, this case demonstrated that comparative techniques from other veterinary species should be considered when considering a treatment plan for a pig with a medial patellar luxation.

13.
Vet Comp Orthop Traumatol ; 32(6): 440-446, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31279325

RESUMO

OBJECTIVE: The aim of this study was to to determine the comparative stiffness following repair of an axial sagittal fracture model in equine distal sesamoid bones using either a single 3.5-mm or 4.5-mm cortical bone screw placed in lag fashion. STUDY DESIGN: The present study was an in vitro biomechanical study. RESULTS: The mean (±standard deviation) stiffness value for the 4.5-mm screw-bone construct (522.49 N/mm ± 168.21) was significantly greater than the 3.5-mm screw-bone construct (408.46 N/mm ± 131.13) (p = 0.047). This represents a 28% difference in mean stiffness. CONCLUSIONS: In vitro, the 4.5-mm screw-bone construct creates a stiffer repair of fractured distal sesamoid bones by a margin of 28%. The 4.5-mm cortical bone screw may better withstand forces imparted on the distal sesamoid bone sustained during anaesthetic recovery, normal weight bearing and athletic exercise, thereby minimizing the risk of implant failure.


Assuntos
Parafusos Ósseos/veterinária , Fraturas Ósseas/veterinária , Cavalos/lesões , Ossos Sesamoides/lesões , Animais , Fenômenos Biomecânicos , Parafusos Ósseos/classificação , Membro Anterior , Fraturas Ósseas/cirurgia , Membro Posterior , Cavalos/cirurgia , Ossos Sesamoides/patologia , Ossos Sesamoides/cirurgia
14.
Vet Surg ; 48(8): 1450-1455, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30951203

RESUMO

OBJECTIVE: To determine the influence of plate fixation (locking or dynamic compression) and the site of application (ventral [V] or ventrolateral [VL]) on the resistance to bending of transverse mandibular fractures. STUDY DESIGN: Ex vivo, simple randomized study. SAMPLE POPULATION: Mandibles harvested from adult equine cadavers (n = 18). METHODS: Bilateral osteotomies were created 1 cm caudal to the mental foramen and perpendicular to the long axis of each mandible. Mandibles were fixed with 1 of 3 methods: (1) VL dynamic compression plate (DCP), (2) V-DCP, or (3) VL locking compression plating (LCP). Constructs were mounted on a custom testing jig and tested for resistance in bending by applying force to the rostral aspect of the mandible. Stiffness and change of distance of the dorsal osteotomy at 200 N were compared among constructs. RESULTS: VL-LCP constructs were 5.25 and 2.42 times stiffer than V and VL constructs, respectively (P<.001). Change in the width of the osteotomy gap at 200 N of load was reduced 6.04 times when osteotomies were stabilized with VL compared to V (P<.001); no difference was detected between the VL and VL-LCP constructs (P=.836). CONCLUSION: Ventrolateral LCP fixation of equine transverse mandibular osteotomies provided greater resistance to bending compared with V and VL constructs. CLINICAL SIGNIFICANCE: These results provide evidence to recommend fixation of transverse interdental mandibular fractures with VL-LCP rather than with DCP in horses.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Cavalos/cirurgia , Fraturas Mandibulares/veterinária , Osteotomia Mandibular/veterinária , Animais , Fenômenos Biomecânicos , Cadáver , Fraturas Mandibulares/cirurgia , Osteotomia Mandibular/métodos
15.
BMC Vet Res ; 15(1): 40, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30683098

RESUMO

BACKGROUND: Suture materials and techniques are frequently evaluated in ex vivo studies by comparing tensile strengths. However, the direct measurement techniques to obtain the tensile forces in canine skin are not available, and, therefore, the conditions suture lines undergo is unknown. A soft elastomeric capacitor is used to monitor deformation in the skin over time by sensing strain. This sensor was applied to a sample of canine skin to evaluate its capacity to sense strain in the sample while loaded in a dynamic material testing machine. The measured strain of the sensor was compared with the strain measured by the dynamic testing machine. The sample of skin was evaluated with and without the sensor adhered. RESULTS: In this study, the soft elastomeric capacitor was able to measure strain and a correlation was made to stress using a modified Kelvin-Voigt model for the canine skin sample. The sensor significantly increases the stiffness of canine skin when applied which required the derivation of mechanical models for interpretation of the results. CONCLUSIONS: Flexible sensors can be applied to canine skin to investigate the inherent biomechanical properties. These sensors need to be lightweight and highly elastic to avoid interference with the stress across a suture line. The sensor studied here serves as a prototype for future sensor development and has demonstrated that a lightweight highly elastic sensor is needed to decrease the effect on the sensor/skin construct. Further studies are required for biomechanical characterization of canine skin.


Assuntos
Técnicas Biossensoriais/veterinária , Pele , Animais , Fenômenos Biomecânicos , Técnicas Biossensoriais/instrumentação , Cães , Elastômeros/química , Estresse Mecânico , Suturas/veterinária
16.
Vet Surg ; 47(3): 439-444, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29393973

RESUMO

OBJECTIVE: To report the application of a plate to treat a complicated calcaneal tendon rupture and the resulting outcome. STUDY DESIGN: Clinical case report. ANIMALS: A 3-year-old Labrador retriever. METHODS: A 3-year-old Labrador retriever was treated for a partially ruptured calcaneal tendon. Two primary tendon repairs with sutures and external fixation had failed. A veterinary cuttable plate was placed to internally span the tendon over the primary repair. The external fixation that had been previously placed was maintained, and the dog was placed in a non-weight-bearing sling for 3 weeks after surgery. Adjunct therapy included an injection of platelet-rich plasma in the tendon and laser therapy. The external fixator was removed 4 weeks postoperatively, and the plate was removed 8 weeks postoperatively. RESULTS: A mature fibrous union bridged the site of anastomosis 8 weeks after surgery. The owners reported normal activity 6 months after surgery and symmetric hock angles and musculature 2 years after surgery. CONCLUSION: Adjunct plating of previously failed calcaneal tendon repairs in a dog resulted in an excellent long-term outcome. CLINICAL SIGNIFICANCE: Plating tendons can be considered as an additional method that may improve tendon apposition and decrease gap formation.


Assuntos
Tendão do Calcâneo/lesões , Cães/lesões , Traumatismos dos Tendões/veterinária , Tendão do Calcâneo/cirurgia , Animais , Placas Ósseas/veterinária , Cães/cirurgia , Fixadores Externos/veterinária , Masculino , Ruptura/cirurgia , Ruptura/veterinária , Suturas/veterinária , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/cirurgia
17.
J Am Vet Med Assoc ; 248(12): 1377-82, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27270059

RESUMO

OBJECTIVE To compare suture placement time, tension at skin separation and suture line failure, and mode of failure among 4 suture patterns. DESIGN Randomized trial. SAMPLE 60 skin specimens from the pelvic limbs of 30 purpose-bred Beagles. PROCEDURES Skin specimens were harvested within 2 hours after euthanasia and tested within 6 hours after harvest. An 8-cm incision was made in each specimen and sutured with 1 of 4 randomly assigned suture patterns (simple interrupted, cruciate, intradermal, or subdermal). Suture placement time and percentage of skin apposition were evaluated. Specimens were mounted in a calibrated material testing machine and distracted until suture line failure. Tensile strength at skin-edge separation and suture-line failure and mode of failure were compared among the 4 patterns. RESULTS Mean suture placement time for the cruciate pattern was significantly less than that for other patterns. Percentage of skin apposition did not differ among the 4 patterns. Mean tensile strength at skin-edge separation and suture-line failure for the simple interrupted and cruciate patterns were significantly higher than those for the intradermal and subdermal patterns. Mean tensile strength at skin-edge separation and suture-line failure did not differ significantly between the intradermal and subdermal patterns or the simple interrupted and cruciate patterns. The primary mode of failure for the simple interrupted pattern was suture breakage, whereas that for the cruciate, intradermal, and subdermal patterns was tissue failure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested external skin sutures may be preferred for closure of incisions under tension to reduce risk of dehiscence.


Assuntos
Cães , Pele , Técnicas de Sutura/veterinária , Animais , Fenômenos Biomecânicos , Cadáver , Resistência à Tração
18.
J Am Vet Med Assoc ; 248(4): 386-94, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26829270

RESUMO

OBJECTIVE: To investigate associations between recovery of locomotion and putative prognostic factors in dogs with loss of deep pain perception in the pelvic limbs caused by intervertebral disk herniation (IVDH). DESIGN: Prospective cohort study. ANIMALS: 78 client-owned dogs evaluated for IVDH that underwent spinal decompression surgery. PROCEDURES: Dogs with complete loss of deep pain perception in the pelvic limbs and tail underwent routine examinations, advanced imaging, and spinal decompression surgery in accordance with standards of practice and owner consent. For each dog, information was prospectively collected on duration of clinical signs prior to onset of paraplegia; delay between onset of paraplegia and initial referral evaluation; date of recovery of locomotion, death, or euthanasia (3-month follow-up period); and whether dogs had received corticosteroid drugs before surgery. Severity of spinal cord compression at the lesion epicenter was measured via CT or MRI. RESULTS: 45 of 78 (58%) of dogs recovered the ability to ambulate independently within 3 months after spinal decompression surgery. No evidence of prognostic value was identified for any of the investigated factors; importantly, a greater delay between onset of paraplegia and referral evaluation was not associated with a poorer prognosis. CONCLUSIONS AND CLINICAL RELEVANCE: In this group of dogs with IVDH, immediacy of surgical treatment had no apparent association with outcome. The prognosis for recovery may instead be strongly influenced by the precise nature of the initiating injury.


Assuntos
Doenças do Cão/fisiopatologia , Deslocamento do Disco Intervertebral/veterinária , Locomoção/fisiologia , Percepção da Dor/fisiologia , Paraplegia/veterinária , Compressão da Medula Espinal/veterinária , Animais , Estudos de Coortes , Descompressão Cirúrgica/veterinária , Doenças do Cão/cirurgia , Cães , Deslocamento do Disco Intervertebral/fisiopatologia , Deslocamento do Disco Intervertebral/cirurgia , Paraplegia/fisiopatologia , Paraplegia/cirurgia , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Compressão da Medula Espinal/complicações , Compressão da Medula Espinal/diagnóstico , Resultado do Tratamento
19.
Vet Surg ; 44(1): 65-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24962167

RESUMO

OBJECTIVE: To compare 2-0 polyglyconate barbed suture (V-LOC™ 180 Absorbable Wound Closure Device, Covidien, Mansfield, MA) to standard 2-0 monofilament absorbable polyglyconate suture (Maxon™, Covidien) for maximum load to failure and failure mode when used to appose standardized defects in canine diaphragm muscle. STUDY DESIGN: Randomized, cadaveric ex vivo mechanical testing. SAMPLE POPULATION: Canine cadaveric hemi-diaphragmatic specimens (n = 32 pairs). METHODS: Thirty-two cadaveric diaphragm specimens were collected and divided to obtain 64 muscle specimens (9 cm × 4 cm). Paired specimens were bisected in the midpoint of their 9 cm length in the direction of the muscle fibers and apposed using either 2-0 polyglyconate or 2-0 barbed polyglyconate (V-LOC™ 180 Absorbable Wound Closure Device) in a simple continuous pattern. Increasing tension was applied perpendicular to the suture line until specimen failure. Failure mode and maximum load to failure were recorded for each specimen. RESULTS: Mean ± SD failure load of simulated herniorrhaphies performed with barbed polyglyconate suture (54.5 ± 10.27 N) was not significantly different than repair with polyglyconate (56.9 ± 10.87 N). Failure mode for both construct types was suture tear out rather than suture failure. CONCLUSIONS: Clinical application of 2-0 barbed polyglyconate suture can be considered as an alternative to the use of 2-0 polyglyconate for diaphragmatic herniorrhaphy.


Assuntos
Cães/cirurgia , Herniorrafia/veterinária , Suturas , Animais , Fenômenos Biomecânicos , Cadáver , Herniorrafia/métodos , Modelos Animais , Polímeros
20.
J Am Anim Hosp Assoc ; 48(6): 372-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23033465

RESUMO

Locking plates have been shown to offer improved fixation in fractures involving either osteoporotic bone or bone with lesser screw pullout strength, such as thin and flat bones. Fractures of the scapular body are one type of fracture where the screw pullout strength using conventional plate fixation may not be sufficient to overcome physiologic forces. The purpose of this study was to compare the pullout strengths of locking plates to conventional nonlocking plates in the canine scapula. A 2.7 mm string of pearls plate (SOP) and a 2.7 mm limited contact dynamic compression plate (LC-DCP) were applied with similar divergent screws to the supraspinatus fossa of the scapula. Forces perpendicular to the plates were applied and both the loads at failure and modes of failure were recorded. No differences were noted in loads at failure between the two plating systems. Although the modes of failure were not significantly different, the SOP constructs tended to fail more often by bone slicing and coring, whereas the LC-DCP constructs failed primarily by screw stripping. Neither of the plate systems used in this study demonstrated a distinct mechanical advantage. The application and limitations of locking plate systems in various clinical situations require further study.


Assuntos
Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Teste de Materiais/veterinária , Escápula , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Cães/lesões , Cães/cirurgia , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Masculino , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Escápula/cirurgia , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...