1.
Europace ; 10(8): 907-13, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18515789

RESUMO

AIMS: We evaluated the feasibility of the TULIP (Threshold test using Upper Limit during ImPlantation) protocol, which was designed to provide a confirmed, low defibrillation energy value during implantable cardioverter defibrillator (ICD) implantation with only two induced ventricular fibrillation (VF) episodes. METHODS AND RESULTS: Ninety-eight patients (62 +/- 12 years, 86 male) from 13 clinical centres underwent an active can ICD implantation. A single coupling interval derived from electrocardiogram lead II during ventricular pacing was used for VF induction shocks at 13, 11, 9, and 6 J in a step-down manner until the upper limit of VF induction (ULVI) was determined. If ULVI >or=9 J, a defibrillation energy of ULVI + 4 J was tested. For ULVI <9 J, the defibrillation test energy was 9 J. In 79/98 patients (80.6%), two induced VF episodes were sufficient to obtain confirmed defibrillation energy of 11.1 +/- 3.3 J. The mean strength of the successful VF induction shock was 6.8 +/- 4.3 J, the coupling interval was 303 +/- 35 ms, and the number of delivered induction shocks until the first VF induction was 3.9 +/- 1.6. CONCLUSION: TULIP is a safe and simple device testing procedure allowing the determination of confirmed, low defibrillation energy in most patients with two VF episodes induced at a single coupling interval.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Análise de Falha de Equipamento/métodos , Terapia Assistida por Computador/métodos , Fibrilação Ventricular/reabilitação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
2.
Europace ; 10(6): 729-35, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18434298

RESUMO

AIMS: With the expanding indications for implantable cardioverter defibrillator (ICD) and reports of unexpected ICD failures, home monitoring (HM) was proposed to decrease follow-up workload and increase patient safety. Home monitoring implantable cardioverter defibrillators offer wireless, everyday transfer of ICD status and therapy data to a central HM Service Center, which notifies the attending physician of relevant HM events. We evaluated functionality and safety of HM ICDs. METHODS AND RESULTS: A total of 260 patients with HM ICDs were monitored for a mean of 10 +/- 5 months. Time to HM events [medical (ventricular tachycardia/ventricular fibrillation) and technical (ICD system integrity)] since ICD implantation and since the latest in-clinic follow-up was analysed. Mean number of HM events per 100 patients per day was calculated, without and with a 2-day blanking period for re-notifying the same type of event. About 41.2% of the patients had HM events (38.1% medical, 0.8% technical, and 2.3% both types). Probability of any HM event after 1.5 years was 0.50 (95% confidence interval: 0.42-0.58). More than 60% of new HM event types occurred within the first month after follow-up. A mean of 0.86 event notifications was received per 100 patients per day or 0.45 with the 2-day blanking period. CONCLUSION: Home monitoring is feasible and associated with an early detection of medical and technical events.


Assuntos
Desfibriladores Implantáveis , Análise de Falha de Equipamento/métodos , Telemedicina/métodos , Telemetria/métodos , Terapia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos de Viabilidade , Feminino , Serviços de Assistência Domiciliar , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade