Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 39(4): 713-719, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29472302

RESUMO

BACKGROUND AND PURPOSE: Aneurysm volume pulsation is a potential predictor of intracranial aneurysm rupture. We evaluated whether 7T MR imaging can quantify aneurysm volume pulsation. MATERIALS AND METHODS: In Stage I of the study, 10 unruptured aneurysms in 9 patients were studied using a high-resolution (0.6-mm, isotropic) 3D gradient-echo sequence with cardiac gating. Semiautomatic segmentation was used to measure aneurysm volume (in cubic millimeters) per cardiac phase. Aneurysm pulsation was defined as the relative increase in volume between the phase with the smallest volume and the phase with the largest volume. The accuracy and precision of the measured volume pulsations were addressed by digital phantom simulations and a repeat image analysis. In Stage II, the imaging protocol was optimized and 9 patients with 9 aneurysms were studied with and without administration of a contrast agent. RESULTS: The mean aneurysm pulsation in Stage I was 8% ± 7% (range, 2%-27%), with a mean volume change of 15 ± 14 mm3 (range, 3-51 mm3). The mean difference in volume change for the repeat image analysis was 2 ± 6 mm3. The artifactual volume pulsations measured with the digital phantom simulations were of the same magnitude as the volume pulsations observed in the patient data, even after protocol optimization in Stage II. CONCLUSIONS: Volume pulsation quantification with the current imaging protocol on 7T MR imaging is not accurate due to multiple imaging artifacts. Future studies should always include aneurysm-specific accuracy analysis.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil
2.
PLoS One ; 10(9): e0136710, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26366860

RESUMO

PURPOSE: Using three-dimensional (3D) stereophotogrammetry precise images and reconstructions of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT) data for precise planning and prediction of treatment outcome. Though, in hand surgery 3D stereophotogrammetry is not yet being used in clinical settings. METHODS: A total of 34 three-dimensional hand photographs were analyzed to investigate the reproducibility. For every individual, 3D photographs were captured at two different time points (baseline T0 and one week later T1). Using two different registration methods, the reproducibility of the methods was analyzed. Furthermore, the differences between 3D photos of men and women were compared in a distance map as a first clinical pilot testing our registration method. RESULTS: The absolute mean registration error for the complete hand was 1.46 mm. This reduced to an error of 0.56 mm isolating the region to the palm of the hand. When comparing hands of both sexes, it was seen that the male hand was larger (broader base and longer fingers) than the female hand. CONCLUSIONS: This study shows that 3D stereophotogrammetry can produce reproducible images of the hand without harmful side effects for the patient, so proving to be a reliable method for soft tissue analysis. Its potential use in everyday practice of hand surgery needs to be further explored.


Assuntos
Antropometria/métodos , Mãos/anatomia & histologia , Fotogrametria/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
J Plast Reconstr Aesthet Surg ; 68(5): 709-16, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25665488

RESUMO

BACKGROUND: Using three-dimensional (3D) photography, exact images of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT) data for accurate planning and prediction of treatment outcome. However, in hand surgery, 3D photography is not yet being used in clinical settings. METHODS: The aim of this study was to develop a valid method for imaging the hand using 3D stereophotogrammetry. The reproducibility of 30 soft tissue landmarks was determined using 3D stereophotogrammetric images. Analysis was performed by two observers on 20 3D photographs. Reproducibility and reliability of the landmark identification were determined using statistical analysis. RESULTS: The intra- and interobserver reproducibility of the landmarks were high. This study showed a high reliability coefficient for intraobserver (1.00) and interobserver reliability (0.99). Identification of the landmarks on the palmar aspect of individual fingers was more precise than the identification of landmarks of the thumb. CONCLUSIONS: This study shows that 3D photography can safely produce accurate and reproducible images of the hand, which makes the technique a reliable method for soft tissue analysis. 3D images can be a helpful tool in pre- and postoperative evaluation of reconstructive trauma surgery, in aesthetic surgery of the hand, and for educational purposes. The use in everyday practice of hand surgery and the concept of fusing 3D photography images with radiologic images of the interior hand structures needs to be further explored.


Assuntos
Mãos/anatomia & histologia , Mãos/cirurgia , Imageamento Tridimensional/métodos , Modelos Anatômicos , Fotogrametria/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Interpretação Estatística de Dados , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Postura , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...