1.
J Orthop Trauma
; 24(10): e83-5, 2010 Oct.
Artigo
em Inglês
| MEDLINE
| ID: mdl-20871241
RESUMO
We report on the case of a patient suffering from L5 radicular pain after previous anterior sacroiliac arthrodesis using 2, 4-hole plates. Technical investigations indicated loosening and migration of a screw from the upper sacroiliac plate, irritating the L5 nerve root. The problem was managed by removal of the screw using an anterior transperitoneal laparoscopic approach.