Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
J Am Heart Assoc ; 13(11): e033931, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38818962

RESUMO

BACKGROUND: Patients may prefer percutaneous coronary intervention (PCI) over coronary artery bypass graft (CABG) surgery, despite heart team recommendations. The outcomes in such patients have not been examined. We sought to examine the results of PCI in patients who were recommended for but declined CABG. METHODS AND RESULTS: Consecutive patients with stable ischemic heart disease and unprotected left main or 3-vessel disease or Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score >22 who underwent PCI after heart team review between 2013 and 2020 were included. Patients were categorized into 3 groups according to heart team recommendations on the basis of appropriate use criteria: (1) PCI-recommended; (2) CABG-eligible but refused CABG (CABG-refusal); and (3) CABG-ineligible. The primary end point was the composite of death, myocardial infarction, or stroke at 1 year. The study included 3687 patients undergoing PCI (PCI-recommended, n=1718 [46.6%]), CABG-refusal (n=1595 [43.3%]), and CABG-ineligible (n=374 [10.1%]). Clinical and procedural risk increased across the 3 groups, with the highest comorbidity burden in CABG-ineligible patients. Composite events within 1 year after PCI occurred in 55 (4.1%), 91 (7.0%), and 41 (14.8%) of patients in the PCI-recommended, CABG-refusal, and CABG-ineligible groups, respectively. After multivariable adjustment, the risk of the primary composite outcome was significantly higher in the CABG-refusal (hazard ratio [HR], 1.67 [95% CI, 1.08-3.56]; P=0.02) and CABG-ineligible patients (HR, 3.26 [95% CI, 1.28-3.65]; P=0.004) groups compared with the reference PCI-recommended group, driven by increased death and stroke. CONCLUSIONS: Cardiovascular event rates after PCI were significantly higher in patients with multivessel disease who declined or were ineligible for CABG. Our findings provide real-world data to inform shared decision-making discussions.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Masculino , Ponte de Artéria Coronária/efeitos adversos , Feminino , Idoso , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/mortalidade , Pessoa de Meia-Idade , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco , Medição de Risco , Seleção de Pacientes , Tomada de Decisão Clínica
2.
J Invasive Cardiol ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38776477

RESUMO

A 93-year-old woman with symptomatic severe aortic stenosis and normal biventricular function was referred for transcatheter aortic valve replacement (TAVR) evaluation. Cardiac computed tomography revealed safe coronary heights and multiple large calcified mobile mass-like structures attached to the aortic valve (AV), confirmed also by transesophageal echocardiography, which were thought to be prominent Lambl's excrescences.

3.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38456886

RESUMO

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Tomografia Computadorizada Multidetectores
4.
J Invasive Cardiol ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38547048

RESUMO

We report the case of an 80-year-old woman with known quadricuspid aortic valve (QAV), severe aortic stenosis, and moderate-to-severe regurgitation who recently underwent a transcatheter aortic valve replacement (TAVR).

5.
Circ Cardiovasc Interv ; 17(3): e013766, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38502723

RESUMO

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) can pin the index transcatheter heart valve leaflets open leading to sinus sequestration and restricting coronary access. The impact of initial implant depth and commissural alignment on redo-TAVR feasibility is unclear. We sought to determine the feasibility of redo-TAVR and coronary access after SAPIEN 3 (S3) TAVR stratified by implant depth and commissural alignment. METHODS: Consecutive patients with native valve aortic stenosis were evaluated using multidetector computed tomography. S3 TAVR simulations were done at 3 implant depths, sizing per manufacturer recommendation and assuming nominal expansion in all cases. Redo-TAVR was deemed unfeasible based on valve-to-sinotubular junction distance and valve-to-sinus height <2 mm, while the neoskirt plane of the S3 transcatheter heart valve estimated coronary access feasibility. RESULTS: Overall, 1900 patients (mean age, 80.2±8 years; STS-PROM [Society of Thoracic Surgeons Predicted Risk of Operative Mortality], 3.4%) were included. Redo-TAVR feasibility reduced significantly at shallower initial S3 implant depths (2.3% at 80:20 versus 27.5% at 100:0, P<0.001). Larger S3 sizes reduced redo-TAVR feasibility, but only in patients with a 100:0 implant (P<0.001). Commissural alignment would render redo-TAVR feasible in all patients, assuming the utilization of leaflet modification techniques to reduce the neoskirt height. Coronary access following TAV-in-TAV was affected by both index S3 implant depth and size. CONCLUSIONS: This study highlights the critical impact of implant depth, commissural alignment, and transcatheter heart valve size in predicting redo-TAVR feasibility. These findings highlight the necessity for individualized preprocedural planning, considering both immediate results and long-term prospects for reintervention as TAVR is increasingly utilized in younger patients with aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Fatores de Risco
7.
Open Heart ; 11(1)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191233

RESUMO

BACKGROUND: A quarter of patients with severe aortic stenosis (AS) were asymptomatic, and only a third of them survived at the end of 4 years. Only a select subset of these patients was recommended for aortic valve replacement (AVR) by the current American College of Cardiology/American Heart Association guidelines. We intended to study the effect of early AVR (eAVR) in this subset of asymptomatic patients with preserved left ventricle function. METHODS AND RESULTS: We searched PubMed and Embase for randomised and observational studies comparing the effect of eAVR versus conservative therapy in patients with severe, asymptomatic AS and normal left ventricular function. The primary outcome was all-cause mortality. The secondary outcomes were composite major adverse cardiac events (MACE) (study defined), myocardial infarction (MI), stroke, cardiac death, sudden death, the development of symptoms, heart failure hospitalisations and major bleeding. We used GRADEPro to assess the certainty of the evidence. In the randomised controlled trial (RCT) only analysis, we found no significant difference in all-cause mortality between the early aortic intervention group versus the conservative arm (CA) (incidence rate ratio, IRR (CI): 0.5 (0.2 to 1.1), I2=31%, p=0.09). However, in the overall cohort, we found mortality benefit for eAVR over CA (IRR (CI): 0.4 (0.3 to 0.7), I2=84%, p<0.01). There were significantly lower MACE, cardiac death, sudden death, development of symptoms and heart failure hospitalisations in the eAVR group. We noticed no difference in MI, stroke and major bleeding. CONCLUSION: We conclude that there is no reduction in all-cause mortality in the eAVR arm in patients with asymptomatic AS with preserved ejection fraction. However, eAVR reduces heart failure related hospitalisations and death or heart failure hospitalisations. PROSPERO REGISTRATION NUMBER: CRD42022306132.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Tratamento Conservador/efeitos adversos , Morte Súbita Cardíaca/etiologia , Insuficiência Cardíaca/etiologia , Hemorragia/etiologia , Infarto do Miocárdio/etiologia , Acidente Vascular Cerebral/etiologia , Estados Unidos , Função Ventricular Esquerda , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
Eur Heart J Cardiovasc Pharmacother ; 10(1): 11-19, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-37742213

RESUMO

AIM: To assess the value of the thrombotic risk criteria proposed in the 2023 guidelines of the European Society of Cardiology (ESC) for the management of acute coronary syndrome (ACS) to predict the ischaemic risk after percutaneous coronary intervention (PCI). METHODS AND RESULTS: Consecutive patients with acute or chronic coronary syndrome undergoing PCI at a large tertiary-care center from 2014 to 2019 were included. Patients were stratified into low, moderate, or high thrombotic risk based on the ESC criteria. The primary endpoint was major adverse cardiovascular events (MACEs) at 1 year, a composite of all-cause death, myocardial infarction (MI), and stroke. Secondary endpoints included major bleeding. Among 11 787 patients, 2641 (22.4%) were at low-risk, 5286 (44.8%) at moderate risk, and 3860 (32.7%) at high-risk. There was an incremental risk of MACE at 1 year in patients at moderate (hazard ratios (HR) 2.53, 95% confidence interval (CI) 1.78-3.58) and high-risk (HR 3.39, 95% CI 2.39-4.80) as compared to those at low-risk, due to higher rates of all-cause death and MI. Major bleeding rates were increased in high-risk patients (HR 1.59, 95% CI 1.25-2.02), but similar between the moderate and low-risk group. The Harrell's C-index for MACE was 0.60. CONCLUSION: The thrombotic risk criteria of the 2023 ESC guidelines for ACS enable to stratify patients undergoing PCI in categories with an incremental 1 year risk of MACE; however, their overall predictive ability for MACE is modest. Future studies should confirm the value of these criteria to identify patients benefiting from an extended treatment with a second antithrombotic agent.


Assuntos
Síndrome Coronariana Aguda , Cardiologia , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Inibidores da Agregação Plaquetária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio/etiologia , Trombose/diagnóstico , Trombose/epidemiologia , Trombose/etiologia , Hemorragia/induzido quimicamente , Sistema de Registros
9.
Can J Cardiol ; 40(2): 250-262, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38042339

RESUMO

Mitral regurgitation is a prevalent valvular disease, and its management has gained increasing importance because of the aging population. Although traditional surgery remains the gold standard, the field of transcatheter therapies, including transcatheter edge-to-edge repair and, more recently transcatheter mitral valve replacement are advancing and are being explored as viable alternatives, particularly for patients at high surgical risk. It is essential to emphasize the necessity of a multidisciplinary team approach, involving specialized valve teams, imaging experts, cardiac anaesthesiologists, and other relevant specialists, is crucial in achieving optimal outcomes. Furthermore, proper execution of procedures, postprocedural care, and diligent follow-up for these patients are essential components for successful results. It is essential to underscore that traditional mitral valve surgery continues to play a significant role. Simultaneously, it is important to acknowledge the expanding array of transcatheter interventions available for this specific patient population.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento
11.
Am J Cardiol ; 208: 6-12, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37806187

RESUMO

Prognostic implications of pulmonary hypertension (PH) in low-flow low-gradient (LG) aortic stenosis (AS) after transcatheter aortic valve replacement (TAVR) remains unexplored. We aimed to investigate the impact of baseline and changes in PH after TAVR. In this single-center retrospective study, we included patients who underwent TAVR for low-flow LG AS. Patients were categorized into 2 groups: baseline pulmonary artery systolic pressure (PASP) <46 mm Hg (no-to-mild PH) and PASP ≥46 mm Hg (moderate-to-severe PH). On the basis of changes in PASP after TAVR, patients were stratified into increased (ΔPASP ≥ + 5 mm Hg), no change (-4 to +4 mm Hg), and decreased (≤ -5 mm Hg) groups. Primary end point was a composite of all-cause mortality and heart failure rehospitalization. In total, 210 patients were included, 148 in the no-to-mild PH group and 62 in the moderate-to-severe PH group. Median follow-up was 13.2 months. The moderate-to-severe PH group was at an increased risk of composite end point (adjusted hazard ratio [HR] 3.5, 95% confidence interval [CI] 1.8 to 6.9), all-cause mortality (HR 2.4, 95% CI 1.1 to 5.6), and heart failure rehospitalization (HR 8.3, 95% CI 2.9 to 23.7). There were no differences in clinical outcomes among those with increased (32%), no change (28%), and decreased (39%) PASP after TAVR. In conclusion, moderate-to-severe PH at baseline is an independent predictor of worse clinical outcomes in patients with low-flow LG AS who undergo TAVR, and this cohort of patients do not seem to derive the benefits of postoperative reduction of PASP.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hipertensão Pulmonar/epidemiologia , Hipertensão Pulmonar/etiologia , Prognóstico , Estudos Retrospectivos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Índice de Gravidade de Doença
14.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438029

RESUMO

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Catéteres
15.
Am J Cardiol ; 201: 252-259, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37393727

RESUMO

Rotational atherectomy (RA) is widely used in the percutaneous treatment of heavily calcified coronary artery lesions in patients with chronic coronary syndromes (CCS). However, the safety and efficacy of RA in acute coronary syndrome (ACS) is not well established and is considered a relative contraindication. Therefore, we sought to evaluate the efficacy and safety of RA in patients presenting with non-ST-elevation myocardial infarction (NSTEMI), unstable angina (UA), and CCS. Consecutive patients who underwent percutaneous coronary intervention with RA between 2012 and 2019 at a tertiary single center were included. Patients presenting with ST-elevation myocardial infarction (MI) were excluded. The primary end points of interest were procedural success and procedural complications. The secondary end point was the risk of death or MI at 1 year. A total of 2,122 patients who underwent RA were included, of whom 1,271 presented with a CCS (59.9%), 632 presented with UA (29.8%), and 219 presented with NSTEMI (10.3%). Although an increased rate of slow-flow/no-reflow was noted in the UA population (p = 0.03), no significant difference in procedural success or procedural complications, including coronary dissection, perforation, or side-branch closure, was noted (p = NS). At 1 year, there were no significant differences in death or MI between CCS and non-ST-elevation ACS (NSTE-ACS: UA + NSTEMI; adjusted hazard ratio 1.39, 95% confidence interval 0.91 to 2.12); however, patients who presented with NSTEMI had a higher risk of death or MI than CCS (adjusted hazard ratio 1.79, 95% confidence interval 1.01 to 3.17). Use of RA in NSTE-ACS was associated with similar procedural success without an increased risk of procedural complications compared with patients with CCS. Although patients presenting with NSTEMI remained at higher risk of long-term adverse events, RA appears to be safe and feasible in patients with heavily calcified coronary lesions presenting with NSTE-ACS.


Assuntos
Síndrome Coronariana Aguda , Aterectomia Coronária , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Humanos , Aterectomia Coronária/efeitos adversos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/etiologia , Angina Instável/epidemiologia , Angina Instável/cirurgia , Angina Instável/tratamento farmacológico
17.
Front Cardiovasc Med ; 10: 1130354, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37351289

RESUMO

Aim: Transfemoral Trans-catheter Aortic Valve Replacement (TF-TAVR) is a safe and effective therapy compared with surgical aortic valve replacement (SAVR) in patients across all risk profiles using balloon-expandable valves (BEV) and self-expanding valves (SEV). Our aim was to compare safety and efficacy of BEV vs. SEV in high-risk patients undergoing TF-TAVR. Methods and results: We searched PubMed, EMBASE, Clinicaltrials.gov, Scopus, and Web of sciences for studies on patients with severe aortic stenosis undergoing TAVR. Primary outcome was 30-day all-cause mortality. Secondary outcomes defined by Valve Academic Research Consortium 2 (VARC-2) criteria were also examined. Six studies with 2,935 patients (1,439 to BEV and 1,496 to SEV) were included. BEV was associated with lower risk of all-cause mortality (2.2% vs. 4.5%; RR: 0.51; 95% CI: 0.31-0.82; p < 0.006) and cardiovascular mortality [(2.5% vs. 4.3%; RR: 0.54; 95% CI: 0.32-0.90; p = 0.01) at 30 days compared with SEV. Implantation of more than one valve per procedure (0.78% vs. 5.11%; RR: 0.15; 95% CI: 0.07-0.31; p < 0.00001), and moderate/severe AR/PVL (2.5% vs. 9.01%; RR: 0.3; 95% CI: 0.17-0.48); p < 0.00001) were also lower in the BEV arm. Conclusion: BEV TAVR is associated with reduced all-cause mortality (High level of GRADE evidence), cardiovascular mortality (very low level) at 30 days compared with SEV TAVR in high surgical risk patients. Data are necessary to determine if the difference in outcomes persists in longer-term and if the same effects are seen in lower-risk patients. Systematic Review Registration: identifier, CRD42020181190.

19.
Cardiovasc Revasc Med ; 49: 28-33, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36624012

RESUMO

INTRODUCTION: The Seattle Angina Questionnaire (SAQ-7) quantifies the impact of angina on patient functionality and quality of life. There is scarce data on the impact of social determinants and comorbidities on SAQ-7 in patients undergoing percutaneous coronary intervention (PCI) with planned staged PCI. METHODS: Patients completed a SAQ-7 before each PCI. Multivariable regression analysis was performed to study the impact of social determinants, comorbidities, and procedural characteristics on SAQ-7 scores at index PCI and at the time of the staged PCI. RESULTS: 531 patients were studied. Female sex, non-White race, coronary artery bypass graft history (CABG), and chronic lung disease were associated with lower baseline SAQ-7 scores. Overall, SAQ-7 increased between index procedure and staged PCI (11.9 ± 23.4). Body mass index (BMI) and the treatment of bifurcation lesions were independently associated with improvement of SAQ-7 between PCIs. Post-intervention, neither sex nor race was independently associated with changes in SAQ-7 scores. CONCLUSION: Different disparities and comorbid factors affect SAQ-7 before and after PCI. After revascularization, sex and race were not independent predictors of SAQ-7 improvement.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Qualidade de Vida , Angina Pectoris/terapia , Angina Pectoris/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Inquéritos e Questionários , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
20.
Heart Fail Rev ; 28(2): 465-483, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35900680

RESUMO

Conventional echocardiographic assessment may overestimate the left ventricular (LV) function in mitral regurgitation (MR). LV global longitudinal strain (GLS) is more sensitive marker to detect subclinical LV dysfunction. Multiple studies have investigated the prognostic value of LV-GLS in MR to examine its potential to determine the timing and indication of intervention. This systematic review aimed to assess the prognostic value of LV-GLS in patients with mitral regurgitation (MR) to define its clinical applicability. PUBMED and EMBASE were queried through July 2021 to identify studies investigating the prognostic value of LV-GLS in MR. A total of 24 observational studies with 5267 patients were identified. Sixteen studies investigated for primary MR, 7 studies for secondary MR, and 1 study for both. Most studies included patients who underwent intervention. There was significant heterogeneity in patient population, intervention status, follow-up period, LV-GLS cutoff value, outcomes, and statistical methods among the studies. Meta-analysis was not performed considering the significant variability. With exception to 1 study, all studies demonstrated significant association between impaired LV-GLS and worse clinical and echocardiographic outcomes in primary MR. Prognostic value of LV-GLS in secondary MR was less certain due to inconsistent findings and limited reporting. LV-GLS is a promising parameter of prognostication in primary MR and can be considered as alternative to determine the timing of intervention. However, the optimal cutoff value remains unclear. The prognostic value of LV-GLS in secondary MR is less clear. Further large-scale prospective study is warranted before its routine clinical application.


Assuntos
Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Prognóstico , Deformação Longitudinal Global , Estudos Prospectivos , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...