Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 26(9): 12159-12168, 2018 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-29716130

RESUMO

This article presents new spectroscopic results in standoff chemical detection that are enabled by monolithic arrays of Distributed Feedback (DFB) Quantum Cascade Lasers (QCLs), with each array element at a slightly different wavelength than its neighbor. The standoff analysis of analyte/substrate pairs requires a laser source with characteristics offered uniquely by a QCL Array. This is particularly true for time-evolving liquid chemical warfare agent (CWA) analysis. In addition to describing the QCL array source developed for long wave infrared coverage, a description of an integrated prototype standoff detection system is provided. Experimental standoff detection results using the man-portable system for droplet examination from 1.3 meters are presented using the CWAs VX and T-mustard as test cases. Finally, we consider three significant challenges to working with droplets and liquid films in standoff spectroscopy: substrate uptake of the analyte, time-dependent droplet spread of the analyte, and variable substrate contributions to retrieved signals.

2.
Sci Transl Med ; 9(408)2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-28931652

RESUMO

Assessing the adequacy of oxygen delivery to tissues is vital, particularly in the fields of intensive care medicine and surgery. As oxygen delivery to a cell becomes deficient, changes in mitochondrial redox state precede changes in cellular function. We describe a technique for the continuous monitoring of the mitochondrial redox state on the epicardial surface using resonance Raman spectroscopy. We quantify the reduced fraction of specific electron transport chain cytochromes, a metric we name the resonance Raman reduced mitochondrial ratio (3RMR). As oxygen deficiency worsens, heme moieties within the electron transport chain become progressively more reduced, leading to an increase in 3RMR. Myocardial 3RMR increased from baseline values of 18.1 ± 5.9 to 44.0 ± 16.9% (P = 0.0039) after inferior vena cava occlusion in rodents (n = 8). To demonstrate the diagnostic power of this measurement, 3RMR was continuously measured in rodents (n = 31) ventilated with 5 to 8% inspired oxygen for 30 min. A 3RMR value exceeding 40% at 10 min predicted subsequent cardiac arrest with 95% sensitivity and 100% specificity [area under the curve (AUC), 0.98], outperforming all current measures, including contractility (AUC, 0.51) and ejection fraction (AUC, 0.39). 3RMR correlated with indices of intracellular redox state and energy production. This technique may permit the real-time identification of critical defects in organ-specific oxygen delivery.


Assuntos
Parada Cardíaca/metabolismo , Mitocôndrias Cardíacas/metabolismo , Miocárdio/metabolismo , Miocárdio/patologia , Animais , Aorta/patologia , Hemodinâmica , Hemoglobinas/química , Hemoglobinas/metabolismo , Hipóxia/complicações , Hipóxia/patologia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/patologia , Mioglobina/química , Mioglobina/metabolismo , Oxirredução , Oxigênio/metabolismo , Ratos Sprague-Dawley , Análise Espectral Raman , Sus scrofa
3.
Opt Express ; 22(19): 22925-36, 2014 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-25321763

RESUMO

X-ray scattering has played a key role in non-destructive materials characterization due to the material-specific coherent scattering signatures. In the current energy dispersive coherent scatter imaging systems, including selected volume tomography and coherent scatter computed tomography, each object voxel is measured at a single scatter angle, which suffers from slow acquisition time. The employment of coded apertures in x-ray scatter imaging systems improves the photon collection efficiency, making it promising for real time volumetric imaging and material identification. In this paper, we propose a volumetric x-ray scatter imaging system using a pair of complementary coded apertures: a coded aperture on the detector side introduces multiplexed measurement on an energy-sensitive detector array; a complementary source-side coded aperture selectively illuminates the object to decouple the ambiguity due to the increased parallelization for 4D imaging. The system yields the 1D coherent scattering form factor at each voxel in 3D. We demonstrate tomographic imaging and material identification with the system and achieve a spatial resolution ~1 cm and a normalized momentum transfer resolution, Δq/q, of 0.2.


Assuntos
Imagens de Fantasmas , Fótons , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos , Raios X
4.
Analyst ; 139(4): 709-13, 2014 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-24340351

RESUMO

Tomographic imaging of the molecular structure of an object is important for a variety of applications, ranging from medical and industrial radiography to security screening. X-ray diffraction imaging is the preeminent technique for performing molecular analysis of large volumes. Here we propose and demonstrate a new measurement architecture to improve the source and detector efficiency for diffraction imaging. In comparison with previous techniques, our approach reduces the required overall scan time by 1-2 orders of magnitude, which makes possible real-time scanning of a broad range of materials over a large volume using a table-top setup. This method, which relies on structuring spatially the illumination incident on an object moving relative to the X-ray source, is compatible with existing systems and has the potential to significantly enhance performance in an array of areas, such as medical diagnostic imaging and explosives detection.

5.
Opt Lett ; 39(1): 111-4, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24365835

RESUMO

We present a method for realizing snapshot, depth-resolved material identification using only a single, energy-sensitive pixel. To achieve this result, we employ a coded aperture with subpixel features to modulate the energy spectrum of coherently scattered photons and recover the object properties using an iterative inversion algorithm based on compressed sensing theory. We demonstrate high-fidelity object estimation at x-ray wavelengths for a variety of compression ratios exceeding unity.

6.
Opt Express ; 21(21): 25480-91, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-24150387

RESUMO

We demonstrate a technique for measuring the range-resolved coherent scatter form factors of different objects from a single snapshot. By illuminating the object with an x-ray pencil beam and placing a coded aperture in front of a linear array of energy-sensitive detector elements, we record the coherently scattered x-rays. This approach yields lateral, range, and momentum transfer resolutions of 1 mm, 5 mm, and 0.2 nm⁻¹, respectively, which is sufficient for the distinguishing a variety of solids and liquids. These results indicate a path toward real-time volumetric molecular imaging for non-destructive examination in a variety of applications, including medical diagnostics, quality inspection, and security detection.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Iluminação/instrumentação , Imagem Molecular/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...