Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Comput Methods Programs Biomed ; 245: 108016, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237451

RESUMO

BACKGROUND AND OBJECTIVES: Age-related arterial stiffening increases peripheral resistance and decreases arterial distensibility, thus contributing to hypertension, an important risk factor of atherosclerosis. It causes abnormal blood flow, endothelial dysfunction, higher pulse wave velocity, and consequently elevated pressure wave amplitude. METHODS: This paper presents the influence of these changes via multiscale 3D-0D transient computational fluid dynamics simulations of blood flow in five patient-specific geometries of human carotid bifurcation using archetypal flow waveforms for young and old subjects. RESULTS: The proposed model shows a significant decrease in the time-averaged wall shear stress (TAWSS) for the old archetypal flow waveform. This is in good agreement with clinical data on a straight segment of common carotid arteries available for young and old subjects. Moreover, our study showed that the decrease of area-averaged TAWSS related to the old flow waveform is much more pronounced (2.5 ÷ 4.5 times higher) at risk areas (areas showing TAWSS below its threshold value of 0.48 Pa) than in straight segments commonly considered in clinical studies. CONCLUSIONS: Since arterial stiffness can be lowered through long-term usage of any of the five basic groups of antihypertensives, possible benefits of such medical therapy could be not only lowering blood pressure and peripheral resistance but also in increasing the TAWSS and thus attenuating an important mechanism of the atherosclerotic process.


Assuntos
Anti-Hipertensivos , Aterosclerose , Humanos , Anti-Hipertensivos/farmacologia , Análise de Onda de Pulso , Hemodinâmica/fisiologia , Artérias Carótidas , Simulação por Computador , Aterosclerose/tratamento farmacológico , Velocidade do Fluxo Sanguíneo , Modelos Cardiovasculares
3.
Front Neurol ; 14: 1132100, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37122308

RESUMO

Objectives: The study aims to analyze our first experience with direct percutaneous embolization of carotid body tumors (CBTs) using ethylene-vinyl alcohol copolymer (Onyx) along with balloon test occlusion (BTO). Methods: A retrospective preliminary single-center study was conducted at the Otorhinolaryngology and Head and Neck Surgery Department and the Medical Imaging Department of the University Teaching Hospital. A consecutive series of three patients with CBTs was treated at the local institution between October 2018 and June 2019. All three patients underwent preoperative percutaneous embolization using ethylene-vinyl alcohol copolymer (Onyx 18) with the addition of BTO. Outcome measures were the percentage of tumor devascularization, intraoperative blood losses, and operation times. BTO was evaluated by clinical neurological examination and neurosonological transcranial Doppler examination of the middle cerebral artery (MCA). Results: Devascularization of all three tumors was complete or near complete. All three tumors were surgically extirpated with excellent surgical outcomes. The blood losses were minimal, and the average operation time was 2 h and 8 min. BTO was positive in one patient, which was valuable additional information on carotid branches ligation limitations. The other two patients showed negative BTOs with the result of safety of eventual carotid arteries ligations. Conclusion: Preoperative direct percutaneous embolization of CBT with Onyx is a highly effective procedure that significantly facilitates surgery. BTO provides valuable additional information on the most appropriate and safe surgical approach.

4.
Vascular ; 31(6): 1061-1068, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35594244

RESUMO

OBJECTIVE: The purpose of our study was to describe perioperative kinetics of procalcitonin (PCT) in patients undergoing aortic surgery, to compare the kinetics in the open abdominal aortic aneurysm (AAA) repair and aortobifemoral bypass for aortoiliac occlusive disease (AIOD), and to evaluate the ability of PCT to detect intestinal ischaemia. METHODS: A prospective non-randomized observational cohort study in 80 patients (62 men and 18 women) undergoing elective aortic surgery was performed. Serum PCT was measured at baseline and defined intraoperative and postoperative timepoints up to postoperative day 7. MRI contrast-enhanced imaging was used to detect intestinal ischaemia. RESULTS: The comparison of the AAA and AIOD cohort did not show any significant difference in PCT levels. Patients with intestinal ischaemia had higher serum PCT at multiple timepoints postoperatively. The most accurate timepoints for early diagnosis were postoperative day 3, followed by 24 h after declamping of the vascular reconstruction, and postoperative day 7. The sensitivity and negative predictive values were 100% in all mentioned timepoints. However, event at the best timepoint the specificity was 89% and the positive predictive value 43%. CONCLUSIONS: Procalcitonin levels in the postoperative period at proper timepoints might help to detect postoperative intestinal ischaemia. The limitation of this marker is its low specificity for intestinal ischaemia and low positive predictive value. The highest value of this marker is that it can rule out this complication because normal PCT levels mean that intestinal ischaemia is very unlikely.


Assuntos
Aterosclerose , Síndrome de Leriche , Isquemia Mesentérica , Masculino , Humanos , Feminino , Pró-Calcitonina , Estudos Prospectivos , Abdome , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/cirurgia , Período Pós-Operatório , Isquemia/diagnóstico por imagem , Isquemia/cirurgia
5.
Clin Biochem ; 112: 43-47, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36502884

RESUMO

OBJECTIVES: Acute intestinal ischemia is a severe complication of abdominal aortic surgery that is difficult to diagnose early and therefore to treat adequately and timely. In this study the perioperative kinetics of d-lactate and ischemia-modified albumin (IMA) are described and the predictive value of these markers for the early diagnosis of acute intestinal ischemia is assessed. DESIGN & METHODS: This non-randomised, single-centre cohort study enrolled 50 patients with abdominal aortic aneurysm (AAA) and 30 patients with aortoiliac occlusive disease (AOID). Serum d-lactate and IMA were assessed pre-, intra-, and postoperatively at eight defined time points. RESULTS: The highest serum d-lactate was at 6 h after complete declamping of the vascular graft. The highest predictive power of d-lactate was at 3 h after complete declamping (AUC 0.857). IMA was found to be higher in the AAA group in ischemic patients 10 min after complete declamping than in the AOID group. The highest predictive values of IMA were at 1 h after aortic cross-clamping (AUC 0.758) and 3 and 6 h after complete declamping (0.745 and 0.721, respectively). Moreover, the multivariate model with both markers at 3 h after complete declamping improved the detection of intestinal ischemia (AUC 0.894). CONCLUSIONS: Serum levels of IMA and d-lactate seem to be influential predictive markers for postoperative intestinal ischemia, especially after 3 h from complete declamping of vascular reconstruction.


Assuntos
Aneurisma da Aorta Abdominal , Ácido Láctico , Humanos , Biomarcadores , Estudos de Coortes , Albumina Sérica , Isquemia/diagnóstico , Isquemia/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações
6.
Int J Surg ; 98: 106220, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34999001

RESUMO

BACKGROUND: Postoperative intestinal ischemia is a severe complication in abdominal aortic surgery. Early diagnosis is needed for adequate and timely treatment. We studied the postoperative kinetics of l-lactate in vascular patients to assess its value as a marker for early postoperative intestinal ischemia detection. MATERIAL AND METHODS: We performed a prospective non-randomized single-center observational cohort study in eighty elective patients, fifty operated on for abdominal aortic aneurysm (AAA) and thirty for aortoiliac occlusive disease (AIOD). Serum l-lactate was measured preoperatively, intraoperatively, and postoperatively at defined timepoints up to postoperative day 7. Intestinal ischemia was detected using MRI enterocolography. We have used univariate logistic regression and receiver operating characteristics curves for the evaluation of marker accuracy. RESULTS: We recorded 6 cases of postoperative intestinal ischemia (7.5%), five non-transmural and one transmural. Two patients died because of this complication (mortality 33%). The comparison of AAA and AIOD cohorts showed a significant difference in l-lactate levels at one intraoperative timepoint, which was attributable to procedure differences. The only preoperative factor associated with higher l-lactate levels at some timepoints was chronic kidney disease. Patients suffering postoperative intestinal ischemia had elevated serum l-lactate levels at multiple timepoints. The most accurate timepoint for diagnosis was 24 h after the declamping of the vascular reconstruction (DC24H), the second was 10 min after declamping. Sensitivity, specificity, positive and negative predictive values at timepoint DC24H were 100%, 82%, 32%, and 100%, respectively. CONCLUSION: Serum l-lactate levels might help in the early detection of postoperative intestinal ischemia after aortic surgery if proper timepoints are used. Cutoff values need to be established in large-scale prospective studies.


Assuntos
Aneurisma da Aorta Abdominal , Complicações Pós-Operatórias , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Isquemia/etiologia , Isquemia/cirurgia , Cinética , Lactatos , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos
7.
J Stroke Cerebrovasc Dis ; 29(9): 104978, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32807415

RESUMO

PURPOSE: The aim of the study was to compare the assessment of ischemic changes by expert reading and available automated software for non-contrast CT (NCCT) and CT perfusion on baseline multimodal imaging and demonstrate the accuracy for the final infarct prediction. METHODS: Early ischemic changes were measured by ASPECTS on the baseline neuroimaging of consecutive patients with anterior circulation ischemic stroke. The presence of early ischemic changes was assessed a) on NCCT by two experienced raters, b) on NCCT by e-ASPECTS, and c) visually on derived CT perfusion maps (CBF<30%, Tmax>10s). Accuracy was calculated by comparing presence of final ischemic changes on 24-hour follow-up for each ASPECTS region and expressed as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The subanalysis for patients with successful recanalization was conducted. RESULTS: Of 263 patients, 81 fulfilled inclusion criteria. Median baseline ASPECTS was 9 for all tested modalities. Accuracy was 0.76 for e-ASPECTS, 0.79 for consensus, 0.82 for CBF<30%, 0.80 for Tmax>10s. e-ASPECTS, consensus, CBF<30%, and Tmax>10s had sensitivity 0.41, 0.46, 0.49, 0.57, respectively; specificity 0.91, 0.93, 0.95, 0.91, respectively; PPV 0.66, 0.75, 0.82, 0.73, respectively; NPV 0.78, 0.80, 0.82, 0.83, respectively. Results did not differ in patients with and without successful recanalization. CONCLUSION: This study demonstrated high accuracy for the assessment of ischemic changes by different CT modalities with the best accuracy for CBF<30% and Tmax>10s. The use of automated software has a potential to improve the detection of ischemic changes.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Circulação Cerebrovascular , Imagem de Perfusão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/fisiopatologia , Isquemia Encefálica/terapia , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/terapia , Fatores de Tempo
8.
Comput Biol Med ; 83: 151-156, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28282590

RESUMO

PURPOSE: There is no standard for measuring maximal diameter (Dmax) of abdominal aortic aneurysm (AAA) from computer tomography (CT) images although differences between Dmax evaluated from transversal (axialDmax) or orthogonal (orthoDmax) planes can be large especially for angulated AAAs. Therefore we investigated their correlations with alternative rupture risk indicators as peak wall stress (PWS) and peak wall rupture risk (PWRR) to decide which Dmax is more relevant in AAA rupture risk assessment. MATERIAL AND METHODS: The Dmax values were measured by a trained radiologist from 70 collected CT scans, and the corresponding PWS and PWRR were evaluated using Finite Element Analysis (FEA). The cohort was ordered according to the difference between axialDmax and orthoDmax (Da-o) quantifying the aneurysm angulation, and Spearman's correlation coefficients between PWS/PWRR - orthoDmax/axialDmax were calculated. RESULTS: The calculated correlations PWS/PWRR vs. orthoDmax were substantially higher for angulated AAAs (with Da-o≥3mm). Under this limit, the correlations were almost the same for both Dmax values. Analysis of AAAs divided into two groups of angulated (n=38) and straight (n=32) cases revealed that both groups are similar in all parameters (orthoDmax, PWS, PWRR) with the exception of axialDmax (p=0.024). CONCLUSIONS: It was confirmed that orthoDmax is better correlated with the alternative rupture risk predictors PWS and PWRR for angulated AAAs (DA-O≥3mm) while there is no difference between orthoDmax and axialDmax for straight AAAs (DA-O<3mm). As angulated AAAs represent a significant portion of cases it can be recommended to use orthoDmax as the only Dmax parameter for AAA rupture risk assessment.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/epidemiologia , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Aneurisma Roto/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Simulação por Computador , República Tcheca/epidemiologia , Humanos , Modelos Cardiovasculares , Prevalência , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...