1.
Rev Sci Instrum ; 89(10): 10D107, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399868

RESUMO

Diagnosing the density profile at the edge of high temperature fusion plasmas by an accelerated lithium beam is a known technique since decades. By knowledge of the relevant atomic physics rate coefficients, the plasma electron density profile can be calculated from the relatively calibrated light profile along the beam. Several additional possibilities have already been demonstrated: Charge Exchange Resonance Spectroscopy (CXRS) for ion temperature/flow and Zeeman polarimetry for edge plasma current; therefore the Li-beam diagnostic offers a wealth of information at the plasma edge. The weaknesses of the method are the relatively faint light signal, background light, and technical difficulties of the beam injector which usually seriously limit the applicability. In this talk, we present systematic developments in alkali-beam diagnostics (Li, Na) for the injector and the observation system and detectors which resulted in strongly increased capabilities. Advanced systems have been built, and microsecond scale density profile, turbulence, and zonal flow measurement have been demonstrated. A novel edge current measurement technique has also been designed, and components have been tested with potential microsecond-scale time resolution. Additional possibilities of these advanced systems for spectral measurements (CXRS and various Zeeman schemes) are also discussed.

2.
Rev Sci Instrum ; 89(6): 063503, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29960560

RESUMO

A diagnostic instrument is described for the Experimental Advanced Superconducting Tokamak (EAST) for the measurement of the edge plasma electron density profile and plasma turbulence properties. An accelerated neutral lithium beam is injected into the tokamak and the Doppler shifted 670.8 nm light emission of the Li2p-2s transition is detected. A novel compact setup is used, where the beam injection and observation take place from the same equatorial diagnostic port and radial-poloidal resolution is achieved with microsecond time resolution. The observation direction is optimized in order to achieve a sufficient Doppler shift of the beam light to be able to separate from the strong edge lithium line emission on this lithium coated device. A 250 kHz beam chopping technique is also demonstrated for the removal of background light. First results show the capability of measuring turbulence and its poloidal flow velocity in the scrape-off layer and edge region and the resolution of details of transient phenomena like edge localized modes with few microsecond time resolution.

3.
Rev Sci Instrum ; 89(1): 013503, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29390651

RESUMO

A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

4.
Rev Sci Instrum ; 83(1): 013508, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22299952

RESUMO

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D(α) emission from the ~2 MW heating beam of ~70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 × 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of ~2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of ~10(11) s(-1) the achieved signal-to-noise ratio of ~300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.