Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiol Oncol ; 54(2): 247-252, 2020 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-32374291

RESUMO

Background High energy electron linear accelerators (LINACs) producing photon beams with energies higher than 10 MeV are widely used in radiation therapy. In these beams, fast neutrons are generated, which results in undesired contamination of the therapeutic beam. In this study, measurements and Monte Carlo (MC) simulations were used to obtain neutron spectra and dose equivalents in vicinity of linear accelerator. Materials and methods LINAC Siemens Oncor Expression in Osijek University Hospital is placed in vault that was previously used for 60Co machine. Then, the shielding of the vault was enhanced using lead and steel plates. Measurements of neutron dose equivalent around LINAC and the vault were done using CR-39 solid state nuclear track detectors. To compensate energy dependence of detectors, neutron energy spectra was calculated in measuring positions using MC simulations. Results The vault is a source of photoneutrons, but a vast majority of neutrons originates from accelerator head. Neutron spectra obtained from MC simulations show significant changes between the measuring positions. Annual neutron dose equivalent per year was estimated to be less than 324 µSv in the measuring points outside of the vault. Conclusions Since detectors used in this paper are very dependent on neutron energy, it is extremely important to know the neutron spectra in measuring points. Though, patient dosimetry should include neutrons, estimated annual neutron doses outside the vault were far below exposure limit of ionizing radiation for workers.


Assuntos
Nêutrons Rápidos , Aceleradores de Partículas , Proteção Radiológica/métodos , Método de Monte Carlo , Nêutrons , Doses de Radiação , Monitoramento de Radiação/métodos , Radiometria/métodos , Fatores de Tempo
2.
Radiat Prot Dosimetry ; 162(1-2): 29-33, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24993009

RESUMO

Long-term indoor radon measurements performed by LR 115 track etched detectors in Croatian homes during 2003-04 showed that the arithmetic means of radon concentrations in Lika-Senj and the southern part of Karlovac counties were three times higher (198 Bq m(-3)) than in houses at national level (68 Bq m(-3)). Recently, indoor radon measurements in randomly selected houses were investigated. The obtained values in these new measurements have confirmed the values obtained 10 y ago (the average radon value in 225 investigated houses in this area is 223 Bq m(-3)). Radon concentrations in soil gas were measured in September and October 2012 and 2013 with the AlphaGUARD measuring system. Areas with both elevated indoor radon levels and radon in soil gas were identified (some micro locations in Korenica, Licko Lesce, Generalski Stol, Slunj and Ogulin) and visually presented in the form of maps using the inverse distance weighting approach.


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Habitação , Monitoramento de Radiação , Radônio/análise , Poluentes do Solo/análise , Croácia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA