Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
PLoS One ; 10(2): e0117358, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25710485

RESUMO

BACKGROUND: HIFU has been shown to be a more suitable alternative for the treatment of primary solid tumors and metastatic diseases than other focal heat ablation techniques due to its noninvasive and extracorporeal nature. However, similar to other focal heat ablation techniques, HIFU is still in need of refinements due to tumor recurrence. METHODS: In this work, we investigated the effectiveness of an adjunct treatment regimen using doxorubicin (DOX)-loaded, injectable, in situ-forming, and phase-inverting PLGA as the second line of defense after HIFU ablation to destroy detrimental residual tumors and to prevent tumor recurrence. All of the statistical analyses were performed using the Statistical Package for the Social Sciences 18.0 (SPSS, Inc., Chicago, IL, USA), and p<0.05 was considered statistically significant. All of the results are presented as the means ± STDEV (standard deviation). For multiple comparisons, ANOVA (differences in tumor volumes, growth rates, apoptosis, proliferation indexes, and Bcl-2 and Bax protein levels) was used when the data were normally distributed with homogenous variance, and rank sum tests were used otherwise. Once significant differences were detected, Student-t tests were used for comparisons between two groups. RESULTS: Our results revealed that DOX diffused beyond the ablated tissue regions and entered tumor cells that were not affected by the HIFU ablation. Our results also show that HIFU in concert with DOX-loaded PLGA led to a significantly higher rate of tumor cell apoptosis and a lower rate of tumor cell proliferation in the areas beyond the HIFU-ablated tissues and consequently caused significant tumor volume shrinkage (tumor volumes:0.26±0.1,1.09±0.76, and 1.42±0.9 cm3 for treatment, sham, and no treatment control, respectively). CONCLUSIONS: From these results, we concluded that the intralesional injection of DOX-loaded PLGA after HIFU ablation is significantly more effective than HIFU alone for the treatment of solid tumors.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Ablação por Ultrassom Focalizado de Alta Intensidade , Ácido Láctico/química , Neoplasia Residual/tratamento farmacológico , Ácido Poliglicólico/química , Animais , Antibióticos Antineoplásicos/química , Apoptose , Doxorrubicina/química , Portadores de Fármacos/química , Microbolhas , Neoplasia Residual/diagnóstico por imagem , Neoplasia Residual/patologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Antígeno Nuclear de Célula em Proliferação/metabolismo , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Coelhos , Neoplasias Cutâneas/patologia , Resultado do Tratamento , Ultrassonografia , Proteína X Associada a bcl-2/metabolismo
3.
Ultrasound Med Biol ; 39(11): 2137-46, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23932272

RESUMO

In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rates in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within the tumor parenchyma.


Assuntos
Fluorocarbonos/farmacocinética , Nanopartículas , Poloxâmero/farmacocinética , Ultrassonografia/métodos , Animais , Fluorocarbonos/química , Teste de Materiais , Taxa de Depuração Metabólica , Camundongos , Camundongos Nus , Nanopartículas/química , Especificidade de Órgãos , Imagens de Fantasmas , Poloxâmero/química , Distribuição Tecidual , Ultrassonografia/instrumentação
4.
Biomaterials ; 34(9): 2307-17, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23276658

RESUMO

Current strategies for tumor-induced sentinel lymph node detection and metastasis therapy have limitations. In this work, we co-encapsulated iron oxide nanoparticles and chemotherapeutic drug into poly(lactic-co-glycolic acid) (PLGA) microbubbles to form multifunctional polymer microbubbles (MPMBs) for both tumor lymph node imaging and therapy. Fe(3)O(4) nanoparticles and doxorubicin (DOX) co-encapsulated PLGA microbubbles were prepared and filled with perfluorocarbon gas. Enhancement of ultrasound (US)/magnetic resonance (MR) imaging and US triggered drug delivery were evaluated both in vitro and in vivo. The MPMBs exhibited characters like narrow size distribution and smooth surface with a mean diameter of 868.0 ± 68.73 nm. In addition, varying the concentration of Fe(3)O(4) nanoparticles in the bubbles did not significantly influence the DOX encapsulation efficiency or drug loading efficiency. Our in vitro results demonstrated that these MPMBs could enhance both US and MR imaging which was further validated in vivo showing that these MPMBs enhanced tumor lymph nodes signals. The anti-tumor effect of MPMBs mediated chemotherapy was assessed in vivo using end markers like tumor proliferation index, micro blood vessel density and micro lymphatic vessel density, which were shown consistently the lowest after the MPMBs plus sonication treatment compared to controls. In line with these findings, the tumor cell apoptotic index was found the largest after the MPMBs plus sonication treatment. In conclusion, we have successfully developed a doxorubicin loaded superparamagnetic PLGA-Iron Oxide multifunctional theranostic agent for dual-mode US/MR Imaging of lymph node, and for low frequency US triggered therapy of metastasis in lymph nodes, which might provide a strategy for the imaging and chemotherapy of primary tumor and their metastases.


Assuntos
Doxorrubicina/farmacologia , Ácido Láctico/farmacologia , Linfonodos/efeitos dos fármacos , Imageamento por Ressonância Magnética/métodos , Microbolhas , Ácido Poliglicólico/farmacologia , Animais , Linhagem Celular Tumoral , Meios de Contraste , Sistemas de Liberação de Medicamentos , Linfonodos/patologia , Metástase Linfática , Nanopartículas/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Ultrassom
5.
Eur J Radiol ; 82(3): 512-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23079049

RESUMO

OBJECTIVES: The nerve ending problem is one of the major causes for diabetic feet. In this work, we explored the feasibilities of using high frequency ultrasound (US) in nerve ending problem evaluation for patients with diabetic foot. METHODS: The endings of the medial branch of deep peroneal nerves (mbDPN) were interrogated by US, and the nerve conduction characters were studied in a cohort of 19 clinically diagnosed diabetic feet patients and a control group of healthy volunteers. RESULTS: Distinct echoic appearances were consistently detected between the mbDPN nerves of diabetic feet patients and healthy volunteers. In healthy volunteers, hypoechoic bands were readily observed at the anatomical locations of mbDPNs. However, these hypoechoic bands of the mbDPNs were not clear in the diabetic feet patients, and the surfaces of the mbDPNs appeared obscure and irregular in these patients relative to those of healthy volunteers. In addition, the US echoes of mbDPN in patients with diabetic feet were more heterogeneous than those in healthy volunteers. The mean diameters of mbDPNs were 1.3±0.4 mm in patients with diabetic foot and 0.8±0.2 mm in the control group (P<0.05). Finally, results from the nerve conduction studies (NCS) showed abnormalities in patients with diabetic feet syndrome. CONCLUSION: High frequency US can be a useful modality for evaluating nerve ending problems in diabetic feet patient; and the mbDPN enlargement, obscurity, surface irregularity and heterogeneity in echo can serve as the markers indicating nerve ending problems in the diabetic feet patients under ultrasound interrogation.


Assuntos
Pé Diabético/complicações , Pé Diabético/diagnóstico por imagem , Terminações Nervosas/diagnóstico por imagem , Nervo Fibular/diagnóstico por imagem , Neuropatias Fibulares/complicações , Neuropatias Fibulares/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
6.
Clin Imaging ; 36(5): 577-83, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22920365

RESUMO

This article represents an initial attempt to demonstrate the feasibility of a novel method for measuring flow velocity in small vessels, which is a direct, noninvasive, ultrasound-guided, and Doppler angle-independent method. In vitro, experiments were designed to mimic blood flow inside tubes. Harmonic ultrasound imaging was used to track the movement of microbubbles, and the mean flow velocity was calculated. In vivo, the flow velocities were measured in the central arteries of rabbit ears. This method can be used whenever the Doppler ultrasound cannot measure the velocity in small vessels because of either low sensitivity or Doppler angle limitation.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste/química , Orelha/irrigação sanguínea , Ultrassonografia Doppler/métodos , Animais , Interpretação de Imagem Assistida por Computador , Microbolhas , Imagens de Fantasmas , Coelhos
7.
Biomaterials ; 33(24): 5854-64, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22617321

RESUMO

Organic/inorganic, hybrid, multifunctional, material-based platforms combine the merits of diverse functionalities of inorganic nanoparticles and the excellent biocompatibility of organic systems. In this work, superparamagnetic poly(lactic-co-glycolic acid) (PLGA) microcapsules (Fe(3)O(4)/PLGA) have been developed, as a proof-of-concept, for the application in ultrasound/magnetic resonance dual-modality biological imaging and enhancing the therapeutic efficiency of high intensity focused ultrasound (HIFU) breast cancer surgery in vitro and in vivo. Hydrophobic Fe(3)O(4) nanoparticles were successfully integrated into PLGA microcapsules by a typical double emulsion evaporation process. In this process, highly dispersed superparamagnetic Fe(3)O(4)/PLGA composite microcapsules with well-defined spherical morphology were obtained with an average diameter of 885.6 nm. The potential of these microcapsules as dual contrast agents for ultrasonography and magnetic resonance imaging were demonstrated in vitro and, also, preliminarily in vivo. Meanwhile, the prepared superparamagnetic composite microcapsules were administrated into rabbits bearing breast cancer model for the evaluation of the in vivo HIFU synergistic ablation efficiency caused by the introduction of such microcapsules. Our results showed that the employment of the composite microcapsules could efficiently enhance ultrasound imaging of cancer, and greatly enhance the HIFU ablation of breast cancer in rabbits. In addition, pathological examination was systematically performed to detect the structural changes of the target tissue caused by HIFU ablation. This finding demonstrated that successful introduction of these superparamagnetic microcapsules into HIFU cancer surgery provided an alternative strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy of cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Cápsulas , Compostos Férricos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ácido Láctico , Imageamento por Ressonância Magnética/métodos , Ácido Poliglicólico , Animais , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Cápsulas/química , Cápsulas/uso terapêutico , Meios de Contraste/química , Meios de Contraste/uso terapêutico , Feminino , Compostos Férricos/química , Compostos Férricos/uso terapêutico , Humanos , Ácido Láctico/química , Ácido Láctico/uso terapêutico , Ácido Poliglicólico/química , Ácido Poliglicólico/uso terapêutico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Ultrassonografia Mamária
8.
Clin Breast Cancer ; 12(3): 199-206, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22402214

RESUMO

Lymph node (LN) examination plays a critical role in the staging and treatment of several kinds of cancer such as lesions of the breast. However current strategies have limitations. This study aimed to develop a novel imaging agent, a polymeric ultrasonographic contrast agent carrying Sudan black (SB), for ultrasonographic imaging of the regional LNs before surgery and to directly localize the LNs during surgery. The poly(lactide-co-glycolide) (PLGA) ultrasonographic microbubbles carrying Sudan black B (SB) (SB-PLGA microbubbles) were prepared by the double emulsion method. The SB-PLGA microbubbles had a diameter of 1.5 ± 0.5 µm and the SB encapsulation efficiency was (86.2 ± 1.56%). Results from MTT assays suggested that these bubbles have little cytotoxicity to mouse macrophages after incubation. Confocal laser scanning microscopy showed that the PLGA microbubbles carrying the fluorescent dye rhodamine 6G were taken up by macrophages after 2-hour incubation. In addition, these SB-PLGA microbubbles were able to enhance ultrasonographic contrast of 12 popliteal LNs of 6 rabbits. Furthermore, the LNs were easily identifiable by the naked eye during surgery because of the blue color of the SB-PLGA microbubbles inside the LNs. By cryosectioning and hematoxylin and eosin (H&E) staining of LN tissue, our results showed that these SB-PLGA microbubbles were internalized inside the macrophages of the LNs. To conclude, the SB-PLGA microbubbles could be a suitable imaging agent for preoperative and intraoperative localization of LNs as well as for a preoperative ultrasonographically guided core needle biopsy of suspicious sentinel lymph nodes (SLNs) in cancer patients, hence enhancing treatment outcome.


Assuntos
Compostos Azo/administração & dosagem , Ácido Láctico/administração & dosagem , Linfonodos/patologia , Ácido Poliglicólico/administração & dosagem , Biópsia de Linfonodo Sentinela/métodos , Animais , Compostos Azo/efeitos adversos , Compostos Azo/química , Compostos Azo/farmacocinética , Células Cultivadas , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Meios de Contraste/química , Meios de Contraste/farmacocinética , Portadores de Fármacos , Período Intraoperatório , Ácido Láctico/efeitos adversos , Ácido Láctico/química , Ácido Láctico/farmacocinética , Linfonodos/efeitos dos fármacos , Linfonodos/metabolismo , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Camundongos , Microbolhas , Naftalenos , Ácido Poliglicólico/efeitos adversos , Ácido Poliglicólico/química , Ácido Poliglicólico/farmacocinética , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Período Pré-Operatório , Coelhos , Biópsia de Linfonodo Sentinela/instrumentação , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
9.
Ultrasound Med Biol ; 38(3): 443-53, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22266229

RESUMO

Benign periablational enhancement (BPE) response to thermal injury is a barrier to early detection of residual tumor in contrast enhanced imaging after radio-frequency (RF) ablation. The objective of this study was to evaluate the role of quantitative of contrast-enhanced ultrasound (CEUS) in early differentiation of BPE from residual tumor in a BD-IX rat subcutaneous colon cancer model. A phantom study was first performed to test the validity of the perfusion parameters in predicting blood flow of two US contrast imaging modes-contrast harmonic imaging (CHI) and microflow imaging (MFI). To create a simple model of BPE, a peripheral portion of the tumor was ablated along with surrounding normal tissue, leaving part of the tumor untreated. First-pass dynamic enhancement (FPDE) and MFI scans of CEUS were performed before ablation and immediately, 1, 4 and 7 days after ablation. Time-intensity-curves in regions of BPE and residual tumor were fitted to the function y = A(1-exp[-ß{t-t0}])+C, in which A, ß, t0 and C represent blood volume, flow speed, time to start and baseline intensity, respectively. In the phantom study, positive linear correlations were noted between A, ß, Aß and contrast concentration, speed and flow rate, respectively, in both CHI and MFI. On CEUS images of the in vivo study, the unenhanced ablated zone was surrounded by BPE and irregular peripheral enhancement consistent with residual tumor. On days 0, 4 and 7, blood volume (A) in BPE was significantly higher than that in residual tumor in both FPDE imaging and MFI. Significantly greater blood flow (Aß) was seen in BPE compared with residual tumor tissue in FPDE on day 7 and in MFI on day 4. The results of this study demonstrate that qualitative CEUS can be potentially used for early detection of viable tumor in post-ablation assessment.


Assuntos
Ablação por Cateter/métodos , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/cirurgia , Cirurgia Assistida por Computador/métodos , Ultrassonografia/métodos , Animais , Linhagem Celular Tumoral , Meios de Contraste , Diagnóstico Diferencial , Microbolhas , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Falha de Tratamento , Resultado do Tratamento
10.
Int J Hyperthermia ; 27(7): 663-71, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21992559

RESUMO

PURPOSE: To identify specific Pluronic triblock copolymer structural properties which are critical to its function as a sensitiser in hyperthermia treatment of experimental colorectal adenocarcinoma. MATERIALS AND METHODS: DHD/K12/TRb rat colorectal adenocarcinoma cells were exposed to Pluronics, a family of triblock copolymers with the general structure EO(x)-PO(y)-EO(x) (EO: ethylene oxide, and PO: propylene oxide), at a range of molecular weights (Mw) and EO:PO:EO sub-unit lengths and then submitted to sublethal heat (43°C) treatment. Outcomes indicating Pluronic performance as a thermal sensitiser were correlated with its structural properties; lead candidates were determined accordingly. Finally, one of the lead candidates, Pluronic L61, a 2000 Da copolymer, was used to assess sensitising functionality in vivo in a subcutaneous rat model of colorectal carcinoma. RESULTS: Pluronics with 1100 ≤ Mw ≤ 3200 Da and hydrophilic lipophilic balance (HLB) between 1-8 demonstrated the highest thermosensitising ability. Pluronics L31, L61, L62, L10 and L64 were found to be among the most effective copolymers for hyperthermia sensitisation under tested conditions. Most encouraging, L61 in synergy with hyperthermia significantly reduced tumour growth progression in vivo compared to tumours treated with hyperthermia alone. CONCLUSIONS: Pluronic copolymer structure properties including, Mw, HLB and PO length are essential to its hyperthermia sensitising function.


Assuntos
Adenocarcinoma/terapia , Neoplasias Colorretais/terapia , Hipertermia Induzida/métodos , Poloxâmero/química , Animais , Apoptose/efeitos dos fármacos , Ablação por Cateter , Linhagem Celular Tumoral , Interações Hidrofóbicas e Hidrofílicas , Masculino , Peso Molecular , Poloxâmero/uso terapêutico , Ratos
11.
Int J Hyperthermia ; 27(7): 672-81, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21992560

RESUMO

PURPOSE: The goal of this study was to evaluate the relationship between previously demonstrated thermosensitising effects of the block copolymer, Pluronic, and heat shock protein 70 (Hsp70) expression in an experimental colorectal cancer model in vitro and in vivo. MATERIALS AND METHODS: Rat colorectal carcinoma cells were treated with low-grade hyperthermia (43°C) alone or in combination with Pluronics L10 (3 mg/mL), L61 (0.3 mg/mL), or L64 (0.5 mg/mL) for 20 min. Adinosine triphosphate (ATP) levels and cell viability were determined using standard assays. Hsp70 expression was quantified by western blot for cells treated with L10, L61, and L64 at doses specified above and Pluronic P85 (10 mg/mL) alone and in combination with heat. BDIX rats with flank tumours were used to study the effect of L61 and hyperthermia on Hsp70 expression in vivo. RESULTS: In vitro, treatment with L10, L61, and L64 plus low-grade hyperthermia lead to depletion of ATP levels to between 8 and 66% of untreated control after 24 h. Maximum expression of Hsp70 was observed at 9 h following hyperthermia alone. The combination of low-grade hyperthermia and Pluronic treatment reduced Hsp70 expression for up to 6 hours, and L10 appeared to completely inhibit the Hsp70 expression. In vivo, Hsp70 expression was increased 5 h after hyperthermia in BDIX rat tumour models and no Hsp70 expression was observed in L61 pre-treated and control groups. CONCLUSION: Pluronic effectively improves hyperthermic and low-grade hyperthermic treatment in part due to reduction of Hsp70 expression.


Assuntos
Adenocarcinoma/metabolismo , Neoplasias Colorretais/metabolismo , Proteínas de Choque Térmico HSP70/biossíntese , Poloxâmero/farmacologia , Animais , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Proteínas de Choque Térmico HSP70/antagonistas & inibidores , Hipertermia Induzida , Ratos
12.
J Control Release ; 147(3): 350-8, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20728486

RESUMO

In situ forming drug delivery implants offer an attractive alternative to pre-formed implant devices for local drug delivery due to their ability to deliver fragile drugs, simple manufacturing process, and less invasive placement. However, the clinical translation of these systems has been hampered, in part, by poor correlation between in vitro and in vivo drug release profiles. To better understand this effect, the behavior of poly(D,l-lactide-co-glycolide) (PLGA) in situ forming implants was examined in vitro and in vivo after subcutaneous injection as well as injection into necrotic, non-necrotic, and ablated tumor. Implant formation was quantified noninvasively using an ultrasound imaging technique. Drug release of a model drug agent, fluorescein, was correlated with phase inversion in different environments. Results demonstrated that burst drug release in vivo was greater than in vitro for all implant formulations. Drug release from implants in varying in vivo environments was fastest in ablated tumor followed by implants in non-necrotic tumor, in subcutaneous tissue, and finally in necrotic tumor tissue with 50% of the loading drug mass released in 0.7, 0.9, 9.7, and 12.7h respectively. Implants in stiffer ablated and non-necrotic tumor tissue showed much faster drug release than implants in more compliant subcutaneous and necrotic tumor environments. Finally, implant formation examined using ultrasound confirmed that in vivo the process of precipitation (phase inversion) was directly proportional to drug release. These findings suggest that not only is drug release dependent on implant formation but that external environmental effects, such as tissue mechanical properties, may explain the differences seen between in vivo and in vitro drug release from in situ forming implants.


Assuntos
Antineoplásicos/administração & dosagem , Ablação por Cateter , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/cirurgia , Fluoresceína/administração & dosagem , Corantes Fluorescentes/administração & dosagem , Ácido Láctico/química , Ácido Poliglicólico/química , Animais , Antineoplásicos/química , Antineoplásicos/farmacocinética , Linhagem Celular Tumoral , Quimioterapia Adjuvante , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Implantes de Medicamento , Fluoresceína/química , Fluoresceína/farmacocinética , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Injeções Subcutâneas , Masculino , Microscopia Eletrônica de Varredura , Peso Molecular , Necrose , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Porosidade , Pressão , Ratos , Solubilidade , Estresse Mecânico , Propriedades de Superfície , Ultrassonografia
13.
Mol Pharm ; 7(1): 49-59, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19957968

RESUMO

The advent of microbubble contrast agents has enhanced the capabilities of ultrasound as a medical imaging modality and stimulated innovative strategies for ultrasound-mediated drug and gene delivery. While the utilization of microbubbles as carrier vehicles has shown encouraging results in cancer therapy, their applicability has been limited by a large size which typically confines them to the vasculature. To enhance their multifunctional contrast and delivery capacity, it is critical to reduce bubble size to the nanometer range without reducing echogenicity. In this work, we present a novel strategy for formulation of nanosized, echogenic lipid bubbles by incorporating the surfactant Pluronic, a triblock copolymer of ethylene oxide copropylene oxide coethylene oxide into the formulation. Five Pluronics (L31, L61, L81, L64 and P85) with a range of molecular weights (M(w): 1100 to 4600 Da) were incorporated into the lipid shell either before or after lipid film hydration and before addition of perfluorocarbon gas. Results demonstrate that Pluronic-lipid interactions lead to a significantly reduced bubble size. Among the tested formulations, bubbles made with Pluronic L61 were the smallest with a mean hydrodynamic diameter of 207.9 +/- 74.7 nm compared to the 880.9 +/- 127.6 nm control bubbles. Pluronic L81 also significantly reduced bubble size to 406.8 +/- 21.0 nm. We conclude that Pluronic is effective in lipid bubble size control, and Pluronic M(w), hydrophilic-lipophilic balance (HLB), and Pluronic/lipid ratio are critical determinants of the bubble size. Most importantly, our results have shown that although the bubbles are nanosized, their stability and in vitro and in vivo echogenicity are not compromised. The resulting nanobubbles may be better suited for contrast enhanced tumor imaging and subsequent therapeutic delivery.


Assuntos
Meios de Contraste , Lipídeos , Microbolhas , Poloxâmero , Ultrassonografia/métodos , Animais , Neoplasias Colorretais/diagnóstico por imagem , Meios de Contraste/química , Portadores de Fármacos , Estabilidade de Medicamentos , Feminino , Interações Hidrofóbicas e Hidrofílicas , Lipídeos/química , Tamanho da Partícula , Poloxâmero/química , Ratos , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Ther Deliv ; 1(2): 307-22, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22816134

RESUMO

Image-guided drug delivery provides a means for treating a variety of diseases with minimal systemic involvement while concurrently monitoring treatment efficacy. These therapies are particularly useful to the field of interventional oncology, where elevation of tumor drug levels, reduction of systemic side effects and post-therapy assessment are essential. This review highlights three such image-guided procedures: transarterial chemoembolization, drug-eluting implants and convection-enhanced delivery. Advancements in medical imaging technology have resulted in a growing number of new applications, including image-guided drug delivery. This minimally invasive approach provides a comprehensive answer to many challenges with local drug delivery. Future evolution of imaging devices, image-acquisition techniques and multifunctional delivery agents will lead to a paradigm shift in patient care.


Assuntos
Antineoplásicos/administração & dosagem , Quimioembolização Terapêutica , Diagnóstico por Imagem , Sistemas de Liberação de Medicamentos , Implantes de Medicamento , Neoplasias/tratamento farmacológico , Animais , Antineoplásicos/farmacocinética , Disponibilidade Biológica , Transporte Biológico , Química Farmacêutica , Convecção , Portadores de Fármacos , Composição de Medicamentos , Humanos , Neoplasias/metabolismo , Neoplasias/patologia , Tecnologia Farmacêutica/métodos
15.
Acad Radiol ; 16(3): 321-31, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19201361

RESUMO

RATIONALE AND OBJECTIVES: Inflammatory reaction surrounding the ablated area is a major confounding factor in the early detection of viable tumor after radiofrequency (RF) ablation. A difference in the responsiveness of normal and tumor blood vessels to vasoactive agents may be used to distinguish these regions in post-ablation follow-up. The goal of this study was to examine longitudinal perfusion changes in untreated viable tumor and the peripheral hyperemic rim of RF-ablated tumor in response to a vasoconstrictor (phenylephrine) or vasodilator (hydralazine) in a subcutaneous rat tumor model. MATERIALS AND METHODS: Bilateral subcutaneous shoulder tumors were inoculated in 24 BDIX rats and evenly divided into two groups (phenylephrine and hydralazine groups). One tumor in each animal was completely treated with RF ablation (at 90 +/- 2 degrees C for 3 minutes), and the other remained untreated. Computed tomographic perfusion scans before and after phenylephrine (10 microg/kg) or hydralazine (5 mg/kg) administration were performed 2, 7, and 14 days after ablation. Four rats per group were euthanized on each scan day, and pathologic evaluation was performed. The changes of blood flow in the peripheral rim of ablated tumor and untreated viable tumor in response to phenylephrine or hydralazine at each time point were compared. The diagnostic accuracy of viable tumor using the percentage change of blood flow in response to phenylephrine and hydralazine was compared using receiver-operating characteristic analysis. RESULTS: The peripheral rim of ablated tumor presented with a hyperemic reaction with dilated vessels and congestion on day 2 after ablation, numerous inflammatory vessels on day 7, and granulation tissue formation on day 14. Phenylephrine significantly decreased the blood flow in the peripheral hyperemic rim of ablated tumor on days 2, 7, and 14 by 16.3 +/- 9.7% (P = .001), 24.0 +/- 22.6% (P = .007), and 31.1 +/- 25.4% (P = .045), respectively. In untreated viable tumor, the change in blood flow after phenylephrine was irregular and insignificant. Hydralazine decreased the blood flow in the peripheral rim of both ablated tumor and untreated viable tumor. Receiver-operating characteristic analysis showed that reliable tumor diagnosis using the percentage change of blood flow in response to phenylephrine was noted on days 2 and 7, for which the areas under the curve were 0.82 (95% confidence interval, 0.64-1.00) and 0.81 (95% confidence interval, 0.56-1.00), respectively. However, tumor diagnosis using the blood flow change in response to hydralazine was unreliable. CONCLUSION: Phenylephrine markedly decreased blood flow in the peripheral hyperemic rim of ablated tumor but had little effect on the untreated viable tumor. Computed tomographic perfusion with phenylephrine may be useful in the long-term treatment assessment of RF ablation.


Assuntos
Modelos Animais de Doenças , Aumento da Imagem/métodos , Neoplasias Experimentais/diagnóstico por imagem , Neoplasias Experimentais/cirurgia , Tomografia Computadorizada por Raios X/métodos , Vasoconstritores , Vasodilatadores , Animais , Linhagem Celular Tumoral , Quimioterapia Adjuvante , Humanos , Masculino , Neoplasias Experimentais/tratamento farmacológico , Prognóstico , Ratos , Resultado do Tratamento
16.
Exp Biol Med (Maywood) ; 234(1): 95-104, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18997100

RESUMO

Pluronic block copolymers have been shown to sensitize cancer cells resulting in an increased activity of antineoplastic agents. In the current study we examined a new application of Pluronic bioactivity in potentiating hyperthermia-induced cancer cell injury. DHD/K12/TRb rat adenocarcinoma cells were exposed to low-grade hyperthermia at 43 degrees C with or without Pluronic P85 or Pluronic L61. A range of Pluronic doses, pre-exposure and heat exposure durations were investigated, and the test conditions were optimized. Treatment efficacy was assessed by measurement of intracellular ATP and mitochondrial dehydrogenase activity. Both P85 and L61 in synergy with heat reduced cell viability appreciably compared to either heat or Pluronic alone. Under optimal conditions, P85 (10 mg/ml, 240 mins) combined with 15 mins heat reduced intracellular ATP to 60.1 +/- 3.5% of control, while heat alone and P85 without heat caused a negligible decrease in ATP of 1.2% and 3.8%, respectively. Similarly, cells receiving 120 mins pre-exposure of L61 (0.3 mg/ml) showed reduction in intracellular ATP to 14.1 +/- 2.1% of control. Again, heat or L61 pre-exposure alone caused a minor decrease in levels of intracellular ATP (1.5% and 4.4%, respectively). Comparable results were observed when viability was assessed by mitochondrial enzyme activity. Survival studies confirmed that the loss of viability translates to a long-term reduction in proliferative activity, particularly for L61 treated cells. Based on these results, we conclude that Pluronic is effective in improving hyperthermic cancer treatment in vitro by potentiating heat-induced cytotoxicity in a concentration and time dependent manner.


Assuntos
Adenocarcinoma/patologia , Hipertermia Induzida/métodos , Poloxâmero/toxicidade , Trifosfato de Adenosina/metabolismo , Animais , Sobrevivência Celular/efeitos dos fármacos , Cinética , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/patologia , Poloxaleno/toxicidade , Ratos , Fatores de Tempo
17.
Ann Biomed Eng ; 37(3): 552-64, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19085107

RESUMO

Blood flow is a key factor in the efficacy of radiofrequency (RF) ablation treatment of solid tumors. We hypothesized that vasoactive drugs can modulate tumor blood flow and thereby improve the outcome of this thermal ablation approach. To verify this hypothesis, we measured the tumor perfusion changes in response to phenylephrine (PE) and hydralazine (HYZ) using a CT perfusion method in a rat subcutaneous tumor model. The coagulation sizes induced by RF ablation alone, RF ablation with PE and RF ablation with HYZ were compared. Results demonstrated that HYZ produced a marked decrease in entire tumor and tumor rim blood flow of 31.1 and 29.1%; while PE insignificantly change tumor blood flow (5.1% decrease in whole tumor and 6.0% decrease in tumor rim). A markedly greater coagulation area (0.59 cm2 +/- 0.24) was observed when HYZ was administered before RF ablation. No difference was noted in the coagulation area induced by RF ablation alone or the combination of PE injection followed by RF ablation (0.29 cm2 +/- 0.13 vs. 0.30 cm2 +/- 0.18). Results suggest that HYZ decreases subcutaneous tumor blood flow and enhances the coagulation size induced by RF ablation. PE has little influence on tumor blood flow and does not improve ablation.


Assuntos
Adenocarcinoma/fisiopatologia , Adenocarcinoma/terapia , Velocidade do Fluxo Sanguíneo , Ablação por Cateter/métodos , Neovascularização Patológica/fisiopatologia , Vasoconstrição , Adenocarcinoma/irrigação sanguínea , Animais , Linhagem Celular Tumoral , Ratos
18.
Radiology ; 246(3): 796-803, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18309015

RESUMO

PURPOSE: To prospectively determine, in an animal tumor model, if the block copolymer Pluronic P85 (BASF, Shreveport, La) sensitizes cancer cells to hyperthermia and if intratumorally or intravenously administered copolymer improves the therapeutic outcome of radiofrequency (RF) ablation tumor treatment. MATERIALS AND METHODS: The effects of Pluronic P85 and mild hyperthermia in vitro were tested in DHD/K12/TRb rat colorectal carcinoma cells. Cells were incubated at 37 degrees C or 43 degrees C for 15-60 minutes with 0%, 7%, or 10% wt/wt Pluronic P85, and cell viability was assessed by using a mitochondrial enzyme assay. In vivo experiments were performed as approved by the Institutional Animal Care and Use Committee at Case Western Reserve University and according to all applicable guidelines on animal use. Bilateral subcutaneous tumors in rats were treated with either intratumoral (13 tumors) or intravenous (15 tumors) Pluronic P85 followed by ablation or with ablation alone (14 tumors) and were monitored for 14 days by using volumes estimated from caliper measurements of tumor diameter. Acute effects of Pluronic P85 on the size of ablation-induced coagulation were measured after 24 hours in additional tumors (six tumors each treated according to the protocol for the ablation-only, intratumoral injection, and intravenous injection groups). Statistical testing was performed by using linear regression analysis and two-sided t tests with a significance level of .05. RESULTS: At 43 degrees C, 7% and 10% Pluronic P85 reduced in vitro cell viability by 22% +/- 5 (standard error of the mean) (P < .001) and 28% +/- 5 (P < .001), respectively, compared with the viability of control cells. At day 14, the volume of tumors ablated after local and systemic Pluronic P85 pretreatment changed by -55% +/- 14 (P = .03) and -59% +/- 14 (P = .02), respectively, compared with an increase of 16% +/- 28 for tumors treated with ablation alone. Coagulation area at 24 hours was reduced by 44% relative to that in control tumors (P = .03) after intratumoral Pluronic P85 but was unchanged after systemic Pluronic P85. CONCLUSION: Tumor pretreatment with Pluronic P85 improved the outcome of RF ablation by decreasing the tumor volume and residual tumor in an experimental carcinoma model.


Assuntos
Ablação por Cateter , Neoplasias Colorretais/terapia , Poloxaleno/farmacologia , Animais , Linhagem Celular Tumoral , Quimioterapia Adjuvante , Neoplasias Colorretais/patologia , Terapia Combinada , Hipertermia Induzida , Injeções Intralesionais , Modelos Lineares , Transplante de Neoplasias , Poloxaleno/administração & dosagem , Estudos Prospectivos , Ratos
19.
Exp Biol Med (Maywood) ; 232(7): 950-7, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17609512

RESUMO

Pluronic, a poly(ethylene oxide)-poly(propylene oxide)-poly (ethylene oxide) block copolymer, has been shown to enhance the cytotoxic activity of anticancer drugs in various cell lines. In the current study the effect of Pluronic P85 (P85) and Pluronic L61 (L61) on the intratumoral chemotherapy of an experimental adenocarcinoma in rats was examined. A total of 120 subcutaneous tumors (4 per rat) were inoculated in 30 BDIX rats and were treated weekly for 4 weeks with intratumoral injection of carboplatin (CPt) alone or with either P85 or L61. Tumors were monitored weekly and were excised at the endpoint for histologic evaluation. The effect of Pluronic on levels of intracellular ATP was explored as a possible mechanism of sensitization. Results showed that tumors treated with low-dose CPt (2.8 mg/kg) and P85 or L61 exhibited significant reductions in tumor volume after 28 days relative to Day 0 (112.7% +/- 34.4%, n = 15; 131.3% +/- 55.6%, n = 8) compared with tumors treated with free drug (339.4% +/- 75.0%, n = 16). Control tumors treated with either P85 or L61 alone or with saline showed volume increases of 1079.4% +/- 143.6% (n = 16), 729.4% +/- 202.2% (n = 7), and 1119.2% +/- 6.1% (n = 16), respectively. Treatment with high-dose CPt (20.7 mg/kg) led to a 79.3% +/- 4.2% reduction in tumor volume, and no differences were noted with addition of P85 or L61. In vitro ATP measurements showed that 28.0 mg/kg of P85 significantly reduced levels of intracellular ATP to 44.7% +/- 1.5% of controls, whereas L61 at this concentration depleted ATP levels completely. Results confirm that Pluronic P85 and L61 act as potent sensitizers to carboplatin chemotherapy of the experimental colorectal carcinoma, leading to a significant reduction of tumor growth compared to carboplatin alone. ATP depletion is a possible mechanism for these observed differences.


Assuntos
Carboplatina/administração & dosagem , Neoplasias Colorretais/tratamento farmacológico , Poloxâmero/administração & dosagem , Trifosfato de Adenosina/metabolismo , Animais , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Humanos , Metástase Neoplásica , Transplante de Neoplasias , Ratos , Tensoativos/farmacologia , Fatores de Tempo
20.
J Biomed Mater Res A ; 80(2): 381-90, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17001645

RESUMO

Infection due to implanted cardiovascular biomaterials is a serious complication initiated by bacterial adhesion to the surface of the implant. The release of reactive oxygen species by neutrophils, particularly superoxide anion, is a well-known bactericidal mechanism. Additionally, nitric oxide (NO) has also been identified as an important cytotoxic mediator in acute and chronic inflammatory responses with enhanced NO production by upregulation of inducible nitric oxide synthase (iNOS). The interaction of NO and superoxide anion will result in the formation of peroxynitrite (OONO-), a potent cytotoxic oxidant. In this study, we have shown that biomaterial-induced neutrophil activation does not cause upregulation of iNOS and activation of iNOS-mediated pathways. However, NO and O2- production does occur over time upon adhesion to a biomaterial and is modulated by biomaterial surface chemistry. With no stimulus, the polyethylene oxide-modified polyurethane induced greater neutrophil activation than did the control as indicated by the increased production of NO and O2- over time. Adherent-stimulated neutrophils generally produced lower amounts of NO over time in comparison with unstimulated cells. Furthermore, there is no evidence of peroxynitrite activity in unstimulated neutrophils adherent to the Elasthane 80A. However, upon stimulation with adherent Staphylococcus epidermidis, peroxynitrite formation did occur. Our results suggest that bactericidal mechanisms in neutrophils involving NO generation (NOS pathway) are further compromised than O2- producing pathways (NADPH oxidase) upon exposure to biomaterials, resulting in a diminished microbial killing capacity, which can increase the probability of device-centered infections.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/química , Neutrófilos/citologia , Neutrófilos/metabolismo , Óxido Nítrico Sintase Tipo II/metabolismo , Espécies Reativas de Nitrogênio/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Antibacterianos , Adesão Celular , Humanos , Ativação de Neutrófilo , Neutrófilos/enzimologia , Ácido Peroxinitroso/análise , Ácido Peroxinitroso/metabolismo , Polietilenoglicóis/farmacologia , Poliuretanos/farmacologia , Staphylococcus/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...