Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Circ Cardiovasc Imaging ; 11(3): e007107, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29555835

RESUMO

BACKGROUND: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. METHODS AND RESULTS: WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. CONCLUSIONS: Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imageamento Tridimensional/métodos , Telemedicina/métodos , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
Eur Heart J Cardiovasc Imaging ; 19(4): 405-414, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28444153

RESUMO

Aims: To assess the use of downstream coronary angiography (ICA) and short-term safety of frontline coronary CT angiography (CTA) with selective CT-derived fractional flow reserve (FFRCT) testing in stable patients with typical angina pectoris. Methods and results: Between 1 January 2016 and 30 June 2016 all patients (N = 774) referred to non-emergent ICA or coronary CTA at Aarhus University Hospital on a suspicion of CAD had frontline CTA performed. Downstream testing and treatment within 3 months and adverse events ≥90 days were registered. Patients were divided into two groups according to the presence of typical angina pectoris, which according to local practice would have resulted in referral to ICA, (low-intermediate-risk, n = 593 [76%]; high-risk, n = 181 [24%]) with mean pre-test probability of CAD of 31 ± 16% and 67 ± 16%, respectively. Coronary CTA was performed in 745 (96%) patients in whom FFRCT was prescribed in 212 (28%) patients. In the high- vs. low-intermediate-risk group, ICA was cancelled in 75% vs. 91%. Coronary revascularization was performed more frequently in high-risk than in low-intermediate-risk patients, 76% vs. 52% (P = 0.03). Mean follow-up time was 157 ± 50 days. Serious clinical events occurred in four patients, but not in any patients with cancelled ICA by coronary CTA with selective FFRCT testing. Conclusion: Frontline coronary CTA with selective FFRCT testing in stable patients with typical angina pectoris in real-world practice is associated with a high rate of safe cancellation of planned ICAs.


Assuntos
Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Angina Pectoris/mortalidade , Doenças Assintomáticas , Causas de Morte , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida
3.
EuroIntervention ; 13(9): e1020-e1025, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-28691908

RESUMO

AIMS: Transcatheter valve-in-valve (VIV) implantation is usually discouraged in small surgical tissue valves. We report our first ten cases of fracturing small dysfunctional Mitroflow bioprostheses by high-pressure balloon dilatation to increase the internal diameter of the surgical valve before VIV (BF-VIV). METHODS AND RESULTS: BF-VIV was performed in 10 patients (mean age 84±4 years) with failing Mitroflow valves size 19 mm (n=3, threshold of fracture 15 atm) and 21 mm (n=7, threshold of fracture 13 atm). An Edwards SAPIEN 3 or XT 20 mm or 23 mm transcatheter valve was implanted inside the fractured Mitroflow bioprosthesis. The procedure improved aortic valve area (0.7±0.3 vs. 1.1±0.3 cm2, p=0.001), reduced peak aortic valve gradient (66±27 vs. 29±7 mmHg, p=0.002), resolved aortic regurgitation and improved patients' NYHA functional class (p=0.005). One patient had a minor stroke with complete resolution of symptoms and another patient required a pacemaker due to AV block. All patients were still alive at the end of follow-up (438±255 days). CONCLUSIONS: Initial experience with transcatheter BF-VIV suggests that this method is feasible and safe, and that it improves aortic valve haemodynamics and clinical functional capacity. BF-VIV is a promising alternative to repeat surgery in patients with small failing Mitroflow bioprostheses.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Falha de Prótese , Reoperação , Estudos Retrospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-27412869

RESUMO

BACKGROUND: Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. METHODS AND RESULTS: The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05). CONCLUSIONS: The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Países Escandinavos e Nórdicos , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Aço Inoxidável , Fatores de Tempo , Resultado do Tratamento
5.
Open Heart ; 3(1): e000427, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27403331

RESUMO

OBJECTIVE: It remains unknown whether complete revascularisation is optimally performed in patients with ST segment elevation myocardial infarction (STEMI) during the index or at staged procedures. The aims of this study were to quantify the number of primary percutaneous coronary intervention (PCI) procedures in which non-culprit lesions needed further evaluation, to determine the consequence of the re-evaluation and to quantify adverse cardiac events during the waiting time for re-evaluation and intervention. METHODS: The study was observational and retrospective and included all patients with STEMI treated with primary PCI during 1 year at our centre. RESULTS: Among the 507 patients with STEMI, 374 were considered sufficiently treated with culprit lesion PCI only. Complete primary multivessel revascularisation was performed in 11 patients. Non-culprit lesion re-evaluation was planned for 122 patients (24%). Of these 122 patients, 3 patients died during their index admission. Follow-up data were not available for 3 patients. Among the 116 patients, 187 non-culprit lesions were re-evaluated and 77 patients (66.4%) underwent revascularisation with treatment of 119 lesions (63.3%). Re-evaluation was performed after a median of 30 days (25th centile: 9 days, 75th centile: 35 days). During the waiting time for re-evaluation, two patients underwent a new primary PCI due to stent thrombosis of the index culprit lesion. CONCLUSIONS: Staged re-evaluation of non-culprit lesions observed in patients with STEMI was required in 24% of a primary PCI cohort. Intervention was performed in 66.4% of patients scheduled for re-evaluation. We observed no adverse events related to the non-culprit lesions during the waiting time for a staged re-evaluation or intervention.

7.
Catheter Cardiovasc Interv ; 86(7): 1161-7, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25640050

RESUMO

OBJECTIVE: We aimed to compare angiographic and clinical outcomes after the implantation of everolimus-eluting (EES) and sirolimus-eluting (SES) stents in patients with diabetes. BACKGROUND: There are limited data on long-term outcome after EES vs SES implantation in diabetic patients. METHODS: We randomized 213 patients with diabetes and coronary artery disease to EES (n = 108) or SES (n = 105) implantation. Angiographic follow-up was performed 10 months after the index procedure and all patients were followed clinically for 4 years. The primary endpoint was angiographic in-stent late luminal loss at 10-month follow-up. Secondary endpoints included angiographic restenosis rate, the need for target lesion revascularization (TLR) and major adverse cardiac events (MACE; defined as cardiac death, myocardial infarction, definite stent thrombosis, or TLR) at 4-year follow-up. RESULTS: At 10-month angiographic follow-up, in-stent late lumen loss was 0.20 ± 0.53 mm and 0.11 ± 0.49 mm (P = 0.28), and angiographic restenosis rate was 3.8% and 5.2% (P = 0.72) in the EES and SES groups, respectively. At 4-year clinical follow-up, MACE had occurred in 22 (20.4%) patients in the EES group and 25 (23.8%) patients in SES group (HR 0.84, 95% CI 0.47-1.49; P = 0.55), with TLR performed in 6 (5.6%) and 10 (9.5%) patients in the two groups (HR 0.57, 95% CI 0.21-1-58; P = 0.28). CONCLUSION: EES and SES had comparable 10-month angiographic and 4-year clinical outcomes in patients with diabetes mellitus and coronary artery disease.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Angiopatias Diabéticas/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/mortalidade , Dinamarca , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Lancet ; 385(9977): 1527-35, 2015 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-25601789

RESUMO

BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448. FINDINGS: Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months. INTERPRETATION: The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients. FUNDING: Medtronic Cardiovascular and Biosensors Interventional Technologies.


Assuntos
Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Implantes Absorvíveis , Idoso , Materiais Revestidos Biocompatíveis , Dinamarca , Desenho de Equipamento , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/mortalidade , Polímeros , Sirolimo/administração & dosagem , Resultado do Tratamento
9.
Int J Cardiol ; 182: 272-8, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25585362

RESUMO

BACKGROUND: Intracoronary imaging provides accurate lesion delineation and precise measurements for sizing and positioning of coronary stents. During percutaneous coronary intervention (PCI), it may be challenging to identify corresponding segments between intracoronary imaging and angiography. Computer based online co-registration may aid the target segment identification. METHODS: The DOCTOR fusion study was a prospective, single arm, observational study including patients admitted for elective PCI. Optical coherence tomography (OCT) was acquired pre-stent implantation for sizing of stents. The operator subsequently indicated on the angiogram the target area as identified by OCT. Computer based co-registration was performed on-line immediately after pre-stent acquisition to assess feasibility. The cumulated numerical difference between operator based, and computer based co-registration was assessed as the "Operator Registration Error". The operator implanted the stent blind to the co-registrated angiogram. The difference between the co-registered stent border positions and the actual stent deployment border positions was the "Geographic Miss Distance". RESULTS: Twenty-two patients were included in the study. Two patients were excluded due to missing pre or post-OCT acquisitions. Online co-registration pre-stenting was successful in all analyzed cases. The mean "Operator Registration Error" was 5.4±3.5mm. The mean "Geographic Miss Distance" was 5.4±2.6mm. Without access to the computer-based co-registration, segments of the target lesion indicated on OCT were left uncovered by stent in 14 patients (70%). CONCLUSION: Computer based online co-registration of OCT and angiography is feasible. Frequent inaccuracies in operator based registration indicate that computer aided co-registration may reduce errors in corresponding OCT findings to the angiogram.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Monitorização Intraoperatória , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 14: 100, 2014 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-25125079

RESUMO

BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. RESULTS: Discontinuation of clopidogrel within the first 3 months after stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were associated with smaller, not statistically significant, increases in MACE rates. Among patients who discontinued clopidogrel, MACE rates were highest within the first 2 months after discontinuation. CONCLUSIONS: Discontinuation of clopidogrel was associated with an increased rate of MACE among patients treated with drug-eluting stents. The increase was statistically significant within the first 3 months after drug-eluting stent implantation but not after 3 to 12 months.


Assuntos
Stents Farmacológicos , Adesão à Medicação , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Ticlopidina/análogos & derivados , Idoso , Clopidogrel , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Trombose Coronária/prevenção & controle , Dinamarca , Esquema de Medicação , Prescrições de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Ticlopidina/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
11.
Lancet ; 383(9934): 2047-2056, 2014 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-24631162

RESUMO

BACKGROUND: In head-to-head comparisons of coronary drug-eluting stents, the primary endpoint is traditionally assessed after 9-12 months. However, the optimum timepoint for this assessment remains unclear. In this study, we assessed clinical outcomes at up to 5 years' follow-up in patients who received two different types of drug-eluting stents. METHODS: We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone allocation service. The primary endpoint of the SORT OUT III study was a composite of major adverse cardiac events-cardiac death, myocardial infarction, and target vessel revascularisation-at 9 months' follow-up. In this study, endpoints included the occurrence of major adverse cardiac events and definite stent thrombosis at follow-up times of up to 5 years. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT00660478. FINDINGS: We randomly allocated 1162 patients to receive the zotarolimus-eluting stent and 1170 to the sirolimus-eluting stent. At 5-year follow-up, rates of major adverse cardiac events were similar in patients treated with both types of stents (zotarolimus-eluting stents 197/1162 [17.0%] vs sirolimus-eluting stents 182/1170 [15.6%]; odds ratio [OR] 1.10, 95% CI 0.88-1.37; p=0.40). This finding was indicative of the directly contrasting results for rates of major adverse cardiac events at 1-year follow up (zotarolimus 93/1162 [8.0%] vs sirolimus 46/1170 [3.9%]; OR 2.13, 95% CI 1.48-3.07; p<0.0001) compared with those at follow-up between 1 and 5 years (104 [9.0%] vs 136 [11.6%]; OR 0.78, 95% CI 0.59-1.02; p=0.071). At 1-year follow-up, definite stent thrombosis was more frequent after implantation of the zotarolimus-eluting stent (13/1162 [1.1%]) than the sirolimus-eluting stent (4/1170 [0.3%]; OR 3.34, 95% CI 1.08-10.3; p=0.036), whereas the opposite finding was recorded for between 1 and 5 years' follow-up (zotarolimus-eluting stent 1/1162 [0.1%] vs sirolimus-eluting stent 21/1170 [1.8%], OR 0.05, 95% CI 0.01-0.36; p=0.003). 26 of 88 (30%) target lesion revascularisations in the zotarolimus-eluting stent group occurred between 1 and 5 years' follow-up, whereas 54 of 70 (77%) of those in the sirolimus-eluting stent group occurred during this follow-up period. INTERPRETATION: The superiority of sirolimus-eluting stents compared with zotarolimus-eluting stents at 1-year follow-up was lost after 5 years. The traditional 1-year primary endpoint assessment therefore might be insufficient to predict 5-year clinical outcomes in patients treated with coronary drug-eluting stent implantation. FUNDING: Cordis and Medtronic.


Assuntos
Citostáticos/administração & dosagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Idoso , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Trombose Coronária/etiologia , Citostáticos/efeitos adversos , Citostáticos/uso terapêutico , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Projetos de Pesquisa , Método Simples-Cego , Sirolimo/efeitos adversos , Sirolimo/uso terapêutico , Fatores de Tempo , Resultado do Tratamento
12.
Lancet ; 381(9867): 661-9, 2013 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-23374649

RESUMO

BACKGROUND: Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS: This randomised, multicentre, all-comer, non-inferiority trial was undertaken at three sites across western Denmark. Eligible patients were aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion (>50% diameter stenosis). We randomly assigned patients (1:1) using an independently managed computer-generated allocation sequence to receive either a biolimus-eluting biodegradable polymer stent (Nobori, Terumo, Tokyo, Japan) or a sirolimus-eluting permanent polymer stent (Cypher Select Plus, Cordis, Johnson & Johnson, Warren, NJ, USA). The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation) at 9 months, analysed by intention to treat (non-inferiority margin of 0·02). This trial is registered with ClinicalTrials.gov, number NCT01254981. FINDINGS: From July, 2009, to January, 2011, we assigned 1229 patients (1532 lesions) to receive the biolimus-eluting stent and 1239 (1555 lesions) to receive the sirolimus-eluting stent. One patient was lost to follow-up because of emigration. Intention-to-treat analysis showed that 50 (4·1%) patients who were assigned the biolimus-eluting stent and 39 (3·1%) who were assigned the sirolimus-eluting stent met the primary endpoint (risk difference 0·9% [upper limit of one-sided 95% CI 2·1%]; p(non-inferiority)=0·06). Significantly more patients in the biolimus-eluting stent group had definite stent thrombosis at 12 months than did those in the sirolimus-eluting stent group (9 [0·7%] vs 2 [0·2%], risk difference 0·6% [95% CI 0·0-1·1]; p=0·034). Per-protocol analysis showed that 45 (3·8%) of 1193 patients who received a biolimus-eluting stent and 39 (3·2%) of 1208 who received a sirolimus-eluting stent met the primary endpoint (risk difference 0·5% [upper limit of one-sided 95% CI 1·8%]; p(non-inferiority)=0·03). INTERPRETATION: At 1 year follow-up, the biodegradable polymer biolimus-eluting Nobori stent did not improve clinical results compared with a first-generation sirolimus-eluting stent. We will need to obtain long-term data before we can make recommendations for the role of this biolimus-eluting stent in routine clinical practice. FUNDING: Terumo and Cordis (Johnson & Johnson).


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Síndrome Coronariana Aguda/mortalidade , Idoso , Aspirina/uso terapêutico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/epidemiologia , Trombose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros , Retratamento/estatística & dados numéricos
13.
J Am Coll Cardiol ; 60(13): 1140-7, 2012 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-22958957

RESUMO

OBJECTIVES: There are limited head-to-head randomized data on patient-related versus stent-related outcomes for everolimus-eluting stents (EES) and sirolimus-eluting stents (SES). BACKGROUND: In the SORT OUT IV (Scandinavian Organization for Randomized Trials With Clinical Outcome IV) trial, comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the SES at 9 months. METHODS: The primary endpoint was a composite: cardiac death, myocardial infarction (MI), definite stent thrombosis, or target vessel revascularization. Safety and efficacy outcomes at 2 years were further assessed with specific focus on patient-related composite (all death, all MI, or any revascularization) and stent-related composite outcomes (cardiac death, target vessel MI, or symptom-driven target lesion revascularization). A total of 1,390 patients were assigned to receive the EES, and 1,384 patients were assigned to receive the SES. RESULTS: At 2 years, the composite primary endpoint occurred in 8.3% in the EES group and in 8.7% in the SES group (hazard ratio [HR]: 0.94, 95% confidence interval [CI]: 0.73 to 1.22). The patient-related outcome: 15.0% in the EES group versus 15.6% in the SES group, (HR: 0.95, 95% CI: 0.78 to 1.15), and the stent-related outcome: 5.2% in the EES group versus 5.3% in the SES group (HR: 0.97, 95% CI: 0.70 to 1.35) did not differ between groups. Rate of definite stent thrombosis was lower in the EES group (0.2% vs. 0.9%, (HR: 0.23, 95% CI: 0.07 to 0.80). CONCLUSIONS: At 2-year follow-up, the EES was found to be noninferior to the SES with regard to both patient-related and stent-related clinical outcomes.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imunossupressores/uso terapêutico , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Idoso , Doença da Artéria Coronariana/mortalidade , Morte , Dinamarca , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Revascularização Miocárdica/estatística & dados numéricos , Método Simples-Cego , Sirolimo/efeitos adversos , Trombose/etiologia , Resultado do Tratamento
14.
JACC Cardiovasc Interv ; 5(8): 812-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22917452

RESUMO

OBJECTIVES: This study sought to examine the 3-year clinical outcomes in patients treated with the Endeavor (Medtronic, Santa Rosa, California) zotarolimus-eluting stent (ZES) or the Cypher (Cordis, Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) in routine clinical practice. BACKGROUND: The long-term clinical outcome in patients treated with ZES in comparison with SES is unclear. METHODS: The authors randomized 2,332 patients to ZES (n = 1,162) or SES (n = 1,170) implantation. Endpoints included major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction, or target vessel revascularization; the individual endpoints of MACE; and definite stent thrombosis. RESULTS: At 3-year follow-up, the MACE rate was higher in patients treated with ZES than in patients treated with SES (148 [12.9%] vs. 116 [10.1%]; hazard ratio [HR]: 1.33, 95% confidence interval [CI]: 1.04 to 1.69; p = 0.022). Target vessel revascularization was more frequent in the ZES group compared with the SES group (103 [9.1%] vs. 76 [6.7%]; HR: 1.40, 95% CI: 1.04 to 1.89; p = 0.025), whereas the occurrence of myocardial infarction (3.8% vs. 3.3%) and cardiac death (2.8% vs. 2.8%) did not differ significantly. Although the rate of definite stent thrombosis was similar at 3-year follow-up (1.1% vs. 1.4%), very late (12 to 36 months) definite stent thrombosis occurred in 0 (0%) patients in the ZES group versus 12 (1.1%) patients in the SES group (p = 0.0005). CONCLUSIONS: Although the 3-year MACE rate is higher in patients treated with ZES versus SES, our data highlight a late safety problem concerning definite stent thrombosis with the use of SES. This finding underscores the importance of long-term follow-up in head-to-head comparisons of drug-eluting stents. (Randomized Clinical Comparison of the Endeavor and the Cypher Coronary Stents in Non-selected Angina Pectoris Patients [SORT OUT III]; NCT00660478).


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
15.
Circulation ; 125(10): 1246-55, 2012 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-22308301

RESUMO

BACKGROUND: Among drug-eluting stents released to date, the sirolimus-eluting stent has demonstrated the least amount of late lumen loss, but its efficacy and safety have not been compared head-to-head with the next-generation everolimus-eluting stent. METHODS AND RESULTS: The Scandinavian Organization for Randomized Trials with Clinical Outcome IV (SORT OUT IV) trial was a randomized multicenter, single-blind, all-comer, 2-arm, noninferiority trial comparing the everolimus-eluting stent with the sirolimus-eluting stent in patients with coronary artery disease. The primary end point was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularization) parameters. The noninferiority criterion was a risk difference of 0.015. Intention-to-treat analyses were done at 9- and 18-month follow-ups. A total of 1390 patients were assigned to receive the everolimus-eluting stent and 1384 patients to the sirolimus-eluting stent. At the 9-month follow-up, 68 patients (4.9%) treated with the everolimus-eluting stent compared with 72 patients (5.2%) treated with the sirolimus-eluting stent experienced the primary end point (hazard ratio, 0.94; 95% confidence interval, 0.67-1.31; P for noninferiority=0.01). At the 18-month follow-up, this differential remained: 99 patients (7.2%) treated with the everolimus-eluting stent versus 105 (7.6%) treated with the sirolimus-eluting stent (hazard ratio, 0.94; 95% confidence interval, 0.71-1.23). At the 9-month follow-up, the rate of definite stent thrombosis was higher in the sirolimus-eluting group (2 patients [0.1%] versus 9 patients [0.7%]; hazard ratio, 0.22; 95% confidence interval, 0.05-1.02). At the 18-month follow-up, this difference was sustained (3 patients [0.2%] versus 12 patients [0.9%]; hazard ratio, 0.25; 95% confidence interval, 0.07-0.88). CONCLUSION: The everolimus-eluting stent was found to be noninferior to the sirolimus-eluting stent. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00552877.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/mortalidade , Reestenose Coronária/prevenção & controle , Trombose Coronária/mortalidade , Trombose Coronária/prevenção & controle , Everolimo , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
16.
Eur Heart J Cardiovasc Imaging ; 13(5): 433-43, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22207343

RESUMO

BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI) pre-infarction angina, pre-procedural TIMI flow and collateral flow to the myocardium supplied by the infarct related artery are suggested to be cardioprotective. We evaluated the effect of these factors on myocardial salvage index (MSI) and infarct size adjusting for area at risk in patients with STEMI treated with primary percutaneous coronary intervention. METHODS AND RESULTS: Cardiac magnetic resonance (CMR) was used to measure myocardial area at risk within 1-7 days and final infarct size 90 ± 21 days after the STEMI in 200 patients. MSI was calculated as (area-at-risk infarct size) / area-at-risk. Patients with pre-infarction angina had a median MSI of 0.80 (IQR 0.67 to 0.86) versus 0.72 (0.61 to 0.80) in those without pre-infarction angina, P = 0.004). In a regression analysis of the infarct size plotted against the area-at-risk there was a strong trend that the line for the pre-infarction angina group was below the one for the non-angina group (P = 0.05). Patients with pre-procedural TIMI flow 0/1, 2 and 3 had a median MSI of (0.69 (IQR 0.59 to 0.76), 0.78 (0.68 to 0.86) and 0.85 (0.77 to 0.91), respectively (P<0.001). Collateral flow did not change MSI (P = 0.45) nor area-at-risk (P = 0.40) and no significant difference in infarct size adjusted for area at risk (P = 0.25) was observed. CONCLUSIONS: Pre-infarction angina increases MSI in patients with STEMI supporting the theory that pre-infarction angina leads to ischemic preconditioning. As opposed to the presence of angiographically visible collateral flow to the infarct area pre-procedural TIMI flow is strongly associated with MSI.


Assuntos
Angina Pectoris/patologia , Circulação Colateral , Hemodinâmica , Imagem Cinética por Ressonância Magnética/instrumentação , Infarto do Miocárdio/patologia , Terapia Trombolítica , Angina Pectoris/tratamento farmacológico , Angina Pectoris/terapia , Angiografia Coronária , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/terapia , Miocárdio , Análise de Regressão , Medição de Risco/métodos , Estatística como Assunto , Estatísticas não Paramétricas , Fatores de Tempo
17.
Eur Heart J ; 33(12): 1491-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21920963

RESUMO

AIMS: Exenatide, a glucagon-like-peptide-1 analogue, increases myocardial salvage in experimental settings with coronary occlusion and subsequent reperfusion. We evaluated the cardioprotective effect of exenatide at the time of reperfusion in patients with ST-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (pPCI). METHODS AND RESULTS: A total of 172 patients with STEMI and Thrombolysis in Myocardial Infarction flow 0/1 were randomly assigned to exenatide or placebo (saline) intravenously. Study treatment was commenced 15 min before intervention and maintained for 6 h after the procedure. The primary endpoint was salvage index calculated from myocardial area at risk (AAR), measured in the acute phase, and final infarct size measured 90 ± 21 days after pPCI by cardiac magnetic resonance (CMR). In 105 patients evaluated with CMR, a significantly larger salvage index was found in the exenatide group than in the placebo group (0.71 ± 0.13 vs. 0.62 ± 0.16; P= 0.003). Infarct size in relation to AAR was also smaller in the exenatide group (0.30 ± 0.15 vs. 0.39 ± 0.15; P= 0.003). In a regression analysis, there was a significant correlation between the infarct size and the AAR for both treatment groups and an analysis of covariance showed that datapoints in the exenatide group lay significantly lower than for the placebo group (P= 0.011). There was a trend towards smaller absolute infarct size in the exenatide group (13 ± 9 vs. 17 ± 14 g; P= 0.11). No difference was observed in left ventricular function or 30-day clinical events. No adverse effects of exenatide were observed. CONCLUSION: In patients with STEMI undergoing pPCI, administration of exenatide at the time of reperfusion increases myocardial salvage.


Assuntos
Cardiotônicos/uso terapêutico , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Peptídeos/uso terapêutico , Peçonhas/uso terapêutico , Idoso , Angioplastia Coronária com Balão/métodos , Método Duplo-Cego , Exenatida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Lancet ; 375(9720): 1090-9, 2010 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-20231034

RESUMO

BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five percutaneous coronary intervention centres between January, 2006, and August, 2007. Computer-generated block randomisation and a telephone allocation service were used to randomly assign patients to receive the zotarolimus-eluting or the sirolimus-eluting stent. Data for follow-up were obtained from national Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial is registered with ClinicalTrials.gov, number NCT00660478. FINDINGS: 1162 patients (1619 lesions) were assigned to receive the zotarolimus-eluting stent, and 1170 patients (1611 lesions) to receive the sirolimus-eluting stent. 67 patients (72 lesions) had stent failure, and six patients were lost to follow-up. All randomly assigned patients were included in analyses at 9-month follow-up; 2200 patients (94%) had completed 18-month follow-up by the time of our assessment. At 9 months, the primary endpoint had occurred in a higher proportion of patients treated with the zotarolimus-eluting stent than in those treated with the sirolimus-eluting stent (72 [6%] vs 34 [3%]; HR 2.15, 95% CI 1.43-3.23; p=0.0002). At 18-month follow-up, this difference was sustained (113 [10%] vs 53 [5%]; 2.19, 1.58-3.04; p<0.0001). For patients receiving the zotarolimus-eluting stent and those receiving the sirolimus-eluting stent, all cause-mortality was similar at 9-month follow-up (25 [2%] vs 18 [2%]; 1.40, 0.76-2.56; p=0.28), but was significantly different at 18-month follow-up (51 [4%] vs 32 [3%]; 1.61, 1.03-2.50; p=0.035). INTERPRETATION: The sirolimus-eluting stent is superior to the zotarolimus-eluting stent for patients receiving routine clinical care. FUNDING: Cordis and Medtronic.


Assuntos
Doença das Coronárias/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão , Reestenose Coronária/prevenção & controle , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Retratamento , Método Simples-Cego , Sirolimo/efeitos adversos , Trombose/etiologia , Resultado do Tratamento
19.
J Nucl Cardiol ; 16(5): 784-91, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19521742

RESUMO

AIM: Distal embolization during primary percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction (STEMI) may result in reduced myocardial perfusion, infarct extension and impaired prognosis. In a prospective randomized trial, we assessed the effect of routine filterwire distal protection on scintigraphic estimated infarct size. METHODS AND RESULTS: The effect of routine filterwire distal protection was evaluated in 344 patients with STEMI <12 hours undergoing primary PCI. Patients were randomized to distal protection with a filterwire or standard PCI. The primary endpoint was myocardial infarct size measured by Sestamibi SPECT after 30 days (%). Secondary endpoints included myocardial salvage, ST-segment resolution (STR), myocardial biomarker release and major adverse cardiac and cerebral events. Baseline characteristics including area at risk (estimated by Sestamibi SPECT) were similar. Final infarct size was not statistically different in the distal protection and the control groups (median [IQR], 6% [1-19] and 5% [1-14], P = .23). Also, secondary endpoints were similar in the two treatment groups. CONCLUSION: Distal protection with a filterwire performed as routine therapy in primary PCI for STEMI did not reduce myocardial infarct size. The study does not support routine use of distal protection in primary PCI.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Embolização Terapêutica/mortalidade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Terapia Combinada/mortalidade , Dinamarca/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Cintilografia , Medição de Risco/métodos , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida
20.
J Am Coll Cardiol ; 53(8): 658-64, 2009 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-19232897

RESUMO

OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST), myocardial infarction (MI), and death. METHODS: A total of 12,395 consecutive patients with coronary intervention and stent implantation recorded in the Western Denmark Heart Registry from January 2002 through June 2005 were followed up for 2 years. Data on death and MI were ascertained from national medical databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1.15), and 1.30% in PES patients (adjusted RR: 1.82, 95% CI: 1.13 to 2.94). The incidence of MI was 3.8% in BMS-treated patients, 4.5% in DES-treated patients (adjusted RR: 1.24, 95% CI: 1.02 to 1.51), 4.1% in SES-treated patients (adjusted RR: 1.15, 95% CI: 0.91 to 1.47), and 5.3% in PES-treated patients (adjusted RR: 1.38, 95% CI: 1.06 to 1.81). Whereas overall 2-year adjusted mortality was similar in the BMS and the 2 DES stent groups, 12- to 24-month mortality was higher in patients treated with PES (RR 1.46, 95% CI: 1.02 to 2.09). Target lesion revascularization was reduced in both DES groups. CONCLUSIONS: During 2 years of follow-up, patients treated with PES had an increased risk of ST and MI compared with those treated with BMS and SES. Mortality after 12 months was also increased in PES patients.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Imunossupressores , Paclitaxel , Sirolimo , Stents , Idoso , Doença das Coronárias/mortalidade , Doença das Coronárias/terapia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Stents/efeitos adversos , Trombose/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...