Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Biomed Eng ; 5(7): 772-782, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33941897

RESUMO

Continuous detection of raised intraocular pressure (IOP) could benefit the monitoring of patients with glaucoma. Current contact lenses with embedded sensors for measuring IOP are rigid, bulky, partially block vision or are insufficiently sensitive. Here, we report the design and testing in volunteers of a soft and transparent contact lens for the quantitative monitoring of IOP in real time using a smartphone. The contact lens incorporates a strain sensor, a wireless antenna, capacitors, resistors, stretchable metal interconnects and an integrated circuit for wireless communication. In rabbits, the lens provided measurements that match those of a commercial tonometer. In ten human participants, the lens proved to be safe, and reliably provided accurate quantitative measurements of IOP without inducing inflammation.


Assuntos
Pressão Intraocular/fisiologia , Monitorização Fisiológica/métodos , Adulto , Animais , Bovinos , Telefone Celular , Lentes de Contato , Feminino , Humanos , Monitorização Fisiológica/instrumentação , Impressão Tridimensional , Coelhos , Tecnologia sem Fio
2.
J Physiol Anthropol ; 39(1): 30, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33004082

RESUMO

BACKGROUND: Maintaining a good level of physical fitness from engaging in regular exercise is important for the treatment and prevention of metabolic syndrome (MetS). However, which components constitutive of physical fitness confer the greatest influence remains controversial. This retrospective cross-sectional study aimed to investigate the association between MetS and physical fitness components including cardiorespiratory fitness, muscle strength, flexibility, and agility and to identify which physical fitness components have the largest influence on MetS. METHODS: A total of 168 Japanese adult males aged 25-64 years were allocated into non-MetS, pre-MetS, and MetS groups according to the criteria recommended by the Japanese Society of Internal Medicine. Anthropometric measurement of body composition by whole-body dual-energy X-ray absorptiometry and measures related to MetS, including waist circumference, triglyceride level, high-density lipoprotein cholesterol level, blood pressure, glucose level, and physical fitness components, were assessed. For evaluation of cardiorespiratory fitness, muscle strength, flexibility, agility, and balance, maximal oxygen consumption (VO2peak) and oxygen uptake at anaerobic threshold (VO2AnT), handgrip strength and vertical jumping, trunk extension and flexion, stepping side to side, and single-leg balance task with the eyes closed were assessed, respectively. RESULTS: A progressive tendency of increasing body weight, body mass index, whole-body lean and fat mass, percentage of whole-body fat mass, trunk lean and fat mass, percentage of trunk fat mass, arm fat mass, waist circumference, triglyceride level, systolic and diastolic blood pressure, and blood glucose level from the non-MetS group to the MetS group was significant (P < 0.05). Conversely, the cardiorespiratory endurance parameters VO2peak and VO2AnT and the high-density lipoprotein cholesterol level showed a progressively decreasing tendency across the groups (P < 0.01). In addition, a VO2peak below 29.84 ml·kg·min-1 (P = 0.028) and VO2AnT below 15.89 ml·kg·min-1 (P = 0.011) were significant risk components for pre-MetS and MetS. However, there was no significant tendency with respect to muscle strength, agility, and flexibility. CONCLUSION: Cardiorespiratory fitness is strongly linked to metabolic syndrome among physical fitness components.


Assuntos
Aptidão Cardiorrespiratória/fisiologia , Síndrome Metabólica/fisiopatologia , Adulto , Antropologia Física , Composição Corporal/fisiologia , Estudos Transversais , Humanos , Masculino , Síndrome Metabólica/epidemiologia , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Aptidão Física/fisiologia , Estudos Retrospectivos
3.
Sci Adv ; 6(28): eabb2891, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32923592

RESUMO

Despite various approaches to immunoassay and chromatography for monitoring cortisol concentrations, conventional methods require bulky external equipment, which limits their use as mobile health care systems. Here, we describe a human pilot trial of a soft, smart contact lens for real-time detection of the cortisol concentration in tears using a smartphone. A cortisol sensor formed using a graphene field-effect transistor can measure cortisol concentration with a detection limit of 10 pg/ml, which is low enough to detect the cortisol concentration in human tears. In addition, this soft contact lens only requires the integration of this cortisol sensor with transparent antennas and wireless communication circuits to make a smartphone the only device needed to operate the lens remotely without obstructing the wearer's view. Furthermore, in vivo tests using live rabbits and the human pilot experiment confirmed the good biocompatibility and reliability of this lens as a noninvasive, mobile health care solution.

4.
Nano Lett ; 20(3): 1517-1525, 2020 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-31750664

RESUMO

Intraocular islet transplantation was investigated as a new procedure to treat diabetes. The development of this procedure requires close monitoring of the function of both eye and islet graft. We developed a soft, smart contact lens to monitor the intraocular pressure and applied this for noninvasive monitoring in association with the intraocular islet transplantation in diabetes. A strain sensor inside the lens can detect detailed changes in intraocular pressure by focusing the strain only in the desired, selective area of the contact lens. In addition, this smart contact lens can transmit the real-time value of the intraocular pressure wirelessly using an antenna. The wireless measurement of intraocular pressure that was obtained using this contact lens had a high correlation with the intraocular pressure measured by a rebound tonometer, thereby proving the good accuracy of the contact lens sensor. In the initial period, a slight elevation of intraocular pressure was observed, but the pressure returned to normal in the initial period after the transplantation. This type of monitoring will provide important information on potential changes in the intraocular pressure associated with the transplantation procedure, and it enables appropriate clinical safety steps to be taken, if needed.


Assuntos
Câmara Anterior , Lentes de Contato Hidrofílicas , Pressão Intraocular , Transplante das Ilhotas Pancreáticas , Animais , Câmara Anterior/fisiopatologia , Câmara Anterior/cirurgia , Monitorização Fisiológica , Ratos , Ratos Endogâmicos Lew
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...