1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21260618

RESUMO

The World Health Organization (WHO) has highlighted the importance of an international standard (IS) for SARS-CoV-2 neutralizing antibody titer detection, with the aim of calibrating different diagnostic techniques. In this study, IS was applied to calibrate neutralizing antibody titers (IU/mL) and binding antibody titers (BAU/mL) in response to SARS-CoV-2 vaccines. Serum samples were collected from participants receiving the Moderna (n = 20) and Pfizer (n = 20) vaccines at three time points: pre-vaccination, after one dose, and after two doses. We obtained geometric mean titers of 1404.16 and 928.75 IU/mL for neutralizing antibodies after two doses of the Moderna and Pfizer vaccines, respectively. These values provide an important baseline for vaccine development and the implementation of non-inferiority trials. We also compared three commercially available kits from Roche, Abbott, and MeDiPro for the detection of COVID-19 antibodies based on binding affinity to S1 and/or RBD. Our results demonstrated that antibody titers measured by commercial assays are highly correlated with neutralizing antibody titers calibrated by IS.

2.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-631046

RESUMO

We report a case of symptomatic bradycardia caused by consumption of a Chinese herbal medicine which was initially undisclosed to the attending emergency physician. The scientific name of the herb is Panax japonicus. Electrocardiogram revealed sinus bradycardia. Laboratory tests were normal except for the detection of a high serum digoxin level. Further interrogation of the patient eventually disclosed ingestion of the herb which, however, did not contain any digoxin. Other active ingredients in the herb include various types of ginsenoside. These are digoxin-like substances that had caused the observed false-positive detection of digoxin by fluorescence polarization immunoassay due to cross-reactivity. Our case-report provides an important insight about a blind-spot in the field of laboratory medicine (clinical pathology), namely, the false positive detection of digoxin due to crossreactivity in the immunoassay when we come across digoxin-like substances in clinical scenarios, which has barely received attention in the medical literature. It also conveys a clear educational message that with full understanding of the laboratory methodology and its mechanistic rationale there are actually some tricks-of-the-trade that allow us to optimize the specificity of the biochemical tests and the treatment of digoxin-like substances overdose.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...