Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxics ; 10(1)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35051062

RESUMO

Assessing the toxicity of new biomaterials dedicated to bone regeneration can be difficult. Many reports focus only on a single toxicity parameter, which may be insufficient for a detailed evaluation of the new material. Moreover, published data frequently do not include control cells exposed to the environment without composite or its extract. Here we present the results of two assays used in the toxicological assessment of materials' extracts (the integrity of the cellular membrane and the mitochondrial activity/proliferation), and the influence of different types of controls used on the obtained results. Results obtained in the cellular membrane integrity assay showed a lack of toxic effects of all tested extracts, and no statistical differences between them were present. Control cells, cells incubated with chitosan extract or chitosan-bioglass extract were used as a reference in proliferation calculations to highlight the impact of controls used on the result of the experiment. The use of different baseline controls caused variability between obtained proliferation results, and influenced the outcome of statistical analysis. Our findings confirm the thesis that the type of control used in an experiment can change the final results, and it may affect the toxicological assessment of biomaterial.

2.
Chem Biodivers ; 18(2): e2000883, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33427369

RESUMO

Herpesviruses are the most prevalent viruses that infect the human and animal body. They can escape a host immune response in numerous ways. One way is to block the TAP complex so that viral peptides, originating from proteasomal degradation, cannot be transported to the endoplasmic reticulum. As a result, a reduced number of MHC class I molecules appear on the surface of infected cells and, thus, the immune system is not efficiently activated. BoHV-1-encoded UL49.5 protein is one such TAP transporter inhibitor. This protein binds to TAP in such a way that its N-terminal fragment interacts with the loops of the TAP complex, and the C-terminus stimulates proteasomal degradation of TAP. Previous studies have indicated certain amino acid residues, especially the RRE(9-11) motif, within the helical structure of the UL49.5 N-terminal fragment, as being crucial to the protein's activity. In this work, we investigated the effects of modifications within the RRE region on the spatial structure of the UL49.5 N-terminal fragment. The introduced RRE(9-11) variations were designed to abolish or stabilize the structure of the α-helix and, consequently, to increase or decrease protein activity compared to the wild type. The terminal structure of the peptides was established using circular dichroism (CD), 2D nuclear magnetic resonance (NMR), and molecular dynamics (MD) in membrane-mimetic or membrane-model environments. Our structural results show that in the RRE(9-11)AAA and E11G peptides the helical structure has been stabilized, whereas for the RRE(9-11)GGG peptide, as expected, the helix structure has partially unfolded compared to the native structure. These RRE modifications, in the context of the entire UL49.5 proteins, slightly altered their biological activity in human cells.


Assuntos
Infecções por Herpesviridae/virologia , Herpesvirus Bovino 1/química , Rinotraqueíte Infecciosa Bovina/virologia , Proteínas do Envelope Viral/química , Motivos de Aminoácidos , Animais , Bovinos , Humanos , Modelos Moleculares , Fragmentos de Peptídeos/química , Conformação Proteica , Estabilidade Proteica
3.
Molecules ; 25(3)2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-32013172

RESUMO

It is recognized that interactions between most materials are governed by their surface properties and manifest themselves at the interface formed between them. To gain more insight into this thin layer, several methods have been deployed. Among them, spectroscopic methods have been thoroughly evaluated. Due to their exceptional sensitivity, data acquisition speed, and broad material tolerance they have been proven to be invaluable tools for surface analysis, used by scientists in many fields, for example, implant studies. Today, in modern medicine the use of implants is considered standard practice. The past two decades of constant development has established the importance of implants in dentistry, orthopedics, as well as extended their applications to other areas such as aesthetic medicine. Fundamental to the success of implants is the knowledge of the biological processes involved in interactions between an implant and its host tissue, which are directly connected to the type of implant material and its surface properties. This review aims to demonstrate the broad applications of spectroscopic methods in implant material studies, particularly discussing hard implants, surface composition studies, and surface-cell interactions.


Assuntos
Materiais Biocompatíveis/análise , Próteses e Implantes , Análise Espectral , Humanos , Teste de Materiais , Ligas Metalo-Cerâmicas/análise , Ligas Metalo-Cerâmicas/química , Microscopia Eletrônica de Varredura , Análise Espectral/métodos , Aço/análise , Aço/química , Propriedades de Superfície , Titânio/análise , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...