Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Med Chem ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39018526

RESUMO

Acute respiratory viral infections, such as pneumovirus and respiratory picornavirus infections, exacerbate disease in COPD and asthma patients. A research program targeting respiratory syncytial virus (RSV) led to the discovery of GS-7682 (1), a novel phosphoramidate prodrug of a 4'-CN-4-aza-7,9-dideazaadenosine C-nucleoside GS-646089 (2) with broad antiviral activity against RSV (EC50 = 3-46 nM), human metapneumovirus (EC50 = 210 nM), human rhinovirus (EC50 = 54-61 nM), and enterovirus (EC50 = 83-90 nM). Prodrug optimization for cellular potency and lung cell metabolism identified 5'-methyl [(S)-hydroxy(phenoxy)phosphoryl]-l-alaninate in combination with 2',3'-diisobutyrate promoieties as being optimal for high levels of intracellular triphosphate formation in vitro and in vivo. 1 demonstrated significant reductions of viral loads in the lower respiratory tract of RSV-infected African green monkeys when administered once daily via intratracheal nebulized aerosol. Together, these findings support additional evaluation of 1 and its analogues as potential therapeutics for pneumo- and picornaviruses.

2.
Int J Mol Sci ; 25(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38612759

RESUMO

As a regulator of alveolo-capillary barrier integrity, Transient Receptor Potential Vanilloid 4 (TRPV4) antagonism represents a promising strategy for reducing pulmonary edema secondary to chemical inhalation. In an experimental model of acute lung injury induced by exposure of anesthetized swine to chlorine gas by mechanical ventilation, the dose-dependent effects of TRPV4 inhibitor GSK2798745 were evaluated. Pulmonary function and oxygenation were measured hourly; airway responsiveness, wet-to-dry lung weight ratios, airway inflammation, and histopathology were assessed 24 h post-exposure. Exposure to 240 parts per million (ppm) chlorine gas for ≥50 min resulted in acute lung injury characterized by sustained changes in the ratio of partial pressure of oxygen in arterial blood to the fraction of inspiratory oxygen concentration (PaO2/FiO2), oxygenation index, peak inspiratory pressure, dynamic lung compliance, and respiratory system resistance over 24 h. Chlorine exposure also heightened airway response to methacholine and increased wet-to-dry lung weight ratios at 24 h. Following 55-min chlorine gas exposure, GSK2798745 marginally improved PaO2/FiO2, but did not impact lung function, airway responsiveness, wet-to-dry lung weight ratios, airway inflammation, or histopathology. In summary, in this swine model of chlorine gas-induced acute lung injury, GSK2798745 did not demonstrate a clinically relevant improvement of key disease endpoints.


Assuntos
Lesão Pulmonar Aguda , Antineoplásicos , Benzimidazóis , Compostos de Espiro , Animais , Suínos , Cloro/toxicidade , Canais de Cátion TRPV , Lesão Pulmonar Aguda/induzido quimicamente , Lesão Pulmonar Aguda/tratamento farmacológico , Inflamação , Oxigênio
3.
Mol Pharm ; 21(1): 164-172, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38059771

RESUMO

In this article, we specify for the first time a quantitative biopharmaceutics classification system for orally inhaled drugs. To date, orally inhaled drug product developers have lacked a biopharmaceutics classification system like the one developed to navigate the development of immediate release of oral medicines. Guideposts for respiratory drug discovery chemists and inhalation product formulators have been elusive and difficult to identify due to the complexity of pulmonary physiology, the intricacies of drug deposition and disposition in the lungs, and the influence of the inhalation delivery device used to deliver the drug as a respirable aerosol. The development of an inhalation biopharmaceutics classification system (iBCS) was an initiative supported by the Product Quality Research Institute (PQRI). The goal of the PQRI iBCS working group was to generate a qualitative biopharmaceutics classification system that can be utilized by inhalation scientists as a "rule of thumb" to identify desirable molecular properties and recognize and manage CMC product development risks based on physicochemical properties of the drug and the deposited lung dose. Herein, we define the iBCS classes quantitatively according to the dose number and permeability. The proposed iBCS was evaluated for its ability to categorize marketed inhaled drugs using data from the literature. The appropriateness of the classification of each drug was assessed based on published development, clinical and nonclinical data, and mechanistic physiologically based biopharmaceutics modeling. The inhaled drug product development challenges for each iBCS classification are discussed and illustrated for different classes of marketed inhaled drugs. Finally, it is recognized that discriminatory laboratory methods to characterize regional lung deposition, dissolution, and permeability will be key to fully realizing the benefits of an iBCS to streamline and derisk inhaled drug development.


Assuntos
Biofarmácia , Nebulizadores e Vaporizadores , Biofarmácia/métodos , Solubilidade , Preparações Farmacêuticas , Administração por Inalação , Aerossóis/química , Permeabilidade
4.
Chest ; 165(3): 653-668, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37977263

RESUMO

BACKGROUND: Nebulizers are used commonly for inhaled drug delivery. Because they deliver medication through aerosol generation, clarification is needed on what constitutes safe aerosol delivery in infectious respiratory disease settings. The COVID-19 pandemic highlighted the importance of understanding the safety and potential risks of aerosol-generating procedures. However, evidence supporting the increased risk of disease transmission with nebulized treatments is inconclusive, and inconsistent guidelines and differing opinions have left uncertainty regarding their use. Many clinicians opt for alternative devices, but this practice could impact outcomes negatively, especially for patients who may not derive full treatment benefit from handheld inhalers. Therefore, it is prudent to develop strategies that can be used during nebulized treatment to minimize the emission of fugitive aerosols, these comprising bioaerosols exhaled by infected individuals and medical aerosols generated by the device that also may be contaminated. This is particularly relevant for patient care in the context of a highly transmissible virus. RESEARCH QUESTION: How can potential risks of infections during nebulization be mitigated? STUDY DESIGN AND METHODS: The COPD Foundation Nebulizer Consortium (CNC) was formed in 2020 to address uncertainties surrounding administration of nebulized medication. The CNC is an international, multidisciplinary collaboration of patient advocates, pulmonary physicians, critical care physicians, respiratory therapists, clinical scientists, and pharmacists from research centers, medical centers, professional societies, industry, and government agencies. The CNC developed this expert guidance to inform the safe use of nebulized therapies for patients and providers and to answer key questions surrounding medication delivery with nebulizers during pandemics or when exposure to common respiratory pathogens is anticipated. RESULTS: CNC members reviewed literature and guidelines regarding nebulization and developed two sets of guidance statements: one for the health care setting and one for the home environment. INTERPRETATION: Future studies need to explore the risk of disease transmission with fugitive aerosols associated with different nebulizer types in real patient care situations and to evaluate the effectiveness of mitigation strategies.


Assuntos
COVID-19 , Doença Pulmonar Obstrutiva Crônica , Humanos , Administração por Inalação , Pandemias/prevenção & controle , Aerossóis e Gotículas Respiratórios , Nebulizadores e Vaporizadores , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Broncodilatadores
5.
Microbiol Spectr ; 11(6): e0471722, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37882564

RESUMO

IMPORTANCE: The main route of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission is airborne. However, there are few experimental systems that can assess the airborne transmission dynamics of SARS-CoV-2 in vivo. Here, we designed, built, and characterized a hamster transmission caging and exposure system that allows for efficient SARS-CoV-2 airborne transmission in Syrian hamsters without contributions from fomite or direct contact transmission. We successfully measured SARS-CoV-2 viral RNA in aerosols and demonstrated that SARS-CoV-2 is transmitted efficiently at either a 1:1 or 1:4 infected index to naïve recipient hamster ratio. This is meaningful as a 1:4 infected index to naïve hamster ratio would allow for simultaneous comparisons of various interventions in naïve animals to determine their susceptibility to infection by aerosol transmission of SARS-CoV-2. Our SARS-CoV-2 exposure system allows for testing viral airborne transmission dynamics and transmission-blocking therapeutic strategies against SARS-CoV-2 in Syrian hamsters.


Assuntos
COVID-19 , SARS-CoV-2 , Cricetinae , Animais , Mesocricetus , Aerossóis e Gotículas Respiratórios , Modelos Animais de Doenças
6.
Expert Opin Drug Deliv ; 20(8): 1097-1113, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37732957

RESUMO

INTRODUCTION: Inhaled gene therapy programs targeting diseases of the lung have seen increasing interest in recent years, though as of yet no product has successfully entered the market. Preclinical research to support such programs is critically important in maximizing the chances of developing successful candidates. AREAS COVERED: Aspects of inhalation delivery of gene therapies are reviewed, with a focus on preclinical research in animal models. Various barriers to inhalation delivery of gene therapies are discussed, including aerosolization stresses, aerosol behavior in the respiratory tract, and disposition processes post-deposition. Important aspects of animal models are considered, including determinations of biologically relevant determinations of dose and issues related to translatability. EXPERT OPINION: Development of clinically-efficacious inhaled gene therapies has proven difficult owing to numerous challenges. Fit-for-purpose experimental and analytical methods are necessary for determinations of biologically relevant doses in preclinical animal models. Further developments in disease-specific animal models may aid in improving the translatability of results in future work, and we expect to see accelerated interests in inhalation gene therapies for various diseases. Sponsors, researchers, and regulators are encouraged to engage in early and frequent discussion regarding candidate therapies, and additional dissemination of preclinical methodologies would be of immense value in avoiding common pitfalls.


Assuntos
Desenvolvimento de Medicamentos , Pulmão , Animais , Administração por Inalação , Aerossóis , Modelos Animais , Sistemas de Liberação de Medicamentos
7.
J Pharmacol Toxicol Methods ; 122: 107271, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37196729

RESUMO

INTRODUCTION: 1,1-Difluoroethane (HFA-152a) is being developed as an alternative propellant in pressurized metered dose inhalers (pMDIs). As a part of the regulatory development pathway, pharmacology, toxicology and clinical studies have been conducted with inhaled HFA-152a. These studies require fit for purpose regulatory compliant (GxP validated) methods for quantification of HFA-152a from blood. METHODS: As HFA-152a is a gas at standard temperature and pressure, novel methods were developed to support the analysis across the wide range of species and concentrations required for regulatory filing. RESULTS: The developed methods utilized a headspace auto sampler coupled to a gas chromatograph (GC) with flame ionization detection. Key factors in the successful method included bringing together fit for purpose approaches to the head space vials, volume of matrix (blood), detection range required for species/study objective, handling / transfer of blood into head space vials and the stability/storage required for the analysis of the samples. The species-specific assays were fully validated under regulatory (GLP) conditions for mouse, rat, rabbit, canine and human and non-regulatory (non GLP) validations for guinea pig and cell culture media. DISCUSSION: Overall the novel approach of head space analysis of whole blood allowed for the development and validation of assays used to generate the toxicokinetic data that supported clinical testing of HFA-152a as a new pMDI propellant.


Assuntos
Propelentes de Aerossol , Hidrocarbonetos Fluorados , Humanos , Animais , Cães , Cobaias , Camundongos , Coelhos , Ratos , Inaladores Dosimetrados , Técnicas de Cultura de Células
8.
Inhal Toxicol ; 35(5-6): 169-174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37159420

RESUMO

OBJECTIVE: Availability and consumer use of hemp products is rapidly increasing, but little work has been done to assess aerosol emissions of hemp pre-rolls. The objective of this research was to characterize the aerosol of pre-rolled joints from hemp material enriched for production of cannabigerol (CBG) that were smoked on a test system mimicking human use patterns. MATERIALS AND METHODS: Aerosol emissions were collected and analyzed using glass microfiber filters and charcoal cartridges. The aerosol was screened for nine phytocannabinoids and 19 terpenes. RESULTS: Three phytocannabinoids (CBG, cannabichromene (CBC), and delta-9-tetrahydrocannabinol (THC)) were detected and quantified at a mean (SD) concentration of 19.4 (4.7), 0.48 (0.01), and 0.40 (0.04) mg per pre-roll, respectively. Five terpenes ((-)-α-bisabolol, (-)-guaiol, ß-caryophyllene, nerolidol, and α-humulene) were detected and quantified at an average concentration of 352.7 (112.0), 194.3 (66.4), 106.0 (50.4), 28.3 (9.3), and 27.7 (11.2) µg per pre-roll, respectively. Particle size distribution testing via aerodynamic particle sizer and inertial impactor showed that average size of emitted aerosols was 0.77 (0.0) and 0.54 (0.1) µm, respectively. CONCLUSIONS: This study describes methodology for characterization of cannabinoid and terpene dose in emitted aerosols and aerosolization efficiency from hemp pre-rolls. It also presents these data for one of the marketed products.


Assuntos
Cannabis , Humanos , Aerossóis , Fumaça
9.
Inhal Toxicol ; 34(11-12): 319-328, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35913821

RESUMO

Aim: The cardiovascular toxicity of unheated and heated flavorants and their products as commonly present in electronic cigarette liquids (e-liquids) was evaluated previously in vitro. Based on the results of in vitro assays, cinnamaldehyde, eugenol, menthol, and vanillin were selected to conduct a detailed chemical analysis of the aerosol generated following heating of each compound both at 250 and 750 °C. Materials and Methods: Each flavoring was heated in a drop-tube furnace within a quartz tube. The combustion atmosphere was captured using different methods to enable analysis of 308 formed compounds. Volatile organic compounds (VOCs) were captured with an evacuated Summa canister and assayed via gas chromatography interfaced with mass spectrometry (GC-MS). Carbonyls (aldehydes and ketones) were captured using a 2,4-dinitrophenylhydrazine (DNPH) cartridge and assayed via a high-performance liquid chromatography-ultra-violet (HPLC-UV) assay. Polyaromatic hydrocarbons (PAHs) were captured using an XAD cartridge and filter, and extracts were assayed using GC-MS/MS. Polar compounds were assayed after derivatization of the XAD/filter extracts and analyzed via GC-MS. Conclusion: At higher temperature, both cinnamaldehyde and menthol combustion significantly increased formaldehyde and acetaldehyde levels. At higher temperature, cinnamaldehyde, eugenol, and menthol resulted in increased benzene concentrations. At low temperature, all four compounds led to higher levels of benzoic acid. These data show that products of thermal degradation of common flavorant compounds vary by flavorant and by temperature and include a wide variety of harmful and potentially harmful constituents (HPHCs).


Assuntos
Aerossóis , Sistemas Eletrônicos de Liberação de Nicotina , Aromatizantes , Temperatura Alta , Produtos do Tabaco , Acetaldeído/análise , Acroleína/análise , Aerossóis/química , Benzeno/análise , Ácido Benzoico/análise , Eugenol/análise , Formaldeído/análise , Cetonas/análise , Mentol/análise , Espectrometria de Massas em Tandem , Produtos do Tabaco/análise , Compostos Orgânicos Voláteis/análise , Aromatizantes/química
10.
Mol Pharm ; 19(7): 2032-2039, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35576168

RESUMO

For oral drugs, the formulator and discovery chemist have a tool available to them that can be used to navigate the risks associated with the selection and development of immediate release oral drugs and drug products. This tool is the biopharmaceutics classification system (giBCS). Unfortunately, no such classification system exists for inhaled drugs. The perspective outlined in this manuscript provides the foundational principles and framework for a classification system for inhaled drugs. The proposed classification system, an inhalation-based biopharmaceutics classification system (iBCS), is based on fundamental biopharmaceutics principles adapted to an inhalation route of administration framework. It is envisioned that a classification system for orally inhaled drugs will facilitate an understanding of the technical challenges associated with the development of new chemical entities and their associated new drug products (device and drug formulation combinations). Similar to the giBCS, the iBCS will be based on key attributes describing the drug substance (solubility and permeability) and the drug product (dose and dissolution). This manuscript provides the foundational aspects of an iBCS, including the proposed scientific principles and framework upon which such a system can be developed.


Assuntos
Biofarmácia , Administração por Inalação , Administração Oral , Permeabilidade , Preparações Farmacêuticas , Solubilidade
11.
Sci Transl Med ; 14(658): eabn6868, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35511920

RESUMO

Transmission-blocking strategies that slow the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and protect against coronavirus disease 2019 (COVID-19) are needed. We have developed an orally delivered adenovirus type 5-vectored SARS-CoV-2 vaccine candidate that expresses the spike protein. Here, we demonstrated that hamsters vaccinated by the oral or intranasal route had robust and cross-reactive antibody responses. We then induced a postvaccination infection by inoculating vaccinated hamsters with SARS-CoV-2. Orally or intranasally vaccinated hamsters had decreased viral RNA and infectious virus in the nose and lungs and experienced less lung pathology compared to mock-vaccinated hamsters after SARS-CoV-2 challenge. Naïve hamsters exposed in a unidirectional air flow chamber to mucosally vaccinated, SARS-CoV-2-infected hamsters also had lower nasal swab viral RNA and exhibited fewer clinical symptoms than control animals, suggesting that the mucosal route reduced viral transmission. The same platform encoding the SARS-CoV-2 spike and nucleocapsid proteins elicited mucosal cross-reactive SARS-CoV-2-specific IgA responses in a phase 1 clinical trial (NCT04563702). Our data demonstrate that mucosal immunization is a viable strategy to decrease SARS-CoV-2 disease and airborne transmission.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Adenoviridae , Animais , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/prevenção & controle , Ensaios Clínicos Fase I como Assunto , Cricetinae , Humanos , RNA Viral , SARS-CoV-2 , Índice de Gravidade de Doença
12.
Mol Pharm ; 19(7): 2040-2047, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35609877

RESUMO

This work is the second in a series of publications outlining the fundamental principles and proposed design of a biopharmaceutics classifications system for inhaled drugs and drug products (the iBCS). Here, a mechanistic computer-based model has been used to explore the sensitivity of the primary biopharmaceutics functional output parameters: (i) pulmonary fraction dose absorbed (Fabs) and (ii) drug half-life in lumen (t1/2) to biopharmaceutics-relevant input attributes including dose number (Do) and effective permeability (Peff). Results show the nonlinear sensitivity of primary functional outputs to variations in these attributes. Drugs with Do < 1 and Peff > 1 × 10-6 cm/s show rapid (t1/2 < 20 min) and complete (Fabs > 85%) absorption from lung lumen into lung tissue. At Do > 1, dissolution becomes a critical drug product attribute and Fabs becomes dependent on regional lung deposition. The input attributes used here, Do and Peff, thus enabled the classification of inhaled drugs into parameter spaces with distinctly different biopharmaceutic risks. The implications of these findings with respect to the design of an inhalation-based biopharmaceutics classification system (iBCS) and to the need for experimental methodologies to classify drugs need to be further explored.


Assuntos
Biofarmácia , Absorção Intestinal , Biofarmácia/métodos , Pulmão , Modelos Biológicos , Permeabilidade , Solubilidade
13.
J Aerosol Med Pulm Drug Deliv ; 35(1): 50-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34619040

RESUMO

Background: Bacillus Calmette-Guérin (BCG) is a vaccine used to protect against tuberculosis primarily in infants to stop early infection in areas of the world where the disease is endemic. Normally administered as a percutaneous injection, BCG is a live significantly attenuated bacteria that is now being investigated for its potential within an inhalable vaccine formulation. This study investigates the feasibility and performance of two jet and two vibrating mesh nebulizers aerosolizing BCG and the resulting particle characteristics and residual viability of the bacteria postaerosolization. Methods: A jet nebulizer (Collison), outfitted either with a 3- or 6-jet head, was compared with two clinical nebulizers, the vibrating mesh Omron MicroAir and Aerogen Solo devices. Particle characteristics, including aerodynamic particle sizing, was performed on all devices within a common aerosol chamber configuration and comparable BCG innocula concentrations. Integrated aerosol samples were collected for each generator and assayed for bacterial viability using conventional microbiological technique. Results: A batch lot of BCG (Danish) was grown to titer and used in all generator assessments. Aerosol particles within the respirable range were generated from all nebulizers at four different concentrations of BCG. The jet nebulizers produced a uniformly smaller particle size than the vibrating mesh devices, although particle concentrations by mass were similar across all devices tested with the exception of the Aerogen Solo, which resulted in a low concentration of BCG aerosols. Conclusions: The resulting measured viable BCG aerosol concentration fraction produced by each device approximated one another; however, a measurable decrease of efficiency and overall viability reduction in the jet nebulizer was observed in higher BCG inoculum starting concentrations, whereas the vibrating mesh nebulizer returned a remarkably stable viable aerosol fraction irrespective of inoculum concentration.


Assuntos
Vacina BCG , Telas Cirúrgicas , Administração por Inalação , Aerossóis , Albuterol , Broncodilatadores , Sistemas de Liberação de Medicamentos , Desenho de Equipamento , Humanos , Nebulizadores e Vaporizadores , Tamanho da Partícula
14.
Sci Transl Med ; 14(633): eabl8282, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-34968150

RESUMO

Remdesivir (RDV) is a nucleotide analog prodrug with demonstrated clinical benefit in patients with coronavirus disease 2019 (COVID-19). In October 2020, the US FDA approved intravenous (IV) RDV as the first treatment for hospitalized COVID-19 patients. Furthermore, RDV has been approved or authorized for emergency use in more than 50 countries. To make RDV more convenient for non-hospitalized patients earlier in disease, alternative routes of administration are being evaluated. Here, we investigated the pharmacokinetics and efficacy of RDV administered by head dome inhalation in African green monkeys (AGM). Relative to an IV administration of RDV at 10 mg/kg, an approximately 20-fold lower dose administered by inhalation produced comparable concentrations of the pharmacologically active triphosphate in lower respiratory tract tissues. Distribution of the active triphosphate into the upper respiratory tract was also observed following inhaled RDV exposure. Inhalation RDV dosing resulted in lower systemic exposures to RDV and its metabolites as compared with IV RDV dosing. An efficacy study with repeated dosing of inhaled RDV in an AGM model of SARS-CoV-2 infection demonstrated reductions in viral replication in bronchoalveolar lavage fluid and respiratory tract tissues compared with placebo. Efficacy was observed with inhaled RDV administered once daily at a pulmonary deposited dose of 0.35 mg/kg beginning approximately 8 hours post-infection. Moreover, the efficacy of inhaled RDV was similar to that of IV RDV administered once at 10 mg/kg followed by 5 mg/kg daily in the same study. Together, these findings support further clinical development of inhalation RDV.


Assuntos
Tratamento Farmacológico da COVID-19 , Monofosfato de Adenosina/análogos & derivados , Alanina/análogos & derivados , Animais , Antivirais/farmacocinética , Chlorocebus aethiops , Humanos , Primatas , SARS-CoV-2 , Carga Viral
15.
AAPS PharmSciTech ; 22(7): 230, 2021 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-34467438

RESUMO

Local delivery of biotherapeutics to the lung holds great promise for treatment of lung diseases, but development of physically stable, biologically active dry powder formulations of large molecules for inhalation has remained a challenge. Here, spray drying was used to manufacture a dry powder pulmonary formulation of bevacizumab, a monoclonal antibody approved to treat non-small cell lung cancer (NSCLC) by intravenous infusion. By reformulating bevacizumab for local delivery, reduced side effects, lower doses, and improved patient compliance are possible. The formulation had aerosol properties suitable for delivery to the deep lung, as well as good physical stability at ambient temperature for at least 6 months. Bevacizumab's anti-VEGF bioactivity was not impacted by the manufacturing process. The formulation was efficacious in an in vivo rat model for NSCLC at a 10-fold decrease in dose relative to the intravenous control.


Assuntos
Antineoplásicos Imunológicos , Bevacizumab , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Administração por Inalação , Aerossóis , Animais , Antineoplásicos Imunológicos/administração & dosagem , Bevacizumab/administração & dosagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Inaladores de Pó Seco , Neoplasias Pulmonares/tratamento farmacológico , Tamanho da Partícula , Pós , Ratos
16.
Drug Deliv ; 28(1): 767-775, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33860729

RESUMO

Topotecan is potent anti-cancer drug approved for various malignancies but hematopoietic toxicities undermine its wider application and use of its most effective dose. This study aims to improve these limitations through inhalation-delivery. The pharmacokinetics, efficacy, and toxicity of 2-5 times lower inhalation doses of topotecan dry-powder were compared with the standard intravenous (IV) delivery once/twice-a-week. Human-derived EGFR-mutant (H1975), KRAS-mutant (A549), and EGFR/KRAS wild-type (H358) orthotopic and distant lung tumors were evaluated in murine models. Inhalation of 1 mg/kg topotecan significantly improved the half-life and drug exposure (area under the curve, AUC) compared to 5 mg/kg via IV-delivery. AUCs (h*ng/mL) for inhaled/IV topotecan in plasma, lung, liver, and brain were, 831/888, 60,000/1080, 8380/4000, and 297/15, respectively; while the half-life was also greatly increased in these tissues. The average lung tumor burden of H358-derived tumors was reduced from 15.0 g to 8.4 g (44%) in rats treated once-a-week with 2 mg/kg IV and 1.8 g (88%) with 1 mg/kg inhaled topotecan, corroborating previous findings using A549- and H1975-derived orthotopic lung tumors. Importantly, inhaled topotecan showed superior efficacy in suppressing lung tumors at distant sites. The growth of H1975- and H358-derived subcutaneous xenografts were completely arrested and A549-derived tumors were significantly reduced in mice treated twice-a-week with 1 mg/kg inhaled topotecan compared to a minor (H1975 and H358) or no reduction (A549) with twice-a-week 5 mg/kg IV topotecan.


Assuntos
Neoplasias Pulmonares/tratamento farmacológico , Inibidores da Topoisomerase I/farmacologia , Topotecan/farmacologia , Administração por Inalação , Animais , Protocolos de Quimioterapia Combinada Antineoplásica , Linhagem Celular Tumoral , Química Farmacêutica , Genes erbB-1/genética , Meia-Vida , Humanos , Taxa de Depuração Metabólica , Proteínas Proto-Oncogênicas p21(ras)/genética , Ratos , Ratos Sprague-Dawley , Inibidores da Topoisomerase I/administração & dosagem , Inibidores da Topoisomerase I/farmacocinética , Topotecan/administração & dosagem , Topotecan/farmacocinética , Carga Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Front Pharmacol ; 12: 799034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35126135

RESUMO

Converting a vaccine into a thermostable dry powder is advantageous as it reduces the resource burden linked with the cold chain and provides flexibility in dosage and administration through different routes. Such a dry powder presentation may be especially useful in the development of a vaccine towards the respiratory infectious disease tuberculosis (TB). This study assesses the immunogenicity and protective efficacy of spray-dried ID93+GLA-SE, a promising TB vaccine candidate, against Mycobacterium tuberculosis (Mtb) in a murine model when administered via different routes. Four administration routes for the spray-dried ID93+GLA-SE were evaluated along with relevant controls-1) reconstitution and intramuscular injection, 2) reconstitution and intranasal delivery, 3) nasal dry powder delivery via inhalation, and 4) pulmonary dry powder delivery via inhalation. Dry powder intranasal and pulmonary delivery was achieved using a custom nose-only inhalation device, and optimization using representative vaccine-free powder demonstrated that approximately 10 and 44% of the maximum possible delivered dose would be delivered for intranasal delivery and pulmonary delivery, respectively. Spray-dried powder was engineered according to the different administration routes including maintaining approximately equivalent delivered doses of ID93 and GLA. Vaccine properties of the different spray-dried lots were assessed for quality control in terms of nanoemulsion droplet diameter, polydispersity index, adjuvant content, and antigen content. Our results using the Mtb mouse challenge model show that both intranasal reconstituted vaccine delivery as well as pulmonary dry powder vaccine delivery resulted in Mtb control in infected mice comparable to traditional intramuscular delivery. Improved protection in these two vaccinated groups over their respective control groups coincided with the presence of cytokine-producing T cell responses. In summary, our results provide novel vaccine formulations and delivery routes that can be harnessed to provide protection against Mtb infection.

18.
J Aerosol Med Pulm Drug Deliv ; 33(6): 300-304, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32783675

RESUMO

National and international guidelines recommend droplet/airborne transmission and contact precautions for those caring for coronavirus disease 2019 (COVID-19) patients in ambulatory and acute care settings. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus, an acute respiratory infectious agent, is primarily transmitted between people through respiratory droplets and contact routes. A recognized key to transmission of COVID-19, and droplet infections generally, is the dispersion of bioaerosols from the patient. Increased risk of transmission has been associated with aerosol generating procedures that include endotracheal intubation, bronchoscopy, open suctioning, administration of nebulized treatment, manual ventilation before intubation, turning the patient to the prone position, disconnecting the patient from the ventilator, noninvasive positive-pressure ventilation, tracheostomy, and cardiopulmonary resuscitation. The knowledge that COVID-19 subjects can be asymptomatic and still shed virus, producing infectious droplets during breathing, suggests that health care workers (HCWs) should assume every patient is potentially infectious during this pandemic. Taking actions to reduce risk of transmission to HCWs is, therefore, a vital consideration for safe delivery of all medical aerosols. Guidelines for use of personal protective equipment (glove, gowns, masks, shield, and/or powered air purifying respiratory) during high-risk procedures are essential and should be considered for use with lower risk procedures such as administration of uncontaminated medical aerosols. Bioaerosols generated by infected patients are a major source of transmission for SARS CoV-2, and other infectious agents. In contrast, therapeutic aerosols do not add to the risk of disease transmission unless contaminated by patients or HCWs.


Assuntos
COVID-19/prevenção & controle , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Exposição por Inalação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Aerossóis , COVID-19/transmissão , Humanos , Exposição por Inalação/efeitos adversos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Medição de Risco , Fatores de Risco
19.
Br J Cancer ; 122(8): 1194-1204, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32103148

RESUMO

BACKGROUND: Epigenetic therapy through demethylation of 5-methylcytosine has been largely ineffective in treating lung cancer, most likely due to poor tissue distribution with oral or subcutaneous delivery of drugs such as 5-azacytidine (5AZA). An inhalable, stable dry powder formulation of 5AZA was developed. METHODS: Pharmacokinetics of inhaled dry powder and aqueous formulations of 5AZA were compared to an injected formulation. Efficacy studies and effect of therapy on the epigenome were conducted in an orthotopic rat lung cancer model for inhaled formulations. RESULTS: Inhaled dry powder 5AZA showed superior pharmacokinetic properties in lung, liver, brain and blood compared to the injected formulation and for all tissues except lung compared to an inhaled aqueous formulation. Only dry powder 5AZA was detected in brain (~4-h half-life). Inhaled dry powder was superior to inhaled aqueous 5AZA in reducing tumour burden 70-95%. Superiority of inhaled 5AZA dry powder was linked to effectively reprogramming the cancer genome through demethylation and gene expression changes in cancer signalling and immune pathways. CONCLUSIONS: These findings could lead to widespread use of this drug as the first inhaled dry powder therapeutic for treating local and metastatic lung cancer, for adjuvant therapy, and in combination with immunotherapy to improve patient survival.


Assuntos
Azacitidina/administração & dosagem , Neoplasias Pulmonares/tratamento farmacológico , Administração por Inalação , Animais , Antígenos de Neoplasias/análise , Azacitidina/farmacocinética , Desmetilação , Composição de Medicamentos , Epigenoma , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Masculino , Pós , Ratos , Ratos Sprague-Dawley , Ensaios Antitumorais Modelo de Xenoenxerto
20.
J Aerosol Med Pulm Drug Deliv ; 33(1): 21-33, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31436493

RESUMO

Background: Lucinactant for inhalation is an investigational noninvasive, aerosolized surfactant replacement therapy for treatment of preterm neonates with respiratory distress syndrome. Lucinactant for inhalation consists of lyophilized lucinactant and the Aerosurf® Delivery System (ADS). The objective of this study was to characterize the total and regional pulmonary deposition of lucinactant delivered by the ADS in nonhuman primates (NHPs). Methods: Lucinactant was radiolabeled by the addition of technetium-99m (99mTc)-sulfur colloid. The radiolabeled aerosol was characterized and validated using a Mercer cascade impactor. An in vivo deposition study was performed in three cynomolgus macaques. Radiolabeled lucinactant was aerosolized using the ADS and delivered via nasal cannula under 5 cm H2O nasal continuous positive airway pressure (nCPAP) for 5-9 minutes. A two-dimensional planar image was acquired immediately after aerosol administration, followed by a three-dimensional single-photon emission computed tomography (SPECT) image and a second planar image. The images were analyzed to determine the pulmonary (lungs) and extrapulmonary (nose + mouth, trachea, stomach) distribution. The SPECT data were used to determine regional deposition. Results: The radiolabed lucinactant aerosol had a mass median aerodynamic diameter = 2.91 µm, geometric standard deviation (GSD) = 1.81, and an activity median aerodynamic diameter = 2.92 µm, GSD = 2.06. Aerosolized lucinactant was observed to deposit in the lungs (11.4%), nose + mouth (79.9%), trachea (7.3%), and stomach (1.4%). Analysis of the SPECT image demonstrated that the regional deposition within the lung was generally homogeneous. Aerosolized lucinactant was deposited in both the central (52.8% ± 1.2%) and peripheral (47.2% ± 1.2%) regions of the lungs. Conclusion: Aerosolized lucinactant, delivered using the ADS via constant flow nCPAP, is deposited in all regions of the lungs demonstrating that surfactant can be aerosolized and delivered noninvasively to NHPs.


Assuntos
Sistemas de Liberação de Medicamentos , Álcoois Graxos/administração & dosagem , Pulmão/metabolismo , Fosfatidilgliceróis/administração & dosagem , Proteínas/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Administração por Inalação , Aerossóis , Animais , Combinação de Medicamentos , Álcoois Graxos/farmacocinética , Humanos , Macaca fascicularis , Fosfatidilgliceróis/farmacocinética , Proteínas/farmacocinética , Surfactantes Pulmonares/farmacocinética , Tecnécio , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...