Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dokl Biochem Biophys ; 484(1): 48-51, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31012012

RESUMO

To select the optimum method for disinfecting scaffolds before recellularization, the effects of octenisept and chlorhexidine at different concentrations on lung biological matrices before and after decellularization were studied by using morphological methods (studies of biomechanical strength of extracellular matrix fibers) and by analyzing chemiluminescence in rats. Chlorhexidine diluted 1 : 10 had the least damage on the matrix properties and to the greatest extent contributed to disinfection of scaffolds for their further storage and experimental studies.


Assuntos
Anti-Infecciosos Locais/química , Clorexidina/química , Desinfecção/métodos , Matriz Extracelular/química , Pulmão/química , Animais , Ratos
2.
Dokl Biochem Biophys ; 484(1): 82-84, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31012021

RESUMO

It was found that the chemiluminescence intensity in native and recellularized tissues of rat muscular organs as well as in their decellularized scaffolds can serve as an express criterion that, along with ultrastructural analysis, makes it possible to perform quantitative assessment of the viability of cellular structures in biological samples of the diaphragm.


Assuntos
Diafragma/química , Medições Luminescentes , Engenharia Tecidual , Alicerces Teciduais/química , Animais , Ratos
3.
Bull Exp Biol Med ; 166(2): 287-292, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30488196

RESUMO

Based on the data of morphological analysis, we performed histological evaluation of rat tissue reaction to subcutaneous implantation of decellularized matrices of intrathoracic organs and tissues. Cell composition of the inflammatory infiltrate was analyzed, and the dynamics of macrophage and T and B lymphocyte content was assessed on days 7 and 14 of the experiment. It was found that the reaction to implantation depended not only on the quality of decellularization and efficiency of removal of antigen molecules, but also on the original histological structure and quality of preimplantation processing of the transplant.


Assuntos
Diafragma/ultraestrutura , Matriz Extracelular/ultraestrutura , Pulmão/ultraestrutura , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Antígenos CD/imunologia , Antígenos CD/metabolismo , Linfócitos B/citologia , Linfócitos B/imunologia , Biomarcadores/metabolismo , Ácido Desoxicólico/química , Ácido Desoxicólico/farmacologia , Desoxirribonucleases/química , Desoxirribonucleases/farmacologia , Diafragma/citologia , Diafragma/efeitos dos fármacos , Diafragma/transplante , Matriz Extracelular/química , Coração/efeitos dos fármacos , Lectinas Tipo C/imunologia , Lectinas Tipo C/metabolismo , Pulmão/citologia , Pulmão/efeitos dos fármacos , Macrófagos/citologia , Macrófagos/imunologia , Masculino , Receptor de Manose , Lectinas de Ligação a Manose/imunologia , Lectinas de Ligação a Manose/metabolismo , Ratos , Ratos Wistar , Receptores de Superfície Celular/imunologia , Receptores de Superfície Celular/metabolismo , Pele , Linfócitos T/citologia , Linfócitos T/imunologia , Transplante Homólogo
4.
Bull Exp Biol Med ; 164(6): 770-774, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29658077

RESUMO

Biological compatibility of a tissue engineered construct of the trachea (synthetic scaffold) and allogenic mesenchymal stem cells was studied on laboratory Papio hamadryas primates. Subcutaneous implantation and orthotopic transplantations of tissue engineered constructs were carried out. Histological studies of the construct showed chaotically located filaments and mononuclear cells fixed to them. Development of a fine connective tissue capsule was found at the site of subcutaneous implantation of the tissue engineered construct. The intact structure of the scaffold populated by various cell types in orthotopic specimens was confirmed by expression of specific proteins. The results indicated biological compatibility of the tissue engineered construct with the mesenchymal stem cells; no tissue rejection reactions were recorded; simulation of respiratory disease therapy on Papio hamadryas proved to be an adequate model.


Assuntos
Corpos Estranhos/cirurgia , Transplante de Células-Tronco Mesenquimais , Polietilenotereftalatos/farmacologia , Engenharia Tecidual/métodos , Alicerces Teciduais , Traqueia/transplante , Animais , Biomarcadores/metabolismo , Adesão Celular/efeitos dos fármacos , Expressão Gênica , Queratinas/genética , Queratinas/metabolismo , Lectinas Tipo C/genética , Lectinas Tipo C/metabolismo , Leucócitos Mononucleares/citologia , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/metabolismo , Masculino , Receptor de Manose , Lectinas de Ligação a Manose/genética , Lectinas de Ligação a Manose/metabolismo , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Papio hamadryas , Receptores de Superfície Celular/genética , Receptores de Superfície Celular/metabolismo , Tela Subcutânea/cirurgia , Transplante Autólogo , Vimentina/genética , Vimentina/metabolismo
5.
Arkh Patol ; 79(5): 49-56, 2017.
Artigo em Russo | MEDLINE | ID: mdl-29027530

RESUMO

Automated image analysis methods are highly important for biotechnology research. The authors developed and tested a program for the morphometric analysis of photomicrographs of the sections processed using the standard immunohistochemical examination protocols. The color deconvolution method used in the algorithm was proven to be effective in mapping the distribution of DAB chromogen in the sample containing multiple dyes. The experiment demonstrated that the level of extracellular matrix proteins could be comparatively quantified in different groups of samples. The effective methods for the quantitative analysis of the Ki-67 labelling index were also tested using the same algorithms. The developed program was published under free GPL 3.0.


Assuntos
Antígenos Nucleares/isolamento & purificação , Matriz Extracelular/ultraestrutura , Processamento de Imagem Assistida por Computador/métodos , Imuno-Histoquímica/métodos , Algoritmos , Antígenos Nucleares/ultraestrutura , Corantes/química , Corantes/isolamento & purificação , Humanos , Software
6.
Urologiia ; (2): 5-13, 2017 Jun.
Artigo em Russo | MEDLINE | ID: mdl-28631900

RESUMO

Chronic renal failure (CRF) is one of the most challenging problems of contemporary medicine. Patients with chronic renal failure usually need renal replacement therapy as either hemodialysis, peritoneal dialysis or a kidney transplant. The latter is the most promising option for end-stage kidney disease. However, the shortage of donor organs, the complexity of their delivery, the difficulty in finding an immunologically compatible donor and the need for lifelong immunosuppression triggered advances in modern tissue engineering. In this field, the primary priority is focused on developing bioengineered scaffolds with subsequent recellularization with autologous cells. Using such constructs would allow for solving both ethical and immunological problems of transplantation. The aim of this pilot study was to develop a new method of renal decellularization using small laboratory animals. MATERIALS AND METHODS: The study investigated the morphological structure of the obtained decellularized matrix and quantitatively tested DNA residues in the resulting scaffold. We proposed a new biophysical method for assessing the matrix quality using the EPR spectroscopy and conducted experiments on the matrix recellularization with mesenchymal multipotent stem cells to estimate cytotoxicity, cell viability and metabolic activity. RESULTS: The obtained decellularized renal matrix retained the native tissue architecture after a complete removal of the cell material, had no cytotoxic properties and supported cell adhesion and proliferation. CONCLUSION: All the above suggests that the proposed decellularization protocol is a promising method to produce tissue-engineered kidney constructs with possible clinical application in the foreseeable future.


Assuntos
Falência Renal Crônica/terapia , Rim/anatomia & histologia , Rins Artificiais , Engenharia Tecidual , Alicerces Teciduais , Animais , Separação Celular , Rim/citologia , Ratos
7.
Bull Exp Biol Med ; 162(5): 703-706, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28361431

RESUMO

We modified the protocol of obtaining of biological scaffolds of rat lungs based on dynamic recording of specific resistivity of working detergent solution (conductometry) during perfusion decellularization. Termination of sodium deoxycholate exposure after attaining ionic equilibrium plateau did not impair the quality of decellularization and preserved structural matrix components, which was confirmed by morphological analysis and quantitative assay of residual DNA.


Assuntos
Pulmão , Alicerces Teciduais , Animais , Condutometria , Ácido Desoxicólico/química , Detergentes/química , Condutividade Elétrica , Pulmão/citologia , Masculino , Ratos Wistar , Soluções , Engenharia Tecidual , Fixação de Tecidos
8.
Dokl Biochem Biophys ; 470(1): 375-378, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27817028

RESUMO

The effect of decellularization on the biomechanical properties of macaque lungs was studied. The quality of the biological scaffold was additionally assessed by morphological methods, and the contents of extracellular matrix (ECM) fibers were determined both qualitatively and quantitatively. Histological analysis revealed no damage of structural integrity of ECM components, but the scaffold elasticity significantly decreased, which was confirmed by the changes in the hysteresis loop without a concomitant decrease in peak loads, with the mechanical strength of the samples being retained. These changes require taking additional measures to prevent a decrease in the effective lung volume.


Assuntos
Matriz Extracelular/metabolismo , Pulmão/fisiologia , Engenharia Tecidual , Animais , Fenômenos Biomecânicos , Elasticidade , Macaca mulatta , Masculino , Engenharia Tecidual/métodos , Alicerces Teciduais
9.
Dokl Biochem Biophys ; 467(1): 113-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27193712

RESUMO

Using EPR spectroscopy it was established that the determination of the concentration of paramagnetic centers in lyophilized tissues allows indirect evaluation of the quality of decellularization of intrathoracic organs (diaphragm, heart, and lungs), since the content of paramagnetic particles in them can serve as a criterion of cell viability and points to the necessity to repeat decellularization. Experiments in rats showed that the EPR spectra of the native thoracic organs contained paramagnetic centers with g-factor values ranging from 2.007 to 2.011 at a concentration of 10(-8) to 6.62 × 10(-7) mol/g of lyophilized tissue, whereas in all decellularized tissues of the same organs paramagnetic particles were not detected.


Assuntos
Diafragma/química , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Pulmão/química , Miocárdio/química , Engenharia Tecidual , Animais , Animais não Endogâmicos , Benzoquinonas/análise , Liofilização , Masculino , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...