1.
J Clin Sleep Med ; 20(1): 121-125, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37904574

RESUMO

The period of the year from spring to fall, when clocks in most parts of the United States are set one hour ahead of standard time, is called daylight saving time, and its beginning and ending dates and times are set by federal law. The human biological clock is regulated by the timing of light and darkness, which then dictates sleep and wake rhythms. In daily life, the timing of exposure to light is generally linked to the social clock. When the solar clock is misaligned with the social clock, desynchronization occurs between the internal circadian rhythm and the social clock. The yearly change between standard time and daylight saving time introduces this misalignment, which has been associated with risks to physical and mental health and safety, as well as risks to public health. In 2020, the American Academy of Sleep Medicine (AASM) published a position statement advocating for the elimination of seasonal time changes, suggesting that evidence best supports the adoption of year-round standard time. This updated statement cites new evidence and support for permanent standard time. It is the position of the AASM that the United States should eliminate seasonal time changes in favor of permanent standard time, which aligns best with human circadian biology. Evidence supports the distinct benefits of standard time for health and safety, while also underscoring the potential harms that result from seasonal time changes to and from daylight saving time. CITATION: Rishi MA, Cheng JY, Strang AR, et al. Permanent standard time is the optimal choice for health and safety: an American Academy of Sleep Medicine position statement. J Clin Sleep Med. 2024;20(1):121-125.


Assuntos
Ritmo Circadiano , Transtornos do Sono do Ritmo Circadiano , Humanos , Estados Unidos , Sono , Relógios Biológicos , Estações do Ano
2.
J Clin Sleep Med ; 18(8): 2041-2043, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35638127

RESUMO

This position statement provides guidance for age and weight considerations for using continuous positive airway pressure therapy in pediatric populations. The American Academy of Sleep Medicine commissioned a task force of experts in pediatric sleep medicine to review the medical literature and develop a position statement based on a thorough review of these studies and their clinical expertise. The American Academy of Sleep Medicine Board of Directors approved the final position statement. It is the position of the American Academy of Sleep Medicine that continuous positive airway pressure can be safe and effective for the treatment of obstructive sleep apnea for pediatric patients, even in children of younger ages and lower weights, when managed by a clinician with expertise in evaluating and treating pediatric obstructive sleep apnea. The clinician must make the ultimate judgment regarding any specific care in light of the individual circumstances presented by the patient, accessible treatment options, patient/parental preference, and resources. CITATION: Amos L, Afolabi-Brown O, Gault D, et al. Age and weight considerations for the use of continuous positive airway pressure therapy in pediatric populations: an American Academy of Sleep Medicine position statement. J Clin Sleep Med. 2022;18(8):2041-2043.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Academias e Institutos , Comitês Consultivos , Criança , Humanos , Sono , Apneia Obstrutiva do Sono/terapia , Estados Unidos
3.
J Clin Sleep Med ; 18(2): 685, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34705628
4.
J Clin Sleep Med ; 13(3): 479-504, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28162150

RESUMO

INTRODUCTION: This guideline establishes clinical practice recommendations for the diagnosis of obstructive sleep apnea (OSA) in adults and is intended for use in conjunction with other American Academy of Sleep Medicine (AASM) guidelines on the evaluation and treatment of sleep-disordered breathing in adults. METHODS: The AASM commissioned a task force of experts in sleep medicine. A systematic review was conducted to identify studies, and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process was used to assess the evidence. The task force developed recommendations and assigned strengths based on the quality of evidence, the balance of benefits and harms, patient values and preferences, and resource use. In addition, the task force adopted foundational recommendations from prior guidelines as "good practice statements", that establish the basis for appropriate and effective diagnosis of OSA. The AASM Board of Directors approved the final recommendations. RECOMMENDATIONS: The following recommendations are intended as a guide for clinicians diagnosing OSA in adults. Under GRADE, a STRONG recommendation is one that clinicians should follow under most circumstances. A WEAK recommendation reflects a lower degree of certainty regarding the outcome and appropriateness of the patient-care strategy for all patients. The ultimate judgment regarding propriety of any specific care must be made by the clinician in light of the individual circumstances presented by the patient, available diagnostic tools, accessible treatment options, and resources. Good Practice Statements: Diagnostic testing for OSA should be performed in conjunction with a comprehensive sleep evaluation and adequate follow-up. Polysomnography is the standard diagnostic test for the diagnosis of OSA in adult patients in whom there is a concern for OSA based on a comprehensive sleep evaluation.Recommendations: We recommend that clinical tools, questionnaires and prediction algorithms not be used to diagnose OSA in adults, in the absence of polysomnography or home sleep apnea testing. (STRONG). We recommend that polysomnography, or home sleep apnea testing with a technically adequate device, be used for the diagnosis of OSA in uncomplicated adult patients presenting with signs and symptoms that indicate an increased risk of moderate to severe OSA. (STRONG). We recommend that if a single home sleep apnea test is negative, inconclusive, or technically inadequate, polysomnography be performed for the diagnosis of OSA. (STRONG). We recommend that polysomnography, rather than home sleep apnea testing, be used for the diagnosis of OSA in patients with significant cardiorespiratory disease, potential respiratory muscle weakness due to neuromuscular condition, awake hypoventilation or suspicion of sleep related hypoventilation, chronic opioid medication use, history of stroke or severe insomnia. (STRONG). We suggest that, if clinically appropriate, a split-night diagnostic protocol, rather than a full-night diagnostic protocol for polysomnography be used for the diagnosis of OSA. (WEAK). We suggest that when the initial polysomnogram is negative and clinical suspicion for OSA remains, a second polysomnogram be considered for the diagnosis of OSA. (WEAK).


Assuntos
Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Academias e Institutos , Adulto , Humanos , Medicina do Sono , Inquéritos e Questionários
7.
J Clin Sleep Med ; 7(5): 531-48, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-22003351

RESUMO

Guidance is needed to help clinicians decide which out-of-center (OOC) testing devices are appropriate for diagnosing obstructive sleep apnea (OSA). A new classification system that details the type of signals measured by these devices is presented. This proposed system categorizes OOC devices based on measurements of Sleep, Cardiovascular, Oximetry, Position, Effort, and Respiratory (SCOPER) parameters.Criteria for evaluating the devices are also presented, which were generated from chosen pre-test and post-test probabilities. These criteria state that in patients with a high pretest probability of having OSA, the OOC testing device has a positive likelihood ratio (LR+) of 5 or greater coinciding with an in-lab-polysomnography (PSG)-generated apnea hypopnea index (AHI) ≥ 5, and an adequate sensitivity (at least 0.825).Since oximetry is a mandatory signal for scoring AHI using PSG, devices that do not incorporate oximetry were excluded. English peer-reviewed literature on FDA-approved devices utilizing more than 1 signal was reviewed according to the above criteria for 6 questions. These questions specifically addressed the adequacy of different respiratory and effort sensors and combinations thereof to diagnose OSA. In summary, the literature is currently inadequate to state with confidence that a thermistor alone without any effort sensor is adequate to diagnose OSA; if a thermal sensing device is used as the only measure of respiration, 2 effort belts are required as part of the montage and piezoelectric belts are acceptable in this context; nasal pressure can be an adequate measurement of respiration with no effort measure with the caveat that this may be device specific; nasal pressure may be used in combination with either 2 piezoelectric or respiratory inductance plethysmographic (RIP) belts (but not 1 piezoelectric belt); and there is insufficient evidence to state that both nasal pressure and thermistor are required to adequately diagnose OSA. With respect to alternative devices for diagnosing OSA, the data indicate that peripheral arterial tonometry (PAT) devices are adequate for the proposed use; the device based on cardiac signals shows promise, but more study is required as it has not been tested in the home setting; for the device based on end-tidal CO(2) (ETCO(2)), it appears to be adequate for a hospital population; and for devices utilizing acoustic signals, the data are insufficient to determine whether the use of acoustic signals with other signals as a substitute for airflow is adequate to diagnose OSA.Standardized research is needed on OOC devices that report LR+ at the appropriate AHI (≥ 5) and scored according to the recommended definitions, while using appropriate research reporting and methodology to minimize bias.


Assuntos
Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Apneia Obstrutiva do Sono/diagnóstico , Desenho de Equipamento , Humanos , Monitorização Ambulatorial/normas , Oximetria/instrumentação , Oximetria/métodos , Oximetria/normas , Pletismografia de Impedância/instrumentação , Pletismografia de Impedância/métodos , Pletismografia de Impedância/normas , Valor Preditivo dos Testes , Testes de Função Respiratória/instrumentação , Testes de Função Respiratória/métodos , Testes de Função Respiratória/normas , Transdutores de Pressão/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...