Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Strength Cond Res ; 22(4): 1101-7, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18545201

RESUMO

The effects of supplemental carbohydrate (CHO) ingestion on the performance of squats to exhaustion (STE) were investigated with eight resistance-trained men. Subjects participated in a randomized, counterbalanced, double-blind, placebo-controlled protocol with testing separated by 7 days. Subjects consumed 0.3g.kgCHO.bodymass or a placebo (PLC) of equal volume immediately before exercise and after every other successful set of squats. The STE consisted of sets of five repetitions at an intensity of 85% 1 repetition maximum (1RM). Performance measured as total sets (CHO 3.5 +/- 3.2, PLC 3.5 +/- 2.7), repetitions (CHO 20.4 +/-14.9, PLC 19.7 +/- 13.1), volume load (CHO 2928.7 +/- 2219.5 kg, PLC 2772.8 +/- 1951.4 kg), and total work (CHO 29.9 +/- 22.3 kJ, PLC 28.6 +/- 19.5 kJ) was not statistically different between the CHO and PLC treatments. The results suggest that CHO supplementation does not enhance performance of squats performed with 85% 1RM to volitional failure.


Assuntos
Carboidratos da Dieta/administração & dosagem , Educação Física e Treinamento/métodos , Adulto , Glicemia/análise , Método Duplo-Cego , Ácidos Graxos/sangue , Frequência Cardíaca/fisiologia , Humanos , Soluções Isotônicas/administração & dosagem , Ácido Láctico/sangue , Masculino , Esforço Físico/fisiologia
2.
J Strength Cond Res ; 19(3): 698-708, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16095428

RESUMO

The influence of different relative intensities on power output was investigated in the present study in order to identify the optimal load that maximizes power output during the hang power clean. Fifteen men (age: 22.1 +/- 2.0 years, height: 180.1 +/- 6.3 cm, and body mass: 89.4 +/- 14.7 kg) performed the hang power cleans on a forceplate at 30-90% of one repetition maximum (1RM). Peak power was maximized at 70% 1RM, which was, however, not significantly different from peak power at 50, 60, 80, and 90% 1RM. Average power also was maximized at 70% 1RM, which was not significantly different from average power at 40, 50, 60, 80, and 90% 1RM. It was concluded that (a) the relative intensity had a significant influence on power output, and (b) power output can be maximized at a submaximal load during the hang power clean.


Assuntos
Músculo Esquelético/fisiologia , Educação Física e Treinamento/métodos , Levantamento de Peso/fisiologia , Adulto , Análise de Variância , Fenômenos Biomecânicos , Teste de Esforço , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...