Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Diagn Res ; 11(8): ZC49-ZC52, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28969273

RESUMO

INTRODUCTION: To date, many orthodontist corrects malocclusion based on patients aesthetic concern and fails to correct the compensatory curves. This scenario is due to less insight on understanding relationship of compensatory curves and its correlation in treatment prognosis. AIM: The purpose of this study was to evaluate the correlation between the curve of Spee, curve of Monson and curve of Wilson, their influence on dentoskeletal morphology and their contribution to occlusal stability. MATERIALS AND METHODS: This study included 104 non-orthodontic models. The study casts were subdivided into two groups, Group-I consist 52 non- orthodontic models with Class-I molar relationship and Group-II consist of 52 non- orthodontic models with Class-II molar relationship. Curve of Spee was measured with digital vernier caliper, curve of Monson estimated using specially made sphere (7″inch, 8″ inch and 9″inch) and curve of Wilson was evaluated using Cone Beam Computed Technology (CBCT). RESULTS: Mean value for curve of Spee obtained for Group I and Group II is 1.844 mm and 3.188 mm. For curve of Monson, the mean value obtained for Group I and Group-II is 7.65 inches and 7.40 inches. The mean degree obtained for the curve of Wilson for Group I and Group-II is 12.05 and 16.49. The result showed positive correlation between curve of Spee and curve of Wilson and no correlation between curve of Monson and curve of Wilson and no correlation between curve of Spee and curve of Monson. The Pearson correlation coefficient analysis from the study confirmed these results. CONCLUSION: The results showed positive correlation between curve of spee and curve of Wilson. The data found in this study can be applied clinically for Class I and Class II malocclusion patients on diagnosis and treatment planning.

2.
J Contemp Dent Pract ; 18(6): 458-462, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28621274

RESUMO

AIM AND OBJECTIVE: The aim of the study is to analyze and compare the variation of lumen size and thickness of the elastomeric colored modules when immersed in four selected dietary media. MATERIALS AND METHODS: Sample size of 40 modules on each color - such as red, blue, green, and black - was taken and immersed in four dietary media (artificial saliva, coke mixed with artificial saliva, turmeric mixed with artificial saliva, and coffee mixed with artificial saliva). Beakers containing different dietary media and color modules are kept in the incubator at 37°C for 72 hours. After incubation period, all the segments of module strips removed from the dietary media were placed under the electric lamp and photographs were taken using Canon camera (SX400 IS). Photographs were transferred to GIMP software, and lumen size and thickness variation in the modules was measured. RESULTS: Statistical analysis were performed using analysis of variance and t-test in Statistical Package for the Social Sciences software. It showed significant difference in thickness of black module in all dietary media. Significant difference existed between all the lumen sizes of four color modules in four dietary media. CONCLUSION: This study was done to identify the material that has more changes in physical properties when exposed to various dietary media. CLINICAL SIGNIFICANCE: According to the results obtained, black color modules have increased in lumen size in all dietary media. In thickness, red color module showed less variation and black color module exhibited more variation.


Assuntos
Cor , Elastômeros , Estética Dentária , Aparelhos Ortodônticos , Bebidas Gaseificadas , Café , Curcuma , Humanos , Imersão , Saliva Artificial
3.
J Contemp Dent Pract ; 17(5): 372-6, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27443362

RESUMO

BACKGROUND: Recent metallurgical research and advancement in material science has benefited orthodontists in the selection of an appropriate wire size and alloy type, which is necessary to provide an optimum and predictable treatment results. The purpose of the study was to clinically evaluate and compare the surface characteristics of 16 x 22 stainless steel, Titanium molybdenum alloy, timolium, and titanium-niobium before and after placing them in a patient's mouth for 3 months using a scanning electron microscope (SEM). MATERIALS AND METHODS: The total sample size was 40, which were divided into four groups (group 1 - stainless steel wires, 10 samples, group 2 - TMA wires, 10 samples, group 3 - timolium wires, 10 samples, and group 4 - titanium-niobium wires, 10 samples), and these were further subdivided into 5 each. The first subgroup of five samples was placed in the patient's mouth and was evaluated under SEM, and another subgroup of five samples was directly subjected to the SEM. RESULTS: Scanning electron microscopic evaluation of surface characteristics of unused 16 x 22 rectangular stainless steel wire under 500 x magnification showed an overall smooth surface. Stainless steel wire samples placed in the patient's mouth showed black hazy patches, which may be interoperated as areas of stress. TMA unused wires showed multiple small voids of areas and small craters with fewer elevated regions. The TMA wire samples placed in the patient's mouth showed black hazy patches and prominent ridges, making the wire rougher. Timolium unused archwires showed heavy roughness and voids, whereas wires tested in the patient's mouth showed homogeneous distribution of deep cracks and craters. Unused titanium-niobium archwires showed uniform prominent striations and ridges with occasional voids, whereas wires used in the patient's mouth showed prominent huge voids that could be interpreted as maximum stress areas. CONCLUSION: Stainless steel (group 1) used and unused wires showed smooth surface characteristics when compared with all the other three groups followed by timolium, which was superior to titanium-niobium wires and TMA wires. CLINICAL SIGNIFICANCE: Timolium wires are superior to titanium-niobium wires and TMA wires.


Assuntos
Nióbio , Braquetes Ortodônticos , Fios Ortodônticos , Aço Inoxidável , Titânio , Ligas Dentárias , Análise do Estresse Dentário , Elasticidade , Teste de Materiais , Microscopia Eletrônica de Varredura , Estresse Mecânico , Propriedades de Superfície
4.
J Int Soc Prev Community Dent ; 6(Suppl 1): S79-83, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27195234

RESUMO

Early screening and diagnosis help in preventing and intercepting the severity of the malocclusion which helps in addressing the esthetic and functional concerns. Growth modulation such as mandibular advancement has been an effective procedure in orthodontics. Mandibular growth advancer (MGA) and PowerScope are gaining popularity recently as these are effective in achieving the mandibular advancement and ease of fabrication, placement, and wear. MGA was fabricated by making the upper and lower splints separately and are placed in the oral cavity by joining the two splints in the new construction bite using cold cure, MGA when worn during growth phase helps in condylar remodeling in the temporomandibular joint thus helps in advancement of the mandible. The proclination of the upper anteriors in Class II division 1 can be moved lingually by activating the labial bow in the splint. Dr. Andy Hayes worked in conjunction with American orthodontics developed PowerScope. PowerScope delivers Class II correction with a combination of patient comfort and ease of use that was unmatched among other appliances. This ready to use chairside solution required no laboratory setup, making for a much quicker, and easier installation process and appointment. PowerScopes high quality, fixed one-piece design requires no patient compliance. These superior qualities of PowerScope help in correction of Class II skeletal growing patient in conjunction with fixed orthodontic therapy. MGA and PowerScope were chosen as a functional appliance for this study, which shows decreased ANB angle and effective mandible length was increased.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...