Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Asian Pac J Cancer Prev ; 24(5): 1659-1666, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37247286

RESUMO

BACKGROUND: To develop a dosimetric tool to estimate the dose delivered in the presence of air pockets with EBT3 film while simulating the conditions of vaginal vault brachytherapy (VVBT) with 3.0 diameter cylindrical applicator at a prescription dose distance of 5mm from the surface of it. MATERIALS AND METHOD: Six acrylic plates (10 cm x 10 cm, 0.5 cm thick) with four different types of slots were designed and produced locally. They can hold a cylindrical vaginal brachytherapy applicator in the centre, air equivalent material from the applicator's surface [(sizes 4.5 mm (A), 3.0 mm (B), and 2.0 mm (C)], EBT3 film at the prescribed dose distance, and holder rods. Plates were layered together with acrylic rods and assembled in a holding box in a water phantom. Three treatment plans done in TPS with prescription doses of 2 Gy, 3 Gy, and 4 Gy at 5.0 mm with a treatment length of 6 cm, and were executed in Co-60-based HDR brachytherapy unit (M/s SagiNova, Germany) with & without the placement of air equivalent material, and the dose received at slot locations A, B, & C were noted. RESULTS: The mean percentage deviation of measured dose without and with presence of air pocket at A, B and C was 13.9%, 11.0% and 6.4% respectively for all dose prescriptions. As the air pocket size expanded radially from 2.0 mm to 4.5 mm, the increase in dosage ranged from 6.4% to 13.9% which was due to the fact that the film was held at dosage prescription distance and the lack of attenuation of photons radially through air pocket. CONCLUSIONS: The present study can be carried out with a 3D printed phantom that simulates VVBT application having air pockets of different dimensions at different locations and also can be analyzed with Monte Carlo simulations.


Assuntos
Braquiterapia , Feminino , Humanos , Dosagem Radioterapêutica , Braquiterapia/métodos , Radiometria/métodos , Vagina , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Doses de Radiação
2.
J Med Phys ; 39(4): 247-50, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25525313

RESUMO

External beam radiotherapy (EBRT) for carcinoma of uterine cervix is a basic line of treatment with three dimensional conformal radiotherapy (3DCRT) in large number of patients. There is need for an established method for verification dosimetry. We tried to document absorbed doses in a group of carcinoma cervix patients by inserting a 0.6 cc Farmer type ion chamber in the vaginal cavity. A special long perspex sleeve cap is designed to cover the chamber for using in the patient's body. Response of ionization chamber is checked earlier in water phantom with and without cap. Treatment planning was carried out with X-ray computed tomography (CT) scan and with the chamber along with cap in inserted position, and with the images Xio treatment planning system. Three measurements on 3 days at 5-6 fraction intervals were recorded in 12 patients. Electrometer measured charges are converted to absorbed dose at the chamber center, in vivo. Our results show good agreement with planned dose within 3% against prescribed dose. This study, is a refinement over our previous studies with transmission dosimetry and chemicals in ampules. This preliminary work shows promise that this can be followed as a routine dose check with special relevance to new protocols in the treatment of carcinoma cervix with EBRT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...