Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36983397

RESUMO

BACKGROUND: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. AIM: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. METHODS AND RESULTS: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. CONCLUSIONS: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.

2.
J Clin Med ; 11(2)2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35054137

RESUMO

Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.

3.
Am Heart J ; 158(5): 822-828.e3, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19853704

RESUMO

BACKGROUND: The choice of radiographic contrast media for use in patients at increased risk of contrast-induced nephropathy (CIN) is of ongoing interest. METHODS: The current study is a prospective, multicenter, randomized, double-blind design comparing the renal effects of the non-ionic, iso-osmolal agent, iodixanol, versus the non-ionic, low-osmolal agent, iopamidol, in 526 subjects with impaired baseline renal function (chronic kidney disease) and diabetes mellitus undergoing diagnostic and/or therapeutic coronary angiographic procedures. The co-primary end points were the peak increase in serum creatinine (SCr) and the incidence of CIN (increase > or =0.5 mg/dL) in SCr from baseline within 3 days of receiving contrast media. RESULTS: In 418 evaluable subjects with complete postcontrast media SCr data, the median peak increase in SCr in the iodixanol arm was 0.10 mg/dL, whereas in the iopamidol arm, the median peak increase was 0.09 mg/dL (P = .13). The overall CIN incidence was 10.5% (11.2% % in the iodixanol arm and 9.8% in the iopamidol arm, P = .7). The volume of contrast media, volume of saline administered, frequency of coronary interventional procedures, and severity of baseline kidney disease and of diabetes mellitus were similar between treatments. CONCLUSIONS: In the present study, the overall rate of CIN in patients with chronic kidney disease and DM undergoing coronary angiographic procedures was 10.5%. There was no significant difference between iodixanol and iopamidol in either peak increase in SCr or risk of CIN.


Assuntos
Meios de Contraste/toxicidade , Angiografia Coronária/efeitos adversos , Iopamidol/toxicidade , Ácidos Tri-Iodobenzoicos/toxicidade , Idoso , Creatinina/sangue , Nefropatias Diabéticas/sangue , Método Duplo-Cego , Feminino , Humanos , Falência Renal Crônica/sangue , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...