Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Int J Clin Oncol ; 15(5): 433-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20405154

RESUMO

BACKGROUND: Our aim was to evaluate the clinical significance of the negative-balance isolated pelvic perfusion (NIPP) method using ultrahigh-dose cisplatin (CDDP) for ten cases of invasive bladder cancer with poor risk such as high-grade cancer, advanced clinical stage, or appearance of hydronephrosis. METHODS: A CDDP dosage of 200-300 mg/body was used under the NIPP method. To confirm safety and efficacy, peripheral blood, pelvic arterial blood, pelvic venous blood, and urine were collected for sampling of the platinum (Pt) concentrations. These samples were investigated and compared with those following previous intraarterial chemotherapy sessions. RESULTS: The Pt concentrations in pelvic blood under intraarterial chemotherapy and NIPP were 5.97 ± 2.06 and 24.15 ± 4.61 µg/ml, respectively. By contrast, the Pt concentration in peripheral blood under NIPP was half the level under conventional intraarterial chemotherapy. No severe adverse events were found in terms of gastrointestinal and hematological toxicity, but renal function was impaired in some cases. Pathological or surgical complete response (CR) was achieved in five of ten cases (50%) in spite of the group being poor risk, and bladder preservation was possible in all the CR cases. Patients with CR experienced survival in all terms of observation. CONCLUSIONS: The NIPP method was able to deliver high levels of CDDP concentration in pelvis cavity without severe adverse events. The NIPP method makes it possible to achieve CR for the patients with invasive bladder cancer with poor risk who rejected cystectomy.


Assuntos
Antineoplásicos/administração & dosagem , Quimioterapia do Câncer por Perfusão Regional , Cisplatino/administração & dosagem , Neoplasias da Bexiga Urinária/tratamento farmacológico , Idoso , Antineoplásicos/efeitos adversos , Antineoplásicos/sangue , Antineoplásicos/farmacocinética , Cisplatino/efeitos adversos , Cisplatino/sangue , Cisplatino/farmacocinética , Feminino , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Pelve , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Neoplasias da Bexiga Urinária/mortalidade , Neoplasias da Bexiga Urinária/patologia
2.
J Magn Reson Imaging ; 28(3): 783-90, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18777556

RESUMO

PURPOSE: To determine the appropriate dose of contrast medium for moving-table MR angiography (MT-MRA) from the abdominal aorta to the ankle by comparing visualization with different doses of meglumine gadopentetate (Gd-DTPA) administered in crossover fashion to normal volunteers. MATERIALS AND METHODS: Twelve healthy adults underwent imaging after crossover administration of 0.1 and 0.2 mmol/kg of Gd-DTPA in random order. Continuous MT-MRA was performed with a fast 3D spoiled gradient echo sequence without parallel imaging technique. Visualization was evaluated in a total of 252 arteries by three blinded readers who independently rated arterial visualization using a 5-grade scale. Signal intensity was determined and the blood concentration of Gd-DTPA was estimated. RESULTS: Arterial visualization in the lower leg region was significantly better with a dose of 0.2 mmol/kg than with 0.1 mmol/kg (P<0.001). For all regions assessed the estimated blood Gd-DTPA level was significantly higher with 0.2 mmol/kg than with 0.1 mmol/kg (abdominal aorta, P=0.030; superficial femoral artery, P<0.001; posterior tibial artery, P=0.039). The vascular signal enhancement ratio and artery-to-muscle signal ratio were significantly higher in the upper leg and lower leg regions at 0.2 mmol/kg. CONCLUSION: With continuous MT-MRA imaging from the abdomen to the ankle in normal volunteers, better arterial visualization and superior contrast were achieved with 0.2 mmol/kg of Gd-DTPA.


Assuntos
Aorta Abdominal/anatomia & histologia , Artérias/anatomia & histologia , Gadolínio DTPA/administração & dosagem , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Meios de Contraste/administração & dosagem , Estudos Cross-Over , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Hepatogastroenterology ; 54(78): 1895-7, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18019743

RESUMO

Gastric artery aneurysm is rare and accounts for fewer than 5% of all splanchnic artery aneurysms. The diagnosis is usually established during emergent surgery or at autopsy because warning signs or symptoms are vague, absent, or unrecognized. Nearly 80% of the patients reported with gastric artery aneurysm die. Preoperative diagnosis of gastric artery aneurysm is an essential contribution to treat safely and effectively the aneurysms and to reduce the high mortality rate. We report a successful treatment with transcatheter arterial embolization (TAE) of two cases of a left gastric artery aneurysm diagnosed using contrast-enhanced computed tomography. Case 1 was a ruptured aneurysm with shock. Embolization was successfully performed as the left gastric artery aneurysm was diagnosed by computed tomography at rupture. Case 2 had multiple hepatocellular carcinomas, and a left gastric artery aneurysm was diagnosed by follow-up computed tomography. Embolization was successfully performed for the left gastric artery aneurysm, and chemoembolization was repeatedly performed for multiple hepatocellular carcinomas after embolization of the aneurysm.


Assuntos
Aneurisma/terapia , Artéria Celíaca/patologia , Embolização Terapêutica/métodos , Estômago/irrigação sanguínea , Idoso , Angiografia/métodos , Meios de Contraste/farmacologia , Feminino , Humanos , Inflamação , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
4.
J Comput Assist Tomogr ; 31(4): 600-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17882040

RESUMO

OBJECTIVE: To evaluate regional, remote, and global effects of percutaneous transluminal septal myocardial ablation (PTSMA) in hypertrophic obstructive cardiomyopathy (HOCM) using magnetic resonance (MR) imaging. METHODS: Twenty-one patients with HOCM underwent cine and delayed contrast-enhanced MR imaging. The regional effects of ablated myocardium as well as remote and global effects of PTSMA were assessed. RESULTS: The ablated interventricular septal myocardium was hyperenhanced and thinned after successful PTSMA. Decreases in posterior wall thickness and myocardial mass were observed more than 12 weeks after PTSMA. Decreases in posterior wall thickness, myocardial mass, and left atrial diameter were observed in patients without myocardial hyperenhancement before PTSMA. Neither reduction nor increase in hyperenhancing myocardium, except for the ablated myocardium, was observed after PTSMA. CONCLUSIONS: Cardiac MR imaging showed regional, remote, and global effects of PTSMA on the myocardium in HOCM and might indicate patients with a good global response to PTSMA.


Assuntos
Angioplastia Coronária com Balão , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Filmes Cinematográficos
5.
J Cancer Res Clin Oncol ; 133(10): 741-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17503082

RESUMO

PURPOSE: Negative-balance isolated pelvic perfusion (NIPP) is used to administer high doses of anticancer drugs such as cisplatin to patients with advanced cancer of the pelvic region. Although the drugs are intended to be specifically delivered to the pelvis, their leakage into the systemic circulation can cause acute renal failure. This study examines the loading volume required for preservation of renal function during anesthesia of NIPP. METHODS: Pelvic cancer patients were assigned to NIPP according to its enrollment criteria. Patients with heart failure, uncontrollable hypertension, renal failure, pulmonary disease or contraindication for the contrast media were excluded. We compared the current anesthesia management regime with a previous protocol, with regard to the loading volume and renal function as assessed by the calculated glomerular filtration rate (GFR). The correlation between the total loading volume and the GFR ratio (GFR after NIPP/GFR before NIPP) was evaluated to define adequate volume loading. RESULTS: The GFR ratios were 0.86 +/- 0.29 and 1.12 +/- 0.25 for the previous and current procedures, respectively. The regression line showed that a minimum loading volume of 28.8 ml kg(-1) h(-1) was required to maintain a GFR ratio of > or =1. CONCLUSIONS: A large volume infusion preserves the GFR despite high-dose cisplatin administration by NIPP.


Assuntos
Antineoplásicos/administração & dosagem , Quimioterapia do Câncer por Perfusão Regional/efeitos adversos , Quimioterapia do Câncer por Perfusão Regional/métodos , Cisplatino/administração & dosagem , Nefropatias/prevenção & controle , Feminino , Taxa de Filtração Glomerular , Humanos , Nefropatias/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Perfusão
6.
Eur Radiol ; 17(7): 1875-8, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17242872

RESUMO

The purpose of this study was to assess the usefulness of silicone-selective multishot echo-planar imaging (EPI) for the rapid magnetic resonance imaging (MRI) survey of breast implants. Twenty patients with bilateral breast implants underwent MRI. The use of inversion recovery and magnetization transfer pulses led to silicone-selective images. The rapid MRI survey required only 43 s, which accurately distinguished between silicone and non-silicone materials in the implants, and therefore induced the final MRI sequences appropriate for the detailed characterization of the implants. In 5 of the 20 patients, the rapid MRI survey showed implanted materials that were not indicated from clinical information. This silicone-selective multishot EPI allows a rapid survey of breast implants, which is useful to avoid unnecessary sequences in these patients.


Assuntos
Implantes de Mama , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Silicones , Adulto , Idoso , Mama/patologia , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Sensibilidade e Especificidade , Estudos de Tempo e Movimento
7.
Heart Vessels ; 21(5): 334-7, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17151825

RESUMO

Inflammatory abdominal aortic aneurysm (AAA) is an aortic aneurysm of unknown etiology characterized by a thickened aneurysmal wall, perianeurysmal and retroperitoneal fibrosis, and adhesions to adjacent organs. We encountered a case of inflammatory AAA, which developed from an ordinary atherosclerotic AAA over a period of 14 months, with a rapid increase of 48 mm in the maximum diameter of the aneurysm over 12 days. This report describes the evaluation of the serial change by 16-channel multidetector-row computed tomographic (MDCT) angiography.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/terapia , Doenças da Aorta/complicações , Aterosclerose/complicações , Fibrose , Seguimentos , Humanos , Inflamação/diagnóstico por imagem , Inflamação/terapia , Masculino , Tomografia Computadorizada por Raios X
8.
J Nippon Med Sch ; 73(5): 248-57, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17106175

RESUMO

Erectrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) can be used to assess myocardial perfusion and left ventricular function simultaneously. Various clinical applications of gated SPECT and their usefulness have been reported. The functional variables that can be determined with gated SPECT have been limited to systolic indices. Therefore, we evaluated left ventricular diastolic function with gated SPECT using data obtained from various frames per cardiac cycle and found that date generated from 32-frames are suitable for clinical use. Serial assessment of left ventricular function was also performed during bicycle exercise and dobutamine stress by means of gated SPECT using short-time data collection. These techniques, therefore, have the potential to provide useful information for evaluating myocardial conditions, such as hibernation and residual ischemia in infarct areas. Recently, we have developed a new technique for three-dimensional registration of CT coronary angiography (CTCA) and ECG-gated myocardial perfusion SPECT. This technique of registration may assist the integration of information from gated SPECT and CTCA and may have clinical application for the diagnosis of ischemic heart disease. These various applications would contribute to the development of nuclear cardiology.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda/fisiologia , Angiografia Coronária , Dobutamina , Eletrocardiografia , Teste de Esforço , Ácidos Graxos/metabolismo , Humanos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada por Raios X
9.
J Nippon Med Sch ; 73(5): 258-64, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17106176

RESUMO

OBJECTIVES: We assessed the usefulness of (201)thallous chloride (TlCl)/(123)I-beta-methyl iodophenyl pentadecanoic acid (BMIPP) dual-isotope single-photon emission computed tomography (SPECT) to identify the "no-reflow phenomenon," defined as inadequate myocardial perfusion through a given segment of the coronary circulation without angiographic evidence of mechanical vessel obstruction. METHODS: (201)TlCl/(123)I-BMIPP SPECT was performed in 73 patients within approximately 1 week of initial acute myocardial infarction (AMI) after percutaneous coronary intervention (PCI). We divided the left ventricular myocardium into 17 segments on each SPECT image and scored tracer accumulation in each segment with a five-point scoring system according to the American Heart Association criteria. Total severity scores were calculated by summing the scores for all 17 segments. The mismatch ratio between myocardial perfusion and metabolism was derived from the (201)TlCl and (123)I-BMIPP total severity scores: mismatch ratio=((123)I-BMIPP total severity score -(201)TlCl total severity score)/(123)I-BMIPP total severity score. Patients were classified according to Thrombolysis in Myocardial Infarction (TIMI) flow grade as having TIMI reflow grade 0-I (TIMI 0-I reflow group; n=11), II (TIMI II reflow group; n=17) and III (TIMI III reflow group; n=45). The TIMI III reflow group was subdivided into two groups with (201)TlCl total severity scores of < or =13 (TIMI III (A) reflow group; n=36) and > or =14 (TIMI III (B) reflow group; n=9), respectively. RESULTS: The mismatch ratios in the TIMI II (0.4 +/- 0.3) and TIMI III (0.4 +/- 0.2) reflow groups were significantly higher than that in the TIMI 0-1 reflow group (0.1 +/- 0.1, p<0.05). Although coronary angiography revealed TIMI III flow after reperfusion, the mismatch ratios in the TIMI III (B) reflow group (0.2 +/- 0.1) and in the TIMI 0-I reflow group (0.1 +/- 0.1) were significantly lower than that in the TIMI III (A) reflow group (0.4 +/- 0.2, p<0.01), reflecting noneffective recanalization (so called no-reflow phenomenon). CONCLUSION: (201)TlCl/(123)I-BMIPP dual-isotope myocardial SPECT reveals the biochemical degree of the no-reflow phenomenon, whereas coronary angiography shows recanalized vascular flow only. Dual-isotope myocardial SPECT might be useful for evaluating reperfusion therapy.


Assuntos
Circulação Coronária/fisiologia , Ácidos Graxos , Radioisótopos do Iodo , Iodobenzenos , Infarto do Miocárdio/diagnóstico por imagem , Radioisótopos de Tálio , Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia
10.
AJR Am J Roentgenol ; 187(3): W290-8, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16928907

RESUMO

OBJECTIVE: The purpose of our study was to assess the efficacy of transcatheter arterial embolization for pancreaticoduodenal artery aneurysms. CONCLUSION: We concluded that transcatheter arterial embolization is the initial and definitive therapeutic choice for pancreaticoduodenal artery aneurysms, with a possible option to perform surgery after embolization.


Assuntos
Aneurisma/terapia , Embolização Terapêutica/métodos , Circulação Esplâncnica , Idoso , Aneurisma/patologia , Cateterismo , Duodeno/irrigação sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/irrigação sanguínea , Estudos Retrospectivos , Resultado do Tratamento
11.
Heart Vessels ; 21(4): 267-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16865306

RESUMO

Persistent sciatic artery is a rare but potentially significant vascular anomaly that is associated with a high incidence of aneurysm formation and limb-threatening ischemic complications. The diagnosis of persistent sciatic artery has usually been made by conventional angiography. We report a case of occluded and patent persistent sciatic arteries in which multidetector-row computed tomographic angiography allowed a definitive diagnosis of this rare vascular condition.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Malformações Arteriovenosas/diagnóstico por imagem , Artéria Ilíaca/anormalidades , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia/métodos , Arteriopatias Oclusivas/etiologia , Malformações Arteriovenosas/complicações , Feminino , Humanos
12.
World J Gastroenterol ; 12(26): 4214-8, 2006 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-16830378

RESUMO

AIM: To observe the dynamic changes of liver microcirculation in vivo after arterial embolization with degradable starch microspheres (DSM). METHODS: DSM were injected into the proper hepatic artery through a silastic tube inserted retrogradely in gastroduodenal artery (GDA) of SD rats. Fluorescent microscopy was used to evaluate the dynamic changes of blood flow through the terminal portal venules (TPVs), sinusoids and terminal hepatic venules (THVs). The movements of DSM debris were also recorded. Six hours after injection of DSM, percentages of THVs with completely stagnant blood flow were recorded. RESULTS: Two phases of blood flow change were recorded. In phase one: after intra-arterial injection of DSM, slow or stagnant blood flow was immediately recorded in TPVs, sinusoids and THVs. This change was reversible, and blood flow resumed completely. In phase two: after phase one, blood flow in TPVs changed again and three patterns of blood flow were recorded. Six hours after DSM injection, 36.9% +/- 9.2% of THVs were found with completely stagnant blood flow. CONCLUSION: DSM can stop the microcirculatory blood flow in some areas of liver parenchyma. Liver parenchyma supplied by arteries with larger A-P shunt is considered at a higher risk of total microcirculatory blood stagnation after injection of DSM through hepatic artery.


Assuntos
Embolização Terapêutica/métodos , Artéria Hepática/fisiologia , Fígado/irrigação sanguínea , Microcirculação/fisiologia , Amido/administração & dosagem , Animais , Injeções Intra-Arteriais , Fígado/fisiologia , Microscopia de Fluorescência , Ratos , Ratos Sprague-Dawley , Fluxo Sanguíneo Regional/fisiologia , Vênulas/fisiologia
13.
Comput Med Imaging Graph ; 30(3): 147-51, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16713177

RESUMO

Delayed contrast-enhanced inversion recovery (IR) gradient-echo MR imaging has been applied to several cardiac diseases, including myocarditis, sarcoidosis, hypertrophic cardiomyopathy, and myocardial damages induced by medical procedures. Although a preliminary study has indicated the usefulness of this imaging for the detection of right ventricular (RV) myocardial damage associated with arrhythmogenic right ventricular cardiomyopathy, the null points of the RV myocardium have not been assessed on contrast-enhanced IR MR imaging. In this study, the null points of the RV and left ventricular (LV) myocardia were evaluated using an IR fast multi-shot echo-planar imaging (Look-Locker sequence) in 26 patients with various cardiac diseases. In nine of the 26 patients, the null points of the RV myocardium were shorter than those of the LV myocardium in the Look-Locker sequence. The RV myocardial signals were significantly higher than the LV myocardial signals in delayed contrast-enhanced MR images. Thus, more attention should be paid to evaluation of the late enhancement of the RV myocardium, and delayed contrast-enhanced MR imaging with a shorter inversion time may be required in some cases.


Assuntos
Doenças Cardiovasculares/diagnóstico , Imagem Ecoplanar/métodos , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Interpretação Estatística de Dados , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade
14.
Clin Imaging ; 30(2): 127-31, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16500544

RESUMO

This study aimed to evaluate magnetic resonance (MR) imaging appearances of 11 gastrointestinal stromal tumors in the abdomen and pelvis and compared them with some histological findings. Gastrointestinal stromal tumor showed nonhomogeneous signal intensity and included hemorrhage in large tumors. Gastrointestinal stromal tumors showed a wide variety of enhancement, and contrast enhancement of the tumor was consistent with mitosis index as well as the largest diameter of the tumor. Contrast-enhanced MR imaging may be useful in the assessment of tumor activity.


Assuntos
Tumores do Estroma Gastrointestinal/patologia , Imageamento por Ressonância Magnética/métodos , Cavidade Abdominal , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve
15.
Cardiovasc Intervent Radiol ; 29(1): 155-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-15983859

RESUMO

A distal pulmonary artery perforation was successfully occluded by percutaneous microcoil embolization via a microcatheter. Microcoil embolization is a reasonable alternative therapeutic approach for this rare complication of pulmonary interventional procedures.


Assuntos
Embolização Terapêutica/métodos , Artéria Pulmonar/lesões , Trombectomia/efeitos adversos , Idoso , Angiografia , Feminino , Humanos , Doença Iatrogênica
16.
Hepatogastroenterology ; 52(65): 1313-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16201064

RESUMO

BACKGROUND/AIMS: The aim of this study is to prove the hemodynamic change in distribution of splenic venous flow in the liver, especially in the cirrhotic liver, and to reveal and evaluate a participation of splenic venous flow in regeneration or enlargement of the hepatic lobe. METHODOLOGY: We studied the distribution of splenic venous flow in the liver of patients with normal liver (NL group, n=15), chronic hepatitis (CH group, n=8), and liver cirrhosis (LC group, n=13) with the technique of scintiphotosplenoportography after percutaneous intrasplenic injection of Technetium-99m-diethylenetriaminepentaacetic acid-galactosyl-human serum albumin. The index of splenic venous flow volume per unit hepatocytes (Vunit) was calculated in each hepatic lobe. To compare V value of the left lobe (VLunit) with that of the right lobe (VRunit), predominant index of the left lobe (L/R index) was defined as L/R index = VLunit/VRunit. RESULTS: The median (interquartile range) of L/R index of the LC group; 1.22 (1.06-1.70) was significantly higher than that of the NL group; 0.83 (0.66-0.92), p<0.001 and the CH group; 0.79 (0.69-0.92), p<0.001. CONCLUSIONS: L/R index reflects the change of portal hemodynamics in cirrhotic liver and is useful for discrimination between noncirrhosis and cirrhosis. These results suggest that in the liver exposed to continuous damages, splenic venous blood promotes liver fibrosis in the right lobe and eventually flows more into the left lobe with milder fibrosis.


Assuntos
Cirrose Hepática/fisiopatologia , Fígado/irrigação sanguínea , Baço/irrigação sanguínea , Idoso , Feminino , Humanos , Regeneração Hepática/fisiologia , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Fluxo Sanguíneo Regional , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m
17.
Gan To Kagaku Ryoho ; 32(10): 1431-6, 2005 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-16227743

RESUMO

A clinical study on the use of porous gelatin particles(sterile gelatin embolization material, YM 670, Gelpart) in transcatheter arterial embolization (TAE) was performed in patients with hepatocellular carcinoma, and the efficacy (embolization,anti-tumor effect, recanalization and operationality) and safety (tolerability) were studied. An additive agent comprising porous gelatin particles and low osmolarity contrast media was administered peripherally through a catheter into the hepatic artery proper of 63 patients with hepatocellular carcinoma. Good hepatic arterial embolization was confirmed in all cases (embolization: 100%), and a tumor necrosis effect was obtained in most cases (35/62 patients, 56.5%). Moreover, operationality was assessed as "highly easy to use" or "easy to use" in all cases. Frequencies of adverse events in which a relationship to TAE was not excluded and abnormalities of clinical laboratory data were high at 71.4% and 9 8.4%, respectively. The most common adverse reactions were pyrexia, abdominal pain, queasiness and blood pressure increase;abnormalities in clinical laboratory data included hepatic function with increased AST (GOT), increased ALT (GPT), decreased cholinesterase, increased LDH and increased total bilirubin. These adverse reactions and abnormalities in clinical laboratory data, however, were transient and attributed to the TAE procedure itself, and no adverse reactions related to YM 670 as an embolic material were observed. In addition, with regard to tolerability (safety), the treatment was assessed as suitable for use in all the present cases.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Gelatina/administração & dosagem , Neoplasias Hepáticas/terapia , Adulto , Idoso , Feminino , Artéria Hepática , Humanos , Masculino , Pessoa de Meia-Idade
18.
Ann Nucl Med ; 19(5): 379-86, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16164194

RESUMO

UNLABELLED: The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. CONCLUSIONS: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.


Assuntos
Vasos Coronários/diagnóstico por imagem , Dobutamina , Ácidos Graxos/sangue , Imagem do Acúmulo Cardíaco de Comporta/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/metabolismo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/metabolismo , Eletrocardiografia , Teste de Esforço/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/complicações , Estatística como Assunto , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/etiologia
19.
Nephron Clin Pract ; 101(3): c150-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16015005

RESUMO

BACKGROUND: Radiographic contrast media (CM) induce renal vasoconstriction and may initiate induced nephropathy. Endothelin (ET), a vasoconstrictor, and nitric oxide (NO), a vasodilator, which are synthesized in the kidney by the vascular endothelium as well as by tubular epithelial and glomerular mesangial cells, are key modulators of renal circulation after CM administration. Intravascular CM, in addition, induces pronounced diuresis and natriuresis. The aim of the present study was to evaluate and compare changes in endogenous vasoactive mediators and contrast-induced natriuresis after CM administration. METHODS: Diagnostic angiographic procedures were performed in 14 patients (9 males and 5 females) using the non-ionic CM Iopamidol. Before and immediately after angiography, venous blood and urine samples were obtained. The urinary excretion of ET-1 and nitrates/nitrites (NOx), and the fractional excretion of sodium (FENa) were measured and analyzed. RESULTS: The urinary excretion of both ET-1 and NOx increased significantly (p < 0.05) after angiography, and urinary ET-1 and NOx excretion was correlated with an increase in FENa (p < 0.05). CONCLUSION: Exposure to CM in humans is associated with an increase in urinary ET and NOx. The excretion of sodium following CM administration is associated with an increase in urinary ET and NOx. ET and NO might be important in the renal change in humans after CM administration.


Assuntos
Meios de Contraste/efeitos adversos , Endotelina-1/urina , Natriurese/efeitos dos fármacos , Óxido Nítrico/urina , Idoso , Creatinina/sangue , Feminino , Humanos , Nefropatias/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Vasoconstrição/efeitos dos fármacos
20.
Ann Nucl Med ; 19(3): 207-15, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15981674

RESUMO

OBJECTIVE: In this study, we describe a new technique for three-dimensional registration of CT coronary angiography (CTCA) and gated myocardial perfusion SPECT. METHODS: Twelve patients with known or suspected CAD who underwent CTCA and gated SPECT were enrolled retrospectively. Coronary arteries and their branches were traced using CTCA data manually and reconstructed in three-dimensions. Gated SPECT data were registered and mapped to a left ventricle binary model extracted from CTCA data using manual, rigid and nonrigid registration methods. RESULTS: Three-dimensional reconstruction and volume visualization of both modalities were successfully achieved for all patients. All 3 registration methods gave better quality based on visual inspection, and nonrigid registration gave significantly better results than the other registration methods (p < 0.05). The cost function for three-dimensional registration using nonrigid registration (235.3 +/- 13.9) was significantly better than those of manual and rigid registration (218.5 +/- 15.3 and 223.7 +/- 17.0, respectively). Inter-observer reproducibility error was within acceptable limits for all methods, and there were no significant difference among the methods. CONCLUSION: This technique of image registration may assist the integration of information from gated SPECT and CTCA, and may have clinical application for the diagnosis of ischemic heart disease.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Técnica de Subtração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...