Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(3)2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-32046169

RESUMO

The study proposes an outlier refinement methodology for automatic distortion rectification of wide-angle and fish-eye lens camera models in the context of streamlining vision-based tasks. The line-members sets are estimated in a scene through accumulation of line candidates emerging from the same edge source. An iterative optimization with an outlier refinement scheme was applied to the loss value, to simultaneously remove the extremely curved outliers from the line-members set and update the robust line members as well as estimating the best-fit distortion parameters with lowest possible loss. The proposed algorithm was able to rectify the distortions of wide-angle and fish-eye cameras even in extreme conditions such as heavy illumination changes and severe lens distortions. Experiments were conducted using various evaluation metrics both at the pixel-level (image quality, edge stretching effects, pixel-point error) as well as higher-level use-cases (object detection, height estimation) with respect to real and synthetic data from publicly available, privately acquired sources. The performance evaluations of the proposed algorithm have been investigated using an ablation study on various datasets in correspondence to the significance analysis of the refinement scheme and loss function. Several quantitative and qualitative comparisons were carried out on the proposed approach against various self-calibration approaches.

2.
Sensors (Basel) ; 19(15)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370372

RESUMO

This paper proposes a self-calibration method that can be applied for multiple larger field-of-view (FOV) camera models on an advanced driver-assistance system (ADAS). Firstly, the proposed method performs a series of pre-processing steps such as edge detection, length thresholding, and edge grouping for the segregation of robust line candidates from the pool of initial distortion line segments. A novel straightness cost constraint with a cross-entropy loss was imposed on the selected line candidates, thereby exploiting that novel loss to optimize the lens-distortion parameters using the Levenberg-Marquardt (LM) optimization approach. The best-fit distortion parameters are used for the undistortion of an image frame, thereby employing various high-end vision-based tasks on the distortion-rectified frame. In this study, an investigation was carried out on experimental approaches such as parameter sharing between multiple camera systems and model-specific empirical γ -residual rectification factor. The quantitative comparisons were carried out between the proposed method and traditional OpenCV method as well as contemporary state-of-the-art self-calibration techniques on KITTI dataset with synthetically generated distortion ranges. Famous image consistency metrics such as peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and position error in salient points estimation were employed for the performance evaluations. Finally, for a better performance validation of the proposed system on a real-time ADAS platform, a pragmatic approach of qualitative analysis has been conducted through streamlining high-end vision-based tasks such as object detection, localization, and mapping, and auto-parking on undistorted frames.

3.
Appl Opt ; 57(22): E50-E56, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30117921

RESUMO

The optimum geometry for waveguide propagation was determined by comparing bowtie and semicircle antenna cuts to a standard plain waveguide with a 635 nm laser. The results of both experimental data and COMSOL simulations proved that the bowtie antenna increased waveguide output in comparison to the plain waveguide with the semicircle pattern showing no enhancement. It was also determined that the propagation was highest when the polarization direction of the laser was perpendicular to the direction of the waveguide for all patterns, while polarization along the propagation direction led to little or no output in all antenna and plain waveguide cases. The waveguide output of the bowtie antenna and plain structures was then measured using a tunable laser for wavelengths from 570 nm to 958 nm under both parallel and perpendicular polarization conditions. The results indicated that the bowtie antenna performed better over the entire range with an average increase factor of 2.12±0.40 over the plain waveguide pattern when perpendicularly polarized to the waveguide direction, and 1.10±0.48 when parallel. The measured values indicate that the structure could have applications in broadband devices.

4.
Opt Express ; 25(12): 13145-13152, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28788850

RESUMO

We have experimentally investigated the enhancement in spatial resolution by image subtraction in mid-infrared central solid-immersion lens (c-SIL) microscopy. The subtraction exploits a first image measured with the c-SIL point-spread function (PSF) realized with a Gaussian beam and a second image measured with the beam optically patterned by a silicon π-step phase plate, to realize a centrally hollow PSF. The intense sides lobes in both PSFs that are intrinsic to the SIL make the conventional weighted subtraction methods inadequate. A spatial-domain filter with a kernel optimized to match both experimental PSFs in their periphery was thus developed to modify the first image prior to subtraction, and this resulted in greatly improved performance, with polystyrene beads 1.4 ± 0.1 µm apart optically resolved with a mid-IR wavelength of 3.4 µm in water. Spatial-domain filtering is applicable to other PSF pairs, and simulations show that it also outperforms conventional subtraction methods for the Gaussian and doughnut beams widely used in visible and near-IR microscopy.

5.
Opt Express ; 24(21): 24377-24389, 2016 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-27828167

RESUMO

The spatial resolution in far-field mid-infrared (λ>2.5 µm) microscopy and micro-spectroscopy remains limited with the full-width at half maximum of the point-spread function ca. λ/1.3; a value that is very poor in comparison to that commonly accessible with visible and near-infrared optics. Hereafter, it is demonstrated however that polymer beads that are centre-to-centre spaced by λ/2.6 can be resolved in the mid-infrared. The more than 2-fold improvement in resolution in the far-field is achieved by exploiting a newly constructed scanning microscope built around a mid-infrared optical parametric oscillator and a central solid-immersion lens, and by enforcing the linear polarization unidirectional resolution enhancement with a novel and robust specimen error minimization based on a particle swarm optimization. The method is demonstrated with specimens immersed in air and in water, and its robustness shown by the analysis of dense and complex self-assembled bead islands.

6.
Opt Express ; 21(22): 25632-42, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24216788

RESUMO

Although confocal infrared (IR) absorption micro-spectroscopy is well established for far-field chemical imaging, its scope remains restricted since diffraction limits the spatial resolution to values a little above half the radiation wavelength. Yet, the successful implementations of below-the-diffraction limit far-field fluorescence microscopies using saturated irradiation patterns for example for stimulated-emission depletion and saturated structured-illumination suggest the possibility of using a similar optical patterning strategy for infrared absorption mapping at high resolution. Simulations are used to show that the simple mapping of the difference in transmitted/reflected IR energy between a saturated vortex-shaped beam and a Gaussian reference with a confocal microscope affords the generation of high-resolution vibrational absorption images. On the basis of experimentally relevant parameters, the simulations of the differential absorption scheme reveal a spatial resolution better than a tenth of the wavelength for incident energies about a decade above the saturation threshold. The saturated structured illumination concepts are thus expected to be compatible with the establishment of point-like point-spread functions for measuring the absorbance of samples with a scanning confocal microscope recording the differential transmission/reflection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...