Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 20397, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37989845

RESUMO

Cervical cancer is a leading cause of death for women in low-resource settings despite being preventable through human papillomavirus (HPV) vaccination, early detection, and treatment of precancerous lesions. The World Health Organization recommends high-risk HPV (hrHPV) as the preferred cervical cancer screening strategy, which is difficult to implement in low-resource settings due to high costs, reliance on centralized laboratory infrastructure, and long sample-to-answer times. To help meet the need for rapid, low-cost, and decentralized cervical cancer screening, we developed tailed primer isothermal amplification and lateral flow detection assays for HPV16, HPV18, and HPV45 DNA. We translated these assays into a self-contained cartridge to achieve multiplexed detection of three hrHPV genotypes in a disposable cartridge. The developed test achieves clinically relevant limits of detection of 50-500 copies per reaction with extracted genomic DNA from HPV-positive cells. Finally, we performed sample-to-answer testing with direct lysates of HPV-negative and HPV-positive cell lines and demonstrated consistent detection of HPV16, HPV18, and HPV45 with 5000-50,000 cells/mL in < 35 min. With additional optimization to improve cartridge reliability, incorporation of additional hrHPV types, and validation with clinical samples, the assay could serve as a point-of-care HPV DNA test that improves access to cervical cancer screening in low-resource settings.


Assuntos
Ácidos Nucleicos , Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Papillomavirus Humano 16/genética , Sistemas Automatizados de Assistência Junto ao Leito , Detecção Precoce de Câncer , Infecções por Papillomavirus/diagnóstico , Reprodutibilidade dos Testes , DNA Viral/genética , Genótipo , Papillomaviridae/genética
2.
PLOS Glob Public Health ; 3(8): e0001982, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37585432

RESUMO

The World Health Organization (WHO) has called for the elimination of cervical cancer as a public health problem. Cervical cancer screening through human papillomavirus (HPV) testing is a core component of the strategy for elimination, with a set target of screening 70% of women twice in their lifetimes. In this review, we discuss technical barriers and opportunities to increase HPV screening globally.

3.
Sci Transl Med ; 15(701): eabn4768, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-37343083

RESUMO

High-risk human papillomavirus (HPV) DNA testing is widely acknowledged as the most sensitive cervical cancer screening method but has limited availability in resource-limited settings, where the burden of cervical cancer is highest. Recently, HPV DNA tests have been developed for use in resource-limited settings, but they remain too costly for widespread use and require instruments that are often limited to centralized laboratories. To help meet the global need for low-cost cervical cancer screening, we developed a prototype, sample-to-answer, point-of-care test for HPV16 and HPV18 DNA. Our test relies on isothermal DNA amplification and lateral flow detection, two technologies that reduce the need for complex instrumentation. We integrated all test components into a low-cost, manufacturable platform, and performance of the integrated test was evaluated with synthetic samples, provider-collected clinical samples in a high-resource setting in the United States, and self-collected clinical samples in a low-resource setting in Mozambique. We demonstrated a clinically relevant limit of detection of 1000 HPV16 or HPV18 DNA copies per test. The test requires six user steps, yields results in 45 min, and can be performed using a benchtop instrument and minicentrifuge by minimally trained personnel. The projected per-test cost is <$5, and the projected instrumentation cost is <$1000. These results show the feasibility of a sample-to-answer, point-of-care HPV DNA test. With the inclusion of other HPV types, this test has the potential to fill a critical gap for decentralized and globally accessible cervical cancer screening.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/genética , Infecções por Papillomavirus/diagnóstico , Região de Recursos Limitados , Detecção Precoce de Câncer/métodos , DNA Viral/genética , Técnicas de Amplificação de Ácido Nucleico/métodos
4.
Lab Chip ; 23(3): 451-465, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36562325

RESUMO

Cervical cancer is a leading cause of cancer death for women in low-resource settings. The World Health Organization recommends that cervical cancer screening programs incorporate HPV DNA testing, but available tests are expensive, require laboratory infrastructure, and cannot be performed at the point-of-care. We developed a two-dimensional paper network (2DPN), hybrid-capture, signal amplification assay and a point-of-care sample preparation protocol to detect high-risk HPV DNA from exfoliated cervical cells within an hour. The test does not require expensive equipment and has an estimated cost of <$3 per test without the need for batching. We evaluated performance of the paper HPV DNA assay with short synthetic and genomic HPV DNA targets, HPV positive and negative cellular samples, and two sets of clinical samples. The first set of clinical samples consisted of 16 biobanked, provider-collected cervical samples from a study in El Salvador previously tested with careHPV and subsequently tested in a controlled laboratory environment. The paper HPV DNA test correctly identified eight of eight HPV-negative clinical samples and seven of eight HPV-positive clinical samples. We then performed a field evaluation of the paper HPV DNA test in a hospital laboratory in Mozambique. Cellular controls generated expected results throughout field testing with fully lyophilized sample preparation and 2DPN reagents. When evaluated with 16 residual self-collected cervicovaginal samples previously tested by the GeneXpert HPV assay ("Xpert"), the accuracy of the HPV DNA paper test in the field was reduced compared to testing in the controlled laboratory environment, with positive results obtained for all eight HPV-positive samples as well as seven of eight HPV-negative samples. Further evaluation showed reduction in performance was likely due in part to increased concentration of exfoliated cells in the self-collected clinical samples from Mozambique compared with provider-collected samples from El Salvador. Finally, a formal usability assessment was conducted with users in El Salvador and Mozambique; the assay was rated as acceptable to perform after minimal training. With additional optimization for higher cell concentrations and inclusion of an internal cellular control, the paper HPV DNA assay offers promise as a low-cost, point-of-care cervical cancer screening test in low-resource settings.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/prevenção & controle , Infecções por Papillomavirus/diagnóstico , Detecção Precoce de Câncer/métodos , Interface Usuário-Computador , Papillomaviridae/genética , DNA
5.
PLoS One ; 17(2): e0264130, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35213596

RESUMO

The global COVID-19 pandemic has highlighted the need for rapid, accurate and accessible nucleic acid tests to enable timely identification of infected individuals. We optimized a sample-to-answer nucleic acid test for SARS-CoV-2 that provides results in <1 hour using inexpensive and readily available reagents. The test workflow includes a simple lysis and viral inactivation protocol followed by direct isothermal amplification of viral RNA using RT-LAMP. The assay was validated using two different instruments, a portable isothermal fluorimeter and a standard thermocycler. Results of the RT-LAMP assay were compared to traditional RT-qPCR for nasopharyngeal swabs, nasal swabs, and saliva collected from a cohort of patients hospitalized due to COVID-19. For all three sample types, positive agreement with RT-LAMP performed using the isothermal fluorimeter was 100% for samples with Ct <30 and 69-91% for samples with Ct <40. Following validation, the test was successfully scaled to test the saliva of up to 400 asymptomatic individuals per day as part of the campus surveillance program at Rice University. Successful development, validation, and scaling of this sample-to-answer, extraction-free real-time RT-LAMP test for SARS-CoV-2 adds a highly adaptable tool to efforts to control the COVID-19 pandemic, and can inform test development strategies for future infectious disease threats.


Assuntos
Teste para COVID-19 , COVID-19/diagnóstico , Nasofaringe/virologia , Nariz/virologia , Vigilância da População/métodos , SARS-CoV-2/isolamento & purificação , Saliva/virologia , COVID-19/virologia , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , Sensibilidade e Especificidade
6.
Trends Cancer ; 8(4): 295-302, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35181273

RESUMO

Precision cancer prevention as it is currently envisioned is a targeted, molecular-based approach to intercept carcinogenesis before cancer develops or before it becomes untreatable. Unfortunately, due to systemic biases, current precision cancer prevention interventions might not be effective in all populations, especially in minoritized communities. In addition, not all cancer risk is attributable to genetic or even biological factors, but includes social determinants of health (SDH). Here, we propose a broader framework for precision cancer prevention, anchored in optimizing the benefits to harms for all people. We propose that precision cancer prevention considers not only what is being delivered, but also for whom, where, and how, with a goal of achieving cancer prevention health equity.


Assuntos
Equidade em Saúde , Neoplasias , Promoção da Saúde , Disparidades nos Níveis de Saúde , Humanos , Neoplasias/genética , Neoplasias/prevenção & controle , Determinantes Sociais da Saúde
7.
Anal Chem ; 93(11): 4832-4840, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33689292

RESUMO

Sickle cell disease (SCD) is a group of common, life-threatening disorders caused by a point mutation in the ß globin gene. Early diagnosis through newborn and early childhood screening, parental education, and preventive treatments are known to reduce mortality. However, the cost and complexity of conventional diagnostic methods limit the feasibility of early diagnosis for SCD in resource-limited areas worldwide. Although several point-of-care tests are commercially available, most are antibody-based tests, which cannot be used in patients who have recently received a blood transfusion. Here, we describe the development of a rapid, low-cost nucleic acid test that uses real-time fluorescence to detect the point mutation encoding hemoglobin S (HbS) in one round of isothermal recombinase polymerase amplification (RPA). When tested with a set of clinical samples from SCD patients and healthy volunteers, our assay demonstrated 100% sensitivity for both the ßA globin and ßS globin alleles and 94.7 and 97.1% specificities for the ßA globin allele and ßS globin allele, respectively (n = 91). Finally, we demonstrate proof-of-concept sample-to-answer genotyping of genomic DNA from capillary blood using an alkaline lysis procedure and direct input of diluted lysate into RPA. The workflow is performed in <30 min at a cost of <$5 USD on a commercially available benchtop fluorimeter and an open-source miniature fluorimeter. This study demonstrates the potential utility of a rapid, sample-to-answer nucleic acid test for SCD that may be implemented near the point of care and could be adapted to other disease-causing point mutations in genomic DNA.


Assuntos
Anemia Falciforme , Recombinases , Alelos , Anemia Falciforme/diagnóstico , Anemia Falciforme/genética , Pré-Escolar , Hemoglobina Falciforme/análise , Humanos , Recém-Nascido , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
8.
J Biomol Tech ; 32(3): 180-185, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-35027875

RESUMO

Frequent and accessible testing is a critical tool to contain the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To develop low-cost rapid tests, many researchers have used reverse transcription loop-mediated isothermal amplification (RT-LAMP) with fluorescent readout. Fluorescent LAMP-based assays can be performed using cost-effective, portable, isothermal instruments that are simpler to use and more rugged than polymerase chain reaction (PCR) instruments. However, false-positive results due to nonspecific priming and amplification have been reported for a number of LAMP-based assays. In this report, we implemented a RT-LAMP assay for SARS-CoV-2 on a portable isothermal fluorimeter and a traditional thermocycler; nonspecific amplification was not observed using the thermocycler but did occur frequently with the isothermal fluorimeter. We explored 4 strategies to optimize the SARS-CoV-2 RT-LAMP assay for use with an isothermal fluorimeter and found that overlaying the reaction with mineral oil and including the enzyme Tte UvrD helicase in the reaction eliminated the problem. We anticipate these results and strategies will be relevant for use with a wide range of portable isothermal instruments.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/genética , Sensibilidade e Especificidade
9.
Expert Rev Mol Diagn ; 19(8): 695-714, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31368827

RESUMO

Introduction: Cervical cancer mortality rates remain high in low- and middle-income countries (LMICs) and other medically underserved areas due to challenges with implementation and sustainability of routine screening, accurate diagnosis, and early treatment of preinvasive lesions. Areas covered: In this review, we first discuss the standard of care for cervical cancer screening and diagnosis in high- and low-resource settings, biomarkers that correlate to cervical precancer and cancer, and needs for new tests. We review technologies for screening and diagnosis with a focus on tests that are already in use in LMICs or have the potential to be adapted for use in LMICs. Finally, we provide perspectives on the next five years of technology development for improved cervical cancer screening and diagnosis in LMICs. Expert opinion: Innovation toward improved molecular and imaging tests is needed to enable effective, affordable see-and-treat approaches to detect and treat cervical precancer in a single visit. Current molecular tests remain too complex and/or costly for widespread use. Especially with imaging tests, decision support may improve performance of new technologies.


Assuntos
Biomarcadores/análise , Programas de Rastreamento/métodos , Neoplasias do Colo do Útero/diagnóstico , Detecção Precoce de Câncer , Feminino , Recursos em Saúde , Humanos , Testes Imediatos , Sensibilidade e Especificidade
10.
Lab Chip ; 17(20): 3351-3387, 2017 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-28832061

RESUMO

Each day, approximately 830 women and 7400 newborns die from complications during pregnancy and childbirth. Improving maternal and neonatal health will require bringing rapid diagnosis and treatment to the point of care in low-resource settings. However, to date there are few diagnostic tools available that can be used at the point of care to detect the leading causes of maternal and neonatal mortality in low-resource settings. Here we review both commercially available diagnostics and technologies that are currently in development to detect the leading causes of maternal and neonatal mortality, highlighting key gaps in development where innovative design could increase access to technology and enable rapid diagnosis at the bedside.


Assuntos
Saúde do Lactente , Saúde Materna , Sistemas Automatizados de Assistência Junto ao Leito , Redução de Custos , Desenho de Equipamento , Feminino , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Gravidez , Diagnóstico Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...