1.
Diabetes Technol Ther ; 11(2): 93-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19848575

RESUMO

BACKGROUND: Nocturnal hypoglycemia is a significant problem. From 50% to 75% of hypoglycemia seizures occur at night. Despite the development of real-time glucose sensors (real-time continuous glucose monitor [CGM]) with hypoglycemic alarms, many patients sleep through these alarms. The goal of this pilot study was to assess the feasibility using a real-time CGM to discontinue insulin pump therapy when hypoglycemia was predicted. METHODS: Twenty-two subjects with type 1 diabetes had two daytime admissions to a clinical research center. On the first admission their basal insulin was increased until their blood glucose level was <60 mg/dL. On the second admission hypoglycemic prediction algorithms were tested to determine if hypoglycemia was prevented by a 90-min pump shutoff and to determine if the pump shutoff resulted in rebound hyperglycemia. RESULTS: Using a statistical prediction algorithm with an 80 mg/dL threshold and a 30-min projection horizon, hypoglycemia was prevented 60% of the time. Using a linear prediction algorithm with an 80 mg/dL threshold and a 45-min prediction horizon, hypoglycemia was prevented 80% of the time. There was no rebound hyperglycemia following pump suspension. CONCLUSIONS: Further development of algorithms is needed to prevent all episodes of hypoglycemia from occurring.


Assuntos
Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina/estatística & dados numéricos , Algoritmos , Glicemia/metabolismo , Diabetes Mellitus/sangue , Diabetes Mellitus/tratamento farmacológico , Implantes de Medicamento , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Monitorização Fisiológica/métodos
2.
Diabetes Care ; 28(1): 15-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15616227

RESUMO

OBJECTIVE: Our goals were to determine if continuous subcutaneous insulin infusion (CSII), compared with those continuing multiple daily injections (MDIs), can be safely used in young children, if those on CSII will have superior glycemic control, if subjects using CSII will have less hypoglycemia for their level of control, and if families using CSII will report an improved quality of life. RESEARCH DESIGN AND METHODS: We conducted a randomized 1-year feasibility trial comparing CSII with continuing MDIs in preschool children with a history of type 1 diabetes for at least 6 months' duration. Prospective outcomes included measures of overall glycemic control (HbA1c and continuous glucose monitoring system), the incidence of severe hypoglycemia and diabetic ketoacidosis, the percent of glucose values below 3.9 mmol/l, and the parents' report of quality of life. RESULTS: The 19 subjects' ages ranged from 1.7 to 6.1 (mean 3.6) years, duration of diabetes ranged from 0.6 to 2.6 (mean 1.4) years, and baseline HbA1c ranged from 6.7 to 9.6% (mean 7.9%). Seven subjects were male. Nine subjects were randomized to start CSII and 10 to continue on MDI. All baseline characteristics were well balanced. Overall metabolic control, diabetes quality of life, and the incidence of hypoglycemia were similar in the two groups. No subject had diabetic ketoacidosis, while one subject in each group had an episode of severe hypoglycemia. No CSII subject discontinued using the pump during or after the study. CONCLUSIONS: CSII can be a safe and effective method to deliver insulin in young children.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Sistemas de Infusão de Insulina , Glicemia/efeitos dos fármacos , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/sangue , Estudos de Viabilidade , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/prevenção & controle , Lactente , Monitorização Ambulatorial , Reprodutibilidade dos Testes , Resultado do Tratamento