Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Phys Rev Lett ; 120(26): 263003, 2018 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-30004781

RESUMO

One of the most important atomic properties governing an element's chemical behavior is the energy required to remove its least-bound electron, referred to as the first ionization potential. For the heaviest elements, this fundamental quantity is strongly influenced by relativistic effects which lead to unique chemical properties. Laser spectroscopy on an atom-at-a-time scale was developed and applied to probe the optical spectrum of neutral nobelium near the ionization threshold. The first ionization potential of nobelium is determined here with a very high precision from the convergence of measured Rydberg series to be 6.626 21±0.000 05 eV. This work provides a stringent benchmark for state-of-the-art many-body atomic modeling that considers relativistic and quantum electrodynamic effects and paves the way for high-precision measurements of atomic properties of elements only available from heavy-ion accelerator facilities.

2.
Phys Rev Lett ; 120(23): 232503, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29932712

RESUMO

Until recently, ground-state nuclear moments of the heaviest nuclei could only be inferred from nuclear spectroscopy, where model assumptions are required. Laser spectroscopy in combination with modern atomic structure calculations is now able to probe these moments directly, in a comprehensive and nuclear-model-independent way. Here we report on unique access to the differential mean-square charge radii of ^{252,253,254}No, and therefore to changes in nuclear size and shape. State-of-the-art nuclear density functional calculations describe well the changes in nuclear charge radii in the region of the heavy actinides, indicating an appreciable central depression in the deformed proton density distribution in ^{252,254}No isotopes. Finally, the hyperfine splitting of ^{253}No was evaluated, enabling a complementary measure of its (quadrupole) deformation, as well as an insight into the neutron single-particle wave function via the nuclear spin and magnetic moment.

3.
Phys Med Biol ; 63(4): 045025, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29466250

RESUMO

The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suitable for external detection. In this publication we demonstrate the theranostic abilities of the 211At/209At isotope pair and present the first-ever 209At SPECT images. The VECTor microSPECT/PET/CT scanner was used to image 209At with a collimator suitable for the 511 keV annihilation photons of PET isotopes. Data from distinct photopeaks of the 209At energy spectrum (195 keV (22.6%), 239 keV (12.4 %), 545 keV (91.0 %), a combined 782/790 keV peak (147 %), and 209Po x-rays (139.0 %)) were independently evaluated for use in image reconstructions using Monte Carlo (GATE) simulations and phantom studies. 209At-imaging in vivo was demonstrated in a healthy mouse injected with 10 MBq of free [209At]astatide. Image-based measurements of 209At uptake in organs of interest-acquired in 5 min intervals-were compared to ex vivo gamma counter measurements of the same organs. Simulated and measured data indicated that-due to the large amount of scatter from high energy (>750 keV) gammas-reconstructed images using the x-ray peak outperformed those obtained from other peaks in terms of image uniformity and spatial resolution, determined to be <0.85 mm. 209At imaging using the x-ray peak revealed a biodistribution that matched the known distribution of free astatide, and in vivo image-based measurements of 209At uptake in organs of interest matched ex vivo measurements within 10%. We have acquired the first 209At SPECT images and demonstrated the ability of quantitative SPECT imaging with 209At to accurately determine astatine biodistributions with high spatial and temporal resolution.


Assuntos
Astato/metabolismo , Método de Monte Carlo , Imagens de Fantasmas , Compostos Radiofarmacêuticos/metabolismo , Nanomedicina Teranóstica/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Humanos , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos C57BL , Distribuição Tecidual
4.
Endocr Relat Cancer ; 22(1): 1-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25376618

RESUMO

Pasireotide long-acting repeatable (LAR) is a novel somatostatin analog (SSA) with avid binding affinity to somatostatin receptor subtypes 1, 2, 3 (SSTR1,2,3) and 5 (SSTR5). Results from preclinical studies indicate that pasireotide can inhibit neuroendocrine tumor (NET) growth more robustly than octreotide in vitro. This open-label, phase II study assessed the clinical activity of pasireotide in treatment-naïve patients with metastatic grade 1 or 2 NETs. Patients with metastatic pancreatic and extra-pancreatic NETs were treated with pasireotide LAR (60 mg every 4 weeks). Previous systemic therapy, including octreotide and lanreotide, was not permitted. Tumor assessments were performed every 3 months using Response Evaluation Criteria in Solid Tumors (RECIST) criteria. The primary endpoint was progression-free survival (PFS). The secondary endpoints included overall survival (OS), overall radiographic response rate (ORR), and safety. Twenty-nine patients were treated with pasireotide LAR (60 mg every 4 weeks) and 28 were evaluable for response. The median PFS was 11 months. The most favorable effect was observed in patients with low hepatic tumor burden, normal baseline chromogranin A, and high tumoral SSTR5 expression. Median OS has not been reached; the 30-month OS rate was 70%. The best radiographic response was partial response in one patient (4%), stable disease in 17 patients (60%), and progressive disease in ten patients (36%). Although grade 3/4 toxicities were rare, pasireotide LAR treatment was associated with a 79% rate of hyperglycemia including 14% grade 3 hyperglycemia. Although pasireotide appears to be an effective antiproliferative agent in the treatment of advanced NETs, the high incidence of hyperglycemia raises concerns regarding its suitability as a first-line systemic agent in unselected patients. SSTR5 expression is a potentially predictive biomarker for response.


Assuntos
Tumores Neuroendócrinos/tratamento farmacológico , Neoplasias Pancreáticas/tratamento farmacológico , Somatostatina/análogos & derivados , Adulto , Idoso , Preparações de Ação Retardada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Tumores Neuroendócrinos/metabolismo , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Receptores de Somatostatina/metabolismo , Somatostatina/administração & dosagem
5.
Rev Sci Instrum ; 85(2): 02B912, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593617

RESUMO

At the ISAC facility at TRIUMF radioactive ions are produced by bombarding solid targets with up to 100 µA of 500 MeV protons. The reaction products have to diffuse out of the hot target into an ion source. Normally, singly charged ions are extracted. They can be transported either directly to experiments or via an ECR charge state breeder to a post accelerator. Several different types of ion sources have to be used in order to deliver a large variety of rare isotope beams. At ISAC those are surface ion sources, forced electron beam arc discharge (FEBIAD) ion sources and resonant laser ionization sources. Recent development activities concentrated on increasing the selectivity for the ionization to suppress isobaric contamination in the beam. Therefore, a surface ion rejecting resonant laser ionization source (SIRLIS) has been developed to suppress ions from surface ionization. For the FEBIAD ion source a cold transfer line has been introduced to prevent less volatile components from reaching the ion source.

6.
Med Phys ; 40(11): 111710, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24320418

RESUMO

PURPOSE: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed. METHODS: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between -4 and +4 cm for the translational axes and between -3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system. RESULTS: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were -0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03° ± 0.06°, -0.04° ± 0.12°, and -0.01° ± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg. CONCLUSIONS: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.


Assuntos
Radioterapia/instrumentação , Radioterapia/métodos , Tomografia Computadorizada de Feixe Cônico , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Posicionamento do Paciente , Imagens de Fantasmas , Controle de Qualidade , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Reprodutibilidade dos Testes , Rotação
7.
J Dairy Sci ; 96(8): 5352-63, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23769375

RESUMO

The first objective of this study was to compare the productive and reproductive performance of Holstein-Friesian (CH HF), Fleckvieh (CH FV), and Brown Swiss (CH BS) cows of Swiss origin with New Zealand Holstein-Friesian (NZ HF) cows in pasture-based compact-calving systems; NZ HF cows were chosen as the reference population for such grazing systems. The second objective was to analyze the relationships within and between breeds regarding reproductive performance, milk yield, and body condition score (BCS) dynamics. On 15 commercial Swiss farms, NZ HF cows were paired with Swiss cows over 3 yr. Overall, the study involved 259 complete lactations from 134 cows: 131 from 58 NZ HF, 40 from 24 CH HF, 43 from 27 CH FV, and 45 from 25 CH BS cows. All production parameters were affected by cow breed. Milk and energy-corrected milk yield over 270 d of lactation differed by 1,000 kg between the 2 extreme groups; CH HF having the highest yield and CH BS the lowest. The NZ HF cows had the greatest milk fat and protein concentrations over the lactation and exhibited the highest lactation persistency. Body weight differed by 90 kg between extreme groups; NZ HF and CH BS being the lightest and CH HF and CH FV the heaviest. As a result, the 2 HF strains achieved the highest milk production efficiency (270-d energy-corrected milk/body weight(0.75)). Although less efficient at milk production, CH FV had a high 21-d submission rate (86%) and a high conception rate within 2 inseminations (89%), achieving high pregnancy rates within the first 3 and 6 wk of the breeding period (65 and 81%, respectively). Conversely, poorer reproductive performance was recorded for CH HF cows, with NZ HF and CH BS being intermediate. Both BCS at nadir and at 100 d postpartum had a positive effect on the 6-wk pregnancy rate, even when breed was included in the model. The BCS at 100 d of lactation also positively affected first service conception rate. In conclusion, despite their high milk production efficiency, even in low-input systems, CH HF were not suited to pasture-based seasonal-calving production systems due to poor reproductive performance. On the contrary, CH FV fulfilled the compact-calving reproduction objectives and deserve further consideration in seasonal calving systems, despite their lower milk production potential.


Assuntos
Constituição Corporal/fisiologia , Bovinos/fisiologia , Indústria de Laticínios/métodos , Lactação/fisiologia , Animais , Constituição Corporal/genética , Peso Corporal , Bovinos/genética , Gorduras/análise , Feminino , Lactação/genética , Leite/química , Proteínas do Leite/análise , Gravidez , Especificidade da Espécie
8.
J Anim Physiol Anim Nutr (Berl) ; 95(6): 717-29, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21114551

RESUMO

This study compared productivity of dairy cows with different body weight (BW), but a constant ratio of maintenance to production requirements in their first lactation, in a pasture-based production system with spring calving. Two herds, Herd L (13 and 14 large cows in 2003 and 2004 respectively; average BW after calving, 721 kg) and Herd S (16 small cows in both years; 606 kg) [Correction added after online publication 14 January 2011: 16 small cows in both years; 621 kg was changed to 16 small cows in both years; 606 kg], all in their second or following lactations, were each allocated 6 ha of pasture and rotationally grazed on 10 parallel paddocks with equal herbage offer and nutritional values. Winter hay, harvested from the same pastures, was offered ad libitum in the indoor periods in a tied stall barn. Each herd received, per lactation and year, approximately 2000 kg dry matter (DM) of concentrates and of fodder beets, equally distributed to every individual. Indoors, the L-cows ingested more DM than the S-cows (18.7 vs. 16.3 kg DM/cow per day; p < 0.01), but DM intake per 100 kg of metabolic BW was similar (13.0 vs. 13.1 kg DM/cow per day). Estimates based on the n-alkane technique gave similar results on pasture (17.9 vs. 15.5 kg DM/cow per day; p < 0.001). Roughage intakes per 100 kg of metabolic BW, at 13.5 kg DM/cow per day, were similar. Mean annual yield of energy-corrected milk (ECM)/ha was slightly higher for the S-herd than the L-herd (13,026 vs. 12,284 kg) but was associated with a higher stocking rate (on average +20%) for the S-herd. Feed conversion efficiency (1.2 vs. 1.3 kg ECM/kg DM intake) and overall milk production efficiency (45.3 vs. 47.3 kg ECM/kg metabolic BW) were similar in L- and S-cows. Thus, both dairy cow types were equally efficient in utilising pasture-based forage.


Assuntos
Criação de Animais Domésticos/métodos , Peso Corporal/fisiologia , Bovinos/fisiologia , Lactação/fisiologia , Ração Animal/análise , Fenômenos Fisiológicos da Nutrição Animal , Animais , Dieta/veterinária , Feminino , Fertilidade , Estações do Ano , Tempo
9.
Dis Esophagus ; 23(4): 300-8, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19732129

RESUMO

The objective of this study is to determine the feasibility and report the outcome of patients with locally advanced esophageal cancer treated with preoperative or definitive chemoradiotherapy (CRT) using intensity-modulated radiation therapy (IMRT). Between 2003 and 2007, 30 patients with non-cervical esophageal cancer received concurrent chemotherapy and IMRT at Stanford University. Eighteen patients were planned for definitive CRT and 12 were planned for preoperative CRT. All patients had computed tomography-based treatment planning and received IMRT. The median dose delivered was 50.4 Gy. Patients planned for preoperative CRT underwent surgery 4-13 weeks (median 8.3 weeks) following completion of CRT. Median follow-up of surviving patients from start of RT was 24.2 months (range 8.2-38.3 months). The majority of tumors were adenocarcinomas (67%) and poorly differentiated (57%). Tumor location was 7% upper, 20% mid, 47% lower, and 27% gastroesophageal junction. Actuarial 2-year local-regional control (LRC) was 64%. High tumor grade was an adverse prognostic factor for LRC and overall survival (OS) (P= 0.015 and 0.012, respectively). The 2-year LRC was 83% vs. 51% for patients treated preoperatively vs. definitively (P= 0.32). The 2-year disease-free and OS were 38% and 56%, respectively. Twelve patients (40%) required feeding tube placement, and the average weight loss from baseline was 4.8%. Twelve (40%) patients experienced grade 3+ acute complications and one patient died of complications following feeding tube placement. Three patients (10%) required a treatment break. Eight patients (27%) experienced grade 3 late complications. No grade 4 complications were seen. IMRT was effective and well tolerated. Disease recurrence remains a challenge and further investigation with dose escalation to improve LRC and OS is warranted.


Assuntos
Adenocarcinoma/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Esofágicas/radioterapia , Radioterapia de Intensidade Modulada , Adenocarcinoma/tratamento farmacológico , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/cirurgia , Terapia Combinada , Neoplasias Esofágicas/tratamento farmacológico , Neoplasias Esofágicas/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Doses de Radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
10.
Colorectal Dis ; 12(7 Online): e24-30, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19614668

RESUMO

OBJECTIVE: The aim of this study was to investigate the effect of preoperative chemoradiotherapy (CRT) on nodal disease in locally advanced rectal adenocarcinoma. METHOD: Thirty-two patients staged uT3N0 and 27 patients staged uT3N1 rectal adenocarcinoma who underwent pre-CRT staging using endoscopic ultrasound or rectal protocol CT were included. The median radiation dose was 50.4 Gy (range: 45-50.4 Gy) at 1.8 Gy per fraction and all patients received concurrent 5-FU or capecitabine-based chemotherapy. Low anterior resection or abdomino-perineal resection occurred at a median of 46 days (range: 27-112 days) after CRT. RESULTS: Eleven of 32 uT3N0 patients (34.4%) and 13 of 26 uT3N1 patients (50.0%) had ypN+ (P = 0.29). For patients with uT3N0, 10 of 20 (50.0%) with ypT2-3 and 1 of 12 (8.3%) with ypT0-1 were ypN+ (P = 0.02). For patients with uT3N1, 12 of 20 (60.0%) with ypT2-3 and 1 of 6 (16.7%) with ypT0-1 were ypN+ (P = 0.16). Overall, the ypN+ rate was 11.1% in the ypT0-yT1 group compared with 55.0% in the ypT2-yT3 group (P = 003). Among patients with uT3N0 disease, the ypN+ rate in patients who had surgery > 46 days vs 46 days vs 46 days vs

Assuntos
Adenocarcinoma/diagnóstico , Antineoplásicos/uso terapêutico , Endossonografia/métodos , Estadiamento de Neoplasias , Neoplasias Retais/diagnóstico , Reto/patologia , Adenocarcinoma/tratamento farmacológico , Adenocarcinoma/radioterapia , Colonoscopia/métodos , Relação Dose-Resposta à Radiação , Seguimentos , Humanos , Neoplasias Retais/tratamento farmacológico , Neoplasias Retais/radioterapia , Reto/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
11.
Eur Surg Res ; 43(1): 13-23, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19365131

RESUMO

BACKGROUND/AIMS: Clinical differentiation between infarcted and viable myocardium in the ischemic area at risk is controversial. We investigated the potential of contrast-enhanced cardiac magnetic resonance imaging (ceCMRI) in determining the area at risk 24 h after ischemia. METHODS: Myocardial ischemia was induced by percutaneous coronary intervention of the left anterior descending coronary artery in pigs. Coronary occlusion time was 30 min in group A, which caused little myocardial infarction and 45 min in group B, which led to irreversible damage. 24 h after reperfusion ceCMRI was performed at 2 and 15 min after administration of gadolinium-diethylenetriamine pentaacetic acid. The area at risk was determined by intravenous injection of Evans blue and myocardial viability by triphenyltetrazolium-chloride staining. RESULTS: The signal-intense areas at 2 and 15 min after contrast administration matched the area at risk in groups A and B. Nonviable myocardium in group A was overestimated (14-15%) while good agreement was present in group B. CONCLUSION: The area at risk of reperfused ischemic myocardium can be determined by ceCMRI 24 h after coronary recanalization. This type of information might have relevant clinical implications in the treatment and stratification of patients with acute coronary syndrome in particular after surgical interventions.


Assuntos
Imageamento por Ressonância Magnética , Traumatismo por Reperfusão Miocárdica/patologia , Miocárdio/patologia , Animais , Sobrevivência Celular , Angiografia Coronária , Feminino , Gadolínio DTPA , Masculino , Necrose , Suínos , Sobrevivência de Tecidos
12.
J Pathol ; 216(2): 158-66, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18702172

RESUMO

Phenotypic and molecular parallels between the development of chondrosarcoma and the differentiation of chondrocytes in normal growth plate suggest that chondrosarcoma may arise from mesenchymal precursor cells driven towards chondrogenesis. We hypothesized that a comparison between cartilaginous tumours and their possible physiological cells of origin, mesenchymal stem cells (MSCs), might have biological and clinical relevance. MSCs from eight donors were submitted to chondrogenic differentiation in spheroid cultures. Expression profiles of MSCs at days 0, 7, 14, 28 and 42 of chondrogenesis and of 18 chondrosarcomas with different histological grades were studied using a customized cDNA array. Hierarchical clustering of MSC gene expression during chondrogenesis allowed the classification of samples in a pre-chondrogenic and a chondrogenic cluster corresponding to the phenotypes of early and late differentiation stages. The 74 genes differentially expressed between the two clusters were defined as chondrogenesis-relevant genes. Gene expression profiles of chondrosarcoma were submitted to hierarchical clustering on the basis of these chondrogenesis-relevant genes. This analysis allowed clear distinction between grade I and grade III chondrosarcoma and separated grade II chondrosarcoma into two groups. All grade II chondrosarcomas with occurrence of metastasis were found together with the grade III chondrosarcomas in the pre-chondrogenic cluster. This analysis shows that a molecular approach based on the comparison of tumour samples to an in vitro model for chondrogenic differentiation allows a new classification of chondrosarcoma in two clusters. These data suggest that the identification of a pre-chondrogenic and a chondrogenic phenotype for chondrosarcoma by gene expression profiling could develop into a useful tool to predict the clinical behaviour of chondrosarcoma.


Assuntos
Condrogênese/genética , Condrossarcoma/genética , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Células-Tronco Mesenquimais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Diferenciação Celular , Linhagem Celular Tumoral , Análise por Conglomerados , Feminino , Expressão Gênica , Marcadores Genéticos , Humanos , Masculino , Análise em Microsséries , Pessoa de Meia-Idade
13.
Phys Med Biol ; 53(6): 1751-71, 2008 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-18367801

RESUMO

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit anatomic knowledge using standard image processing operations. The presented version of algorithms automatically segments the body outline and bones in any gender and patient position, the prostate, bladder and femoral heads for male pelvis in supine position, and the spinal canal, lungs, heart and trachea in supine position. The software was developed and tested on a collection of over 600 clinical radiotherapy planning CT stacks. In a qualitative validation on this test collection, anatomic orientation correctly detected gender, patient position and body region in 98% of the cases, a correct mapping was produced for 89% of thorax and 94% of pelvis cases. The average processing time for the entire segmentation of a CT stack was less than 1 min on a standard personal computer. Two independent retrospective studies were carried out for clinical validation. Study I was performed on 66 cases (30 pelvis, 36 thorax) with dosimetrists, study II on 52 cases (39 pelvis, 13 thorax) with radio-oncologists as experts. The experts rated the automatically produced structures on the scale 1-excellent (no corrections necessary, maximum time saving), 2-good (corrections necessary for up to 1/3 of slices), 3-acceptable (major corrections necessary, but still time saving), 4-not acceptable (manual redrawing more efficient, no time saving). A rating

Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pelve/anatomia & histologia , Pelve/diagnóstico por imagem , Radiografia Torácica , Planejamento da Radioterapia Assistida por Computador/métodos , Tórax/anatomia & histologia , Tomografia Computadorizada por Raios X , Humanos , Masculino , Especificidade de Órgãos , Reprodutibilidade dos Testes , Software , Fatores de Tempo
14.
Phys Rev Lett ; 98(11): 112502, 2007 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-17501046

RESUMO

The shape of exotic even-mass (182-190)Pb isotopes was probed by measurement of optical isotope shifts providing mean square charge radii (delta(r(2))). The experiment was carried out at the isolde (cern) on-line mass separator, using in-source laser spectroscopy. Small deviations from the spherical droplet model are observed, but when compared to model calculations, those are explained by high sensitivity of delta(r(2)) to beyond mean-field correlations and small admixtures of intruder configurations in the ground state. The data support the predominantly spherical shape of the ground state of the proton-magic Z=82 lead isotopes near neutron midshell (N=104).

15.
Eur Radiol ; 15(2): 312-8, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15565315

RESUMO

The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4+/-54.6 ml) and end-systolic (79.1+/-37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9+/-53.7 ml (r=0.98) and 75.0+/-36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2+/-20.2 ml for MPR-CT, 76.9+/-20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8+/-8.4% for MPR-CT, 51.9+/-7.4% for MRI, r=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogeneities of RV contrast enhancement.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Função Ventricular Direita/fisiologia , Idoso , Meios de Contraste , Feminino , Frequência Cardíaca/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas
16.
Rofo ; 176(12): 1786-93, 2004 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-15573290

RESUMO

PURPOSE: To determine global and regional left ventricular (LV) function from retrospectively gated multidetector row computed tomography (CT) by using two different semiautomated analysis tools and to correlate the results with those of magnetic resonance imaging (MRI). MATERIALS AND METHODS: Nineteen patients (5 females, 14 males, mean age 69 years) underwent 16-slice spiral-CT (MS-CT) with standard technique without administration of beta-blockers for a decrease in the cardiac rate. Ten series of images were reconstructed at every 10 % of the RR-interval. With commercially available software capable of semiautomated contour detection, end-diastolic and end-systolic LV volumes (EDV and ESV) were determined from short-axis multiplanar CT reformations (MPR). Axial images of the end-systolic and end-diastolic cardiac phase were transformed to 3D volumes (3D) to determine EDV and ESV by using a threshold-supported reconstruction algorithm dependent on the contrast enhancement of the left ventricle. Steady-state free-precession cine MR images were acquired in short-axis orientation on the same day in all but one patient. Regional wall motion was assessed qualitatively in 17 left ventricular segments and classified as normo-, hypo-, a- or dyskinetic. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MRI. RESULTS: For MPR/3D, mean end-diastolic (144.4/142.8 mL +/- 67.5/67.1) and end-systolic (66.4/68.7 mL +/- 52.1/49.9) LV volumes as determined with MS-CT correlated well with MRI measurements (147.6 mL +/- 67.6 [ r = 0.98/0.96] and 73.3 mL +/- 55.5 [ r = 0.98/0.98], respectively [ p <.001]). LV stroke volume (77.6/74.1 +/- 19.2/23.4 mL for CT vs. 74.4 mL +/- 18.4 for MRI, r = 0.92/0.74) and LV ejection fraction (58.6/55.9 % +/- 13.5/13.7 for CT vs. 55.6 % +/- 13.5 for MRI, r = 0.95/0.91) also showed good correlation (p <.001). Regional wall motion analysis revealed agreement between CT and MRI in 316/323 (97.8 %) myocardial segments. CONCLUSION: Semiautomated analysis of 16-detector row CT data sets enables global and regional volumetric and functional analysis. The CT results correlate well with MRI findings for short axis MPR and for 3D volume reconstructions, with a higher statistical spread for the 3D method. The underestimation of end-systolic and end-diastolic volumes with CT may be caused by partial volume averaging due to the lower temporal resolution as compared with MRI.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada Espiral/métodos , Função Ventricular Esquerda/fisiologia , Idoso , Meios de Contraste , Angiografia Coronária , Doença das Coronárias/cirurgia , Interpretação Estatística de Dados , Diástole , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Software , Volume Sistólico , Sístole
17.
Heart ; 90(6): 678-84, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15145879

RESUMO

OBJECTIVE: To assess with magnetic resonance imaging (MRI) cardiovascular function in response to exercise in patients after atrial correction of transposition of the great arteries (TGA). METHODS: Cardiac function at rest and during submaximal exercise was assessed with MRI in 27 patients with TGA (mean (SD) age 26 (5) years) late (23 (2) years) after atrial correction and in 14 control participants (25 (5) years old). RESULTS: At rest, only right ventricular ejection fraction was significantly lower in patients than in controls (56 (7)% v 65 (7)%, p < 0.05). In response to exercise, increases in right ventricular end diastolic (155 (55) ml to 163 (57) ml, p < 0.05) and right ventricular end systolic volumes (70 (34) ml to 75 (36) ml, p < 0.05) were observed in patients. Furthermore, right and left ventricular stroke volumes and ejection fraction did not increase significantly in patients. Changes in right ventricular ejection fraction with exercise correlated with diminished exercise capacity (r = 0.43, p < 0.05). CONCLUSIONS: In patients with atrially corrected TGA, MRI showed an abnormal response to exercise of both systemic right and left ventricles. Exercise MRI provides a tool for close monitoring of cardiovascular function in these patients, who are at risk for late death.


Assuntos
Exercício Físico/fisiologia , Angiografia por Ressonância Magnética/métodos , Transposição dos Grandes Vasos/fisiopatologia , Função Ventricular/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Teste de Esforço , Feminino , Átrios do Coração/cirurgia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Transposição dos Grandes Vasos/cirurgia , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
18.
Rofo ; 176(4): 605-9, 2004 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-15088188

RESUMO

PURPOSE: Comparison of two different types of contrast-enhanced 3D-MR angiography (CE-MRA) with integrated parallel acquisition technique (iPAT) in patients with chronic-thromboembolic pulmonary hypertension (CTEPH) and evaluation whether sagittal acquisition with higher resolution and minimized acquisition time is superior to common coronal orientation. MATERIALS AND METHODS: CE-MRA was performed on 15 patients with CTEPH preoperatively and on 10 patients also postoperatively, while 5 other patients received only a postoperative MRA. All 30 MR studies with one coronal and two sagittal acquisitions were blindly evaluated and compared. The resolution of coronal and sagittal MRA was 1.3 x 0.6 x 1.4 mm (3) and 1.2 x 1.2 x 1.2 mm (3), and acquisition time 20 and 17 sec (iPAT factor 2, GRAPPA), respectively. Image quality, coverage of the pulmonary arteries, delineation of patent segmental and sub-segmental vessels and pathological findings were assessed. A total of 1980 vessels were evaluated. RESULTS: Sagittal 3D-MRA was superior in overall image quality and complete coverage of the vessels compared to coronal MRA, 18 % of subsegmental and 4.3 % of segmental arteries as well as 1.1 % of the lobar vessels were not covered by coronal acquisition. Only 0.5 % of sagittal subsegments were missed. The number of depicted patent segmental and subsegmental arteries was higher in sagittal MRA (460 vs 489 and 573 vs 649, respectively), the total difference of patent vessels was 105. Sagittal MRA revealed more pathological findings in segmental arteries (especially thrombotic material and stenoses). CONCLUSION: Sagittal CE-MRA of the pulmonary arteries with higher resolution and short acquisition time proved to be superior in all assessed criterias like image quality, vessel coverage, depiction of patent peripheral arteries and pathological findings compared to coronal MRA. The applied sagittal MRA is recommended for the routine practise in diagnostic evaluation of patients with CTEPH.


Assuntos
Hipertensão Pulmonar/diagnóstico , Angiografia por Ressonância Magnética , Artéria Pulmonar , Embolia Pulmonar/diagnóstico , Doença Crônica , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Embolia Pulmonar/cirurgia
19.
J Nematol ; 36(2): 147-52, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19262800

RESUMO

Total DNA was isolated from individual nematodes of the species Longidorus helveticus, L. macrosoma, L. arthensis, L. profundorum, L. elongatus, and L. raskii collected in Switzerland. The ITS region and D1-D2 expansion segments of the 26S rDNA were amplified and cloned. The sequences obtained were aligned in order to investigate sequence diversity and to infer the phylogenetic relationships among the six Longidorus species. D1-D2 sequences were more conserved than the ITS sequences that varied widely in primary structure and length, and no consensus was observed. Phylogenetic analyses using the neighbor-joining, maximum parsimony and maximum likelihood methods were performed with three different sequence data sets: ITS1-ITS2, 5.8S-D1-D2, and combining ITS1-ITS2+5.8S-D1-D2 sequences. All multiple alignments yielded similar basic trees supporting the existence of the six species established using morphological characters. These sequence data also provided evidence that the different regions of the rDNA are characterized by different evolution rates and by different factors associated with the generation of extreme size variation.

20.
Clin Biochem ; 36(7): 505-10, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14563442

RESUMO

OBJECTIVE: To evaluate 13C-NMR spectroscopy as a method for fat quantitation in human feces without time consuming or unpleasant preparation steps. DESIGN AND METHODS: Stool samples of seven healthy subjects were collected for 18 days before and during oral intake of the inhibitor of gastrointestinal lipases Orlistat. Fecal lipid content was determined first using 13C-NMR, then by conventional gravimetry after homogenization and Bligh & Dyer lipid extraction. RESULTS: The correlation between gravimetry and 13C-NMR was excellent (R2 = 0.91). In repeated measurements, the mean percentage error was 2.8%. On average, 13C-NMR yielded 1.27 g less fat than gravimetry. Orlistat efficacy for fat excretion assessed by 13C-NMR and by gravimetry was 34.3% and 33.9%, respectively. CONCLUSIONS: With a total measurement time of three minutes, 13C-NMR spectroscopy of unprocessed whole stool provides an accurate alternative to gravimetry for assessing total fecal fat excretion. 13C-NMR is superior with regard to practicability and speed.


Assuntos
Gorduras/análise , Fezes/química , Calibragem , Isótopos de Carbono , Humanos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...