Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 19(12): 2993-3001, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19588149

RESUMO

To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P<0.001, kappa=0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa=0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot.


Assuntos
Angiografia Digital , Diabetes Mellitus Tipo 2/patologia , Pé Diabético/patologia , Pé/irrigação sanguínea , Pé/patologia , Gadolínio , Compostos Organometálicos , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Magn Reson Med ; 62(2): 476-87, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19488992

RESUMO

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and H(2)(15)O positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the arterial input function (AIF), even at low doses of 0.025 mmol/kg body weight (BW). To correct for nonlinearity, a calibration curve was calculated on the basis of the signal equation. The required accuracy of equation parameters (like longitudinal relaxation time) was evaluated. Error analysis estimates <5% over-/underestimation of the corrected SI. Comparison of PET and MR flow values yielded a significant correlation (P < 0.001) in dorsal regions where signal-to-noise ratio (SNR) was sufficient. Changes in PBF due to the correction method were significant (P < 0.001) and resulted in a better agreement: mean values (standard deviation) in units of ml/min/100 ml lung tissue were 59 (15) for PET, 112 (28) for uncorrected MRI, and 80 (21) for corrected MRI.


Assuntos
Artefatos , Gadolínio DTPA , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos , Circulação Pulmonar/fisiologia , Animais , Meios de Contraste , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...