Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chem Commun (Camb) ; 56(27): 3899-3902, 2020 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-32140693

RESUMO

Although the chemistry of frustrated Lewis pairs (FLPs) has seen tremendous developments, investigations on anionic, mono-molecular FLPs are still scarce and 1,3-zwitterions are unknown. Herein, synthesis of a K/OR phosphinidenoid complex bearing a Si-Cl function is reported and, hence, can serve as a synthetic equivalent for a 1,3-zwitterion to allow access to rare and novel heterocyclic P-ligands.

2.
Chemistry ; 24(24): 6473-6478, 2018 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-29470864

RESUMO

A combined theoretical and experimental study on the formation and reactivity of a P-OTEMP (P-bound TEMPO (TEMPO=2,2,6,6-tetramethyl-piperidin-1-oxyl)) substituted 1,3,2-diazaphospholane W(CO)5 complex is presented, including DFT-based mechanistic details. The complex possesses a thermally labile O-N bond that cleaves homolytically yielding the transient 1,3,2-diazaphospholane-2-oxyl complex [(CO)5 W(R2 PO. )], which acts as a radical initiator for styrene polymerization under ambient conditions.

3.
Vet Rec Open ; 4(1): e000197, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28761667

RESUMO

The surgical evaluation of haemorrhagic infarcted intestine and the decision for or against bowel resection require a lot of experience and are subjective. The aim of this prospective, clinical study was to examine the correlation between oxygen saturation and small intestinal wall (IW) thickness, using two objective methods. In 22 colicky horses, the blood flow, oxygen saturation and relative amount of haemoglobin were measured intraoperatively via laser Doppler and white light spectroscopy (O2C, oxygen to see, LEA Medizintechnik) at six measuring points (MPs) in small and large intestines. Furthermore, the IW thickness was measured ultrasonographically. Nine of 22 horses had an increased small IW thickness greater than 4 mm (Freeman 2002, Scharner and others 2002, le Jeune and Whitcomb 2014) at measuring point 1 (MP1) (strangulated segment), four horses had a thickened bowel wall at measuring point 3 (MP3) (poststenotic) and one at measuring point 2 (MP2). The oxygen saturation was 0 at MP1 in six horses, at MP3 in two horses and at MP2 (prestenotic) in one. Oxygen saturation and small IW thickness were independent of each other at MP1 and MP2. At MP3, the two parameters were negatively correlated. In summary, it is not possible to draw conclusions about oxygen saturation based on IW thickness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...