Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 30(5): 535-42, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21173699

RESUMO

PURPOSE: To determine the association between mucin ball formation and corneal infiltrative events (CIEs) during continuous wear with lotrafilcon A silicone hydrogel contact lenses. METHODS: Subjects (n = 205) in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study wore lotrafilcon A contact lenses for 12 months of continuous wear. The primary outcome was a CIE. Kaplan-Meier methods were used to estimate the unadjusted cumulative incidence of remaining CIE free stratified by mucin ball presence. Cox proportional hazards regression was used to model the hazard of developing a CIE as a function of mucin ball formation and other covariates. RESULTS: Over half (54.2%) of the subjects displayed some presence of mucin balls during at least 1 visit and about one third (32.8%) displayed repeated episodes. Mucin ball scores were correlated between the 2 eyes and weakly correlated with corneal curvature (P ≤ 0.005). Univariate analyses revealed that the relative hazard for a CIE was 0.35 [95% confidence interval (CI), 0.19-0.68] if a single episode of mucin balls was detected and 0.17 (95% CI, 0.06-0.43) if repeated episodes were detected. Upon multivariate analysis, repeated presence of mucin balls was associated with an 84% decreased hazard of experiencing a CIE (hazard ratio: 0.16; 95% CI, 0.06-0.44). CONCLUSIONS: The presence of mucin balls is significantly associated with a decreased incidence of CIEs, and the effect is greatest when they are repeatedly present over time. We hypothesize that the mucin ball presence represents a more concentrated or viscous mucus layer, which prevents upregulation of the immune response against bacterial ligands.


Assuntos
Lentes de Contato de Uso Prolongado , Córnea/metabolismo , Proteínas do Olho/metabolismo , Mucinas/metabolismo , Adulto , Feminino , Fluorofotometria , Humanos , Hidrogéis , Masculino , Estudos Prospectivos , Silicones , Adulto Jovem
2.
Invest Ophthalmol Vis Sci ; 51(11): 5421-30, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20538985

RESUMO

PURPOSE: This study determined which microbiologic, clinical, demographic, and behavioral factors are associated with corneal infiltrative events (CIEs) during continuous wear of silicone hydrogel (SH) contact lenses. METHODS: Subjects (n = 205) were fitted with lotrafilcon A lenses for continuous wear and observed for 1 year. The main exposures of interest were corneal staining and bacterial lens contamination. Kaplan-Meier (KM) plots were used to estimate the cumulative unadjusted probability of remaining CIE free, and Cox proportional hazards regression was used to model the hazard of having a CIE, as a function of key predictor variables. RESULTS: The KM-unadjusted cumulative probability of remaining CIE free was 73.3%. Approximately 53% of subjects had repeated episodes of corneal staining (mild or greater), and 11.3% had repeated episodes of moderate or greater corneal staining. Corneal staining was not associated with the development of a CIE. The frequency of substantial bacterial bioburden on worn lenses at the time of a CIE was 64.7%, compared with only 12.2% during uncomplicated wear. The presence of substantial lens bacterial bioburden was associated with the development of a CIE (adjusted hazards ratio [HR], 8.66; 95% confidence interval [CI], 2.88-26.01). Smoking was also associated with a CIE (adjusted HR, 4.13; 95% CI, 1.27-13.45). CONCLUSIONS: Corneal staining is common during continuous wear of SH lenses, but it is not associated with the development of a CIE. Smoking and substantial lens bacterial bioburden pose prominent risks of a CIE. In this study, more than 70% of the total risk of CIE in those with substantial lens bioburden is attributable to this exposure. (ClinicalTrials.gov number, NCT00727402).


Assuntos
Bactérias/isolamento & purificação , Aderência Bacteriana/fisiologia , Lentes de Contato Hidrofílicas/microbiologia , Úlcera da Córnea/microbiologia , Hidrogéis , Silicones , Adolescente , Adulto , Bactérias/metabolismo , Úlcera da Córnea/diagnóstico , Feminino , Fluorofotometria , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Probabilidade , Estudos Prospectivos , Fatores de Risco , Células-Tronco , Adulto Jovem
3.
Ophthalmic Plast Reconstr Surg ; 24(3): 237-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18520848

RESUMO

A tree surgeon suffered a traumatic floor fracture complicated by multiple organic foreign bodies. CT confirmed a left floor fracture and medial wall fracture and decreased attenuation in the inferior orbit and maxillary sinus. Exploration of the orbital floor led to the removal of multiple wooden fragments up to 2.5 cm in length. Additional surgeries led to the removal of additional wooden fragments. Detection of organic intraorbital foreign bodies requires a high degree of clinical suspicion and close consultation with a radiologist.


Assuntos
Acidentes de Trabalho , Corpos Estranhos no Olho/diagnóstico , Ferimentos Oculares Penetrantes/diagnóstico , Órbita/lesões , Fraturas Orbitárias/diagnóstico por imagem , Madeira , Adulto , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/cirurgia , Humanos , Masculino , Fraturas Orbitárias/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...