1.
J Neural Eng ; 13(6): 066020, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27819256

RESUMO

OBJECTIVE: Acquisition of reliable and robust neural recordings with intracortical neural probes is a persistent challenge in the field of neuroprosthetics. We developed a multielectrode array technology to address chronic intracortical recording reliability and present in vivo recording results. APPROACH: The 2 × 2 Parylene sheath electrode array (PSEA) was microfabricated and constructed from only Parylene C and platinum. The probe includes a novel three-dimensional sheath structure, perforations, and bioactive coatings that improve tissue integration and manage immune response. Coatings were applied using a sequential dip-coating method that provided coverage over the entire probe surface and interior of the sheath structure. A sharp probe tip taper facilitated insertion with minimal trauma. Fabricated probes were subject to examination by optical and electron microscopy and electrochemical testing prior to implantation. MAIN RESULTS: 1 × 2 arrays were successfully fabricated on wafer and then packaged together to produce 2 × 2 arrays. Then, probes having electrode sites with adequate electrochemical properties were selected. A subset of arrays was treated with bioactive coatings to encourage neuronal growth and suppress inflammation and another subset of arrays was implanted in conjunction with a virally mediated expression of Caveolin-1. Arrays were attached to a custom-made insertion shuttle to facilitate precise insertion into the rat motor cortex. Stable electrophysiological recordings were obtained during the period of implantation up to 12 months. Immunohistochemical evaluation of cortical tissue around individual probes indicated a strong correlation between the electrophysiological performance of the probes and histologically observable proximity of neurons and dendritic sprouting. SIGNIFICANCE: The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording. This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.


Assuntos
Córtex Cerebral/fisiologia , Materiais Revestidos Biocompatíveis/química , Eletrocorticografia/instrumentação , Eletrodos Implantados , Próteses Neurais , Polímeros/química , Xilenos/química , Animais , Axônios , Caveolina 1/biossíntese , Caveolina 1/genética , Proliferação de Células , Córtex Cerebral/citologia , Dendritos , Técnicas Eletroquímicas , Imuno-Histoquímica , Platina , Desenho de Prótese , Ratos , Razão Sinal-Ruído
2.
J Biomed Mater Res B Appl Biomater ; 104(2): 357-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25809504

RESUMO

The biologically derived hydrogel Matrigel (MG) was used to coat a Parylene-based sheath intracortical electrode to act as a mechanical and biological buffer as well as a matrix for delivering bioactive molecules to modulate the cellular response and improve recording quality. MG was loaded with dexamethasone to reduce the immune response together with nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF) to maintain neuronal density and encourage neuronal ingrowth toward electrodes within the sheath. Coating the Parylene sheath electrode with the loaded MG significantly improved the signal-to-noise ratio for neural events recorded from the motor cortex in rat for more than 3 months. Electron microscopy showed even coverage of both the Parylene substrate and the platinum recording electrodes. Electrochemical impedance spectroscopy (EIS) of coated electrodes in 1× phosphate-buffered saline demonstrated low impedance required for recording neural signals. This result was confirmed by in vivo EIS data, showing significantly decreased impedance during the first week of recording. Dexamethasone, NGF, and BDNF loaded into MG were released within 1 day in 1× phosphate-buffered saline. Although previous studies showed that MG loaded with either the immunosuppressant or the neurotrophic factor cocktail provided modest improvement in recording quality in a 1-month in vivo study, the combination of these bioactive molecules did not improve the signal quality over coating probes with only MG in a 3-month in vivo study. The MG coating may further improve recording quality by optimizing the in vivo release profile for the bioactive molecules.


Assuntos
Materiais Revestidos Biocompatíveis/química , Colágeno/química , Eletrodos Implantados , Laminina/química , Córtex Motor/metabolismo , Neurônios Motores/metabolismo , Polímeros/química , Proteoglicanas/química , Xilenos/química , Animais , Fator Neurotrófico Derivado do Encéfalo/farmacologia , Células Cultivadas , Dexametasona/farmacologia , Combinação de Medicamentos , Masculino , Córtex Motor/citologia , Neurônios Motores/citologia , Fator de Crescimento Neural/farmacologia , Ratos , Ratos Sprague-Dawley
3.
Artigo em Inglês | MEDLINE | ID: mdl-25570971

RESUMO

We introduce a micro-biochemical administration module (µBAM) for generating chemical gradients for use in axonal guidance studies. The device is designed to be simple to use, require minimal packaging, and be operated using only a pipette. A passive pumping mechanism is utilized to pump liquid through a SU-8 microchannel and then the micropore on the Parylene cap of the microchannel. The achievable flow rate delivery through the micropore was characterized and manipulated by varying the drop volumes used to passively drive fluid flow into the device. Biochemicals controllably delivered using this module can be combined with neuronal cell cultures to form chemical gradients for axonal guidance studies.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Animais , Axônios/fisiologia , Células Cultivadas , Desenho de Equipamento , Humanos , Pressão Hidrostática , Neurônios/citologia , Porosidade
4.
Lab Chip ; 13(4): 554-61, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23160191

RESUMO

A Parylene C neural probe with a three dimensional sheath structure was designed, fabricated, and characterized. Multiple platinum (Pt) electrodes for recording neural signals were fabricated on both inner and outer surfaces of the sheath structure. Thermoforming of Parylene was used to create the three dimensional sheath structures from flat surface micromachined microchannels using solid microwires as molds. Benchtop electrochemical characterization was performed on the thin film Pt electrodes using cyclic voltammetry and electrochemical impedance spectroscopy and showed that electrodes possessed low impedances suitable for neuronal recordings. A procedure for implantation of the neural probe was developed and successfully demonstrated in vitro into an agarose brain tissue model. The electrode-lined sheath will be decorated with eluting neurotrophic factors to promote in vivo neural tissue ingrowth post-implantation. These features will enhance tissue integration and improve recording quality towards realizing reliable chronic neural interfaces.


Assuntos
Eletrodos Implantados , Neurônios/fisiologia , Polímeros/química , Xilenos/química , Estimulação Elétrica , Platina/química
5.
Artigo em Inglês | MEDLINE | ID: mdl-23367082

RESUMO

We present the preliminary electrochemical characterization of 3D Parylene C sheath microelectrode array probes towards realizing reliable chronic neuroprosthetic recordings. Electrochemical techniques were used to verify electrode integrity after our novel post-fabrication thermoforming process was applied to flat surface micromachined structures to achieve a hollow sheath probe shape. Characterization of subsequent neurotrophic coatings was performed and accelerated life testing was used to simulate six months in vivo. Prior to probe implantation, crosstalk was measured and electrode surface properties were evaluated through the use of electrochemical impedance spectroscopy.


Assuntos
Materiais Revestidos Biocompatíveis/química , Eletrodos Implantados , Microeletrodos , Polímeros/química , Xilenos/química , Impedância Elétrica , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Implantação de Prótese , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Microelectromech Syst ; 19(1): 215-228, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21318081

RESUMO

We present the first electrochemical actuator with Parylene bellows for large-deflection operation. The bellows diaphragm was fabricated using a polyethylene-glycol-based sacrificial molding technique followed by coating in Parylene C. Bellows were mechanically characterized and integrated with a pair of interdigitated electrodes to form an electrochemical actuator that is suitable for low-power pumping of fluids. Pump performance (gas generation rate and pump efficiency) was optimized through a careful examination of geometrical factors. Overall, a maximum pump efficiency of 90% was achieved in the case of electroplated electrodes, and a deflection of over 1.5 mm was demonstrated. Real-time wireless operation was achieved. The complete fabrication process and the materials used in this actuator are bio-compatible, which makes it suitable for biological and medical applications.