Talanta ; 106: 350-9, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23598137

RESUMO

In this research, a greener chromatography employing a short column, Zorbax SB C18 cartridge (12.5 × 4.6 mm, 5 µm) commonly used as a guard column in a reverse phase high performance liquid chromatography (RP-HPLC), was utilized as the analytical column in conjunction with a more eco-friendly micellar mobile phase of sodium dodecyl sulfate (SDS) for separation tertiary mixtures of local anesthetics and antihistamines; and binary mixture of colds drugs; and quaternary mixture of some parabens with different separation conditions. The chromatographic behavior of these analytes was studied to demonstrate separation efficiency of this guard column in a micellar mobile phase. Moreover, this column and SDS mobile phase was exploited for determination of parabens in 64 samples of cosmetic product, both those that were produced locally in the community and those that were commercially manufactured. Linear calibration graphs of the parabens as detected at 254 nm were obtained in the range of 1-100 µmol L(-1) with R(2)>0.9990. Percentage recoveries were 92.4-109.2 with %RSD<3, and the limit of detection and quantitation were 0.04-0.10 and 0.20-0.80 µmol L(-1), respectively. This analytical system is not only greener but also faster and employing simpler sample preparation than a conventional liquid chromatographic system.


Assuntos
Anestésicos Locais/análise , Cromatografia de Fase Reversa/métodos , Cosméticos/química , Química Verde , Antagonistas dos Receptores Histamínicos/análise , Parabenos/análise , Calibragem , Cromatografia de Fase Reversa/instrumentação , Misturas Complexas/química , Humanos , Limite de Detecção , Micelas , Dodecilsulfato de Sódio
2.
Talanta ; 61(6): 879-88, 2003 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-18969254

RESUMO

Optimized separation of a mixture of 16 priority pollutant polycyclic aromatic hydrocarbons (PAHs) by high performance liquid chromatography (HPLC) using the sequential simplex optimization method was accomplished by varying the starting and ending compositions of acetonitrile and water, linear gradient time, mobile phase flow rate, column temperature and holding time of the final mobile phase composition. Focusing on the two sets of difficult-to-separate pairs (acenaphthene-fluorene and benzo[g,h,i]perylene-indeno[1,2,3-c,d]pyrene), analysis time was reduced by about ten percent through the use of an organic modifier (isopropanol or methanol), under both optimum and near-optimum conditions, while maintaining good separation of the remaining PAHs. High sensitivity for all of the 16 PAHs was achieved by wavelength programming during elution using five wavelengths (224, 235, 254 270 and 296 nm), depending upon the molar absorptivities of the individual compounds. Detection limits (DLs) ranging from 0.002 (benzo[a]pyrene) to 0.140 mug ml(-1) (acenaphthene) were achieved for this set of 16 standard compounds.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...