Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont Res ; 64(4): 485-489, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32063544

RESUMO

PURPOSE: The present study aimed to examine three methods for imaging a complete denture form and to discuss the geometric assessment and availability of these methods. METHODS: Three methods were used: cone-beam computed tomography (CBCT), desktop dental scanning (DDS), and handheld optical scanning (HOS). Three sides of a cuboid resin block of a known size were measured on the captured images. Ten upper and lower complete dentures were digitized using each of the three methods. The denture forms in the standard triangulated language format were reconstructed using the computer aided design software with three resolutions: 0.1, 0.5 and 1.0. The two images were superimposed through a least-square algorithm, and the mean differences were examined among the three types of imaging methods and resolutions. RESULTS: The smallest mean differences and variations were obtained for CBCT and DDS, followed by HOS in the experiment using resin block. The lengths of longitudinal and horizontal sides were shortened in CBCT and DDS, whereas the height was shortened in HOS. The variations in each direction were very small by repetitive imaging within every imaging method. The difference between the CBCT and DDS was significantly smaller than that in the other two groups in experiment using actual dentures. The influence of resolution was comparatively low. CONCLUSIONS: The results suggested that CBCT and DDS had a similar geometric assessment, but that of the HOS was lower.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Prótese Total , Algoritmos , Desenho Assistido por Computador , Imageamento Tridimensional
2.
J Oral Sci ; 62(1): 40-42, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31996521

RESUMO

The purpose of this study was to evaluate the influence of various polishing protocols on the surface roughness of polyetheretherketone (PEEK) and identify an effective polishing method of dental prostheses at the chairside. The PEEK specimens were assigned to seven groups with different protocols: no additional polishing (NT); polishing using a rubber point (C); polishing using "silky shine" (S); polishing using "aqua blue paste" (A); protocol C followed by protocol S (CS); protocol C followed by protocol A (CA); and protocol C followed by protocols S and A (CSA). The surface roughness (Sa and Ra) of the polished surfaces was measured. The surface roughness decreased in the following order of groups: NT, C, S, CS, CSA, CA, and A. In Groups C and S, wide deep pits formed by abrasive grains of SiC paper were observed, whereas only fine linear structures were observed on the surface in other groups. With respect to the polishing protocol of PEEK, clinically acceptable surface roughness was obtained using a soft polishing brush and agent for more than 3 min.


Assuntos
Polimento Dentário , Cetonas , Benzofenonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Propriedades de Superfície
3.
Dent J (Basel) ; 7(3)2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31374927

RESUMO

These days, new prosthodontic materials are appearing with the development of digitalization. Among these, the use of polyetheretherketone (PEEK) as the clasp of removable partial dentures has been proposed. The adhesive strength between the PEEK and acrylic resin influences the probability of denture fracture. To investigate the effect of PEEK surface treatments on the shear bond strength to acrylic resin, five surface treatment conditions of PEEK were analyzed: 1. no treatment; 2. ceramic primer application; 3. Al2O3 sandblasting; 4. Rocatec; and 5. Rocatec with ceramic primer application, comparing with a metal primer-treated Co-Cr alloy. Two kinds of autopolymerizing resin (Unifast II and Palapress Vario) were used as bonding materials. The specimens were evaluated to determine the bond strength. Rocatec treatment with ceramic primer application yielded the highest bond strengths (12.71 MPa and 15.32 MPa, respectively, for Unifast II and Palapress Vario). When compared to a metal primer-treated Co-Cr alloy, the bond strength of PEEK to Unifast II was similar, whereas it was about 60% of that to Palapress Vario. Rocatec treatment, combined with ceramic primer, showed the highest bond strength of PEEK to acrylic resin. Treatment of PEEK will enable its use as the clasp of removable dentures and the fixation of PEEK prostheses.

4.
J Oral Sci ; 61(1): 140-145, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30918210

RESUMO

Denture plaque is a biofilm composed of various microorganisms aggregated with saliva. Various denture cleansers and cleaning apparatuses have been developed and studied. However, the optimum water temperature for denture cleaning is unknown. Therefore, the present study investigated the effects of water temperature during ultrasonic denture cleaning. In vitro, resin disks with artificial Candida albicans biofilm were pressed onto Candida GE media after ultrasonic cleaning with water at different temperatures for 5 min. The media were subsequently cultured at 37°C for 24 h. The colonies formed were observed and colony areas were quantified using ImageJ software (US National Institutes of Health, Bethesda, MD, USA). In situ, the bacterial count and degree of cleanliness on the tissue surface of maxillary dentures were measured before and after ultrasonic cleaning with water at different temperatures for 5 min. Changes in bacterial counts and cleanliness were calculated for each temperature. The ratio of the area occupied by bacterial colonies in vitro and reduction rates in situ after cleaning with warm water were markedly less than those observed after cleaning with cold water. Therefore, ultrasonic denture cleaning with warm water is more effective.


Assuntos
Dentaduras , Desinfecção/métodos , Temperatura Alta , Ondas Ultrassônicas , Água , Bactérias/isolamento & purificação , Biofilmes , Candida albicans/isolamento & purificação , Contagem de Colônia Microbiana , Meios de Cultura , Dentaduras/microbiologia
5.
Dent J (Basel) ; 7(1)2019 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-30609778

RESUMO

Clasp retainers made of metal alloys may be esthetically unappealing or cause allergic reactions. To investigate alternative materials, we used the nonfiller polyetheretherketone (PEEK) to fabricate the clasp retainer of a removable partial denture for the mandibular bilateral distal free-end abutment of an 84-year-old female. Two years later, few color and texture changes of PEEK were found macroscopically. The rest part and the clasp arm fitted well without any deformation. There were no particular occlusal or periodontal problems. Subjective satisfaction was expressed by both the practitioner and the patient.

6.
Dent J (Basel) ; 5(4)2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29563441

RESUMO

Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

7.
J Prosthodont Res ; 61(1): 81-86, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27345254

RESUMO

PURPOSE: To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. METHODS: The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. CONCLUSION: This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit.


Assuntos
Desenho Assistido por Computador , Planejamento de Dentadura/métodos , Prótese Total , Impressão Tridimensional , Força de Mordida , Desenho Assistido por Computador/instrumentação , Humanos , Impressão Tridimensional/instrumentação
8.
Int J Comput Dent ; 19(3): 193-202, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27644177

RESUMO

OBJECTIVES: We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. MATERIALS AND METHODS: Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. RESULTS: The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. CONCLUSION: The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.


Assuntos
Técnica de Moldagem Odontológica , Planejamento de Dentadura , Prótese Total , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Fotogrametria/métodos , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/patologia , Desenho Assistido por Computador , Estudos de Viabilidade , Feminino , Humanos , Arcada Edêntula/patologia , Masculino , Maxila/patologia , Modelos Dentários
9.
J Prosthodont Res ; 60(3): 206-12, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26822762

RESUMO

PURPOSE: The aim of this study was to compare 3-dimensional surfaces of study and working casts for edentulous jaws and to evaluate the accuracy of preliminary impressions with a view to the future application of digital dentistry for edentulous jaws. METHODS: Forty edentulous volunteers were serially recruited. Nine dentists took preliminary and final impressions in a routine clinical work-up. The study and working casts were digitized using a dental 3-dimensional scanner. The two surface images were superimposed through a least-square algorithm using imaging software and compared qualitatively. Furthermore, the surface of each jaw was divided into 6 sections, and the difference between the 2 images was quantitatively evaluated. RESULTS: Overall inspection showed that the difference around residual ridges was small and that around borders were large. The mean differences in the upper and lower jaws were 0.26mm and 0.45mm, respectively. The maximum values of the differences showed that the upward change mainly occurred in the anterior residual ridge, and the downward change mainly in the posterior border seal, and the labial and buccal vestibules, whereas every border of final impression was shortened in the lower jaw. The accuracy in all areas except the border, which forms the foundation, was estimated to be less than 0.25mm. CONCLUSION: Using digital technology, we here showed the overall and sectional accuracy of the preliminary impression for edentulous jaws. In our clinic, preliminary impressions have been made using an alginate material while ensuring that the requisite impression area was covered.


Assuntos
Revestimento para Fundição Odontológica , Técnica de Moldagem Odontológica , Imageamento Tridimensional , Arcada Edêntula , Idoso , Idoso de 80 Anos ou mais , Humanos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...