Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Pol J Radiol ; 87: e246-e256, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774216

RESUMO

Purpose: To examine the optimal number and combination of b-values in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the major salivary glands. Material and methods: IVIM-DWI was performed on 10 healthy volunteers using 13 b-values (low b-values: 0-100 s/mm2; high b-values: 200-1000 s/mm2). The IVIM parameters and apparent diffusion coefficient of the bilateral major salivary glands were calculated using 13 b-values and were considered the standard values. We sequentially reduced the number of b-values to 10, 8, 6, and 5. The parameters in each combination were calculated. The standard values were compared with the parameters from each reduced b-value in IVIM-DWI. The Wilcoxon signed-rank test was used to determine whether there were any differences between the parameters in each combination. Bonferroni correction was conducted for multiple comparisons. Results: There were no significant differences between the standard values and parameters from the 2 combinations of 6 b-values. However, significant differences were observed between the standard values and parameters from some combinations of only 2 low or only 2 high b-values. Conclusions: IVIM-DWI of the major salivary glands could be performed using a minimum of 6 b-values. However, they should contain 3 low and 3 high b-values.

2.
Br J Radiol ; 89(1067): 20160007, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27635791

RESUMO

OBJECTIVE: To investigate the efficacy of the radial acquisition regime (RADAR) for acquiring head and neck MR images. METHODS: 15 healthy volunteers underwent imaging with 4 sequences [fast spin echo T2 weighted imaging (FSE-T2WI), RADAR T2 weighted imaging (RADAR-T2WI), single-shot echo planar imaging diffusion-weighted imaging (SS-EPI-DWI) and RADAR diffusion-weighted imaging (RADAR-DWI)]. Both standard images and images during periodic mouth motion were acquired. Two radiologists scored the overall image artefacts and detectability of several anatomical structures without knowledge of sequence type. For each sequence, image distortion was quantitatively compared by the anteroposterior to right-left ratio of several anatomical structures. The mean scores of artefacts and distortion of several anatomical structures were compared using the multiple comparison test. The detectabilities were compared using the Wilcoxon signed-rank test. RESULTS: Regardless of mouth motion, RADAR-T2WI was significantly superior to FSE-T2WI in artefacts and oral-area detectability (p < 0.01), and RADAR-DWI was significantly superior to SS-EPI-DWI in terms of artefacts (p < 0.01). In terms of image distortion, RADAR-DWI was significantly superior to SS-EPI-DWI (p < 0.01). CONCLUSION: RADAR-T2WI could replace FSE-T2WI as a conventional T2WI protocol for the head and neck. For the RADAR-DWI sequence, validation studies are needed. Advances in knowledge: RADAR-T2WI was superior to FSE-T2WI with regard to artefacts and detectability, and RADAR-DWI was superior in terms of artefacts compared with SS-EPI-DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Artefatos , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Masculino , Movimento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...