Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J S Afr Vet Assoc ; 89(0): e1-e3, 2018 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-30198297

RESUMO

Tonometry is one of the basic diagnostic tests used for the diagnosis of glaucoma and uveitis in veterinary ophthalmology. The Icare® Rebound Tonometer which is a new tonometric device has been shown to be useful in a wide range of species. Eyes (n = 48) of 24 Simmental and Montafon calves with a mean age of 7.5 weeks (2-16 weeks), male and female, were subjected to intraocular pressure (IOP) measurement using the Icare® Rebound Tonometer with calves standing and in lateral recumbency. The mean IOP was measured as 9.02 ± 2.38 mmHg in the right eye and 9.08 ± 2.55 mmHg in the left eye. No age-related change was found in intraocular pressure of the calves between 2 and 16 weeks of age. No difference in IOP values was observed between Simmental and Montafon calves. Body position had no effect on IOP in calves. The Icare® Rebound Tonometer was shown to be a suitable diagnostic device for IOP measurement in calves.


Assuntos
Pressão Intraocular/fisiologia , Postura/fisiologia , Tonometria Ocular/veterinária , África , Animais , Bovinos , Doenças dos Bovinos/diagnóstico , Feminino , Glaucoma/diagnóstico , Glaucoma/veterinária , Modelos Lineares , Masculino , Decúbito Dorsal/fisiologia , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...