Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Adv ; 10(26): eadl5270, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941456

RESUMO

Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth-inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.


Assuntos
Boidae , Manguito Rotador , Animais , Manguito Rotador/cirurgia , Boidae/fisiologia , Lesões do Manguito Rotador/cirurgia , Dente , Técnicas de Sutura/instrumentação , Fenômenos Biomecânicos , Humanos , Impressão Tridimensional
2.
J Orthop Res ; 40(9): 1981-1992, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34812543

RESUMO

Neonatal brachial plexus palsy (NBPP) occurs in approximately 1.5 of every 1,000 live births. The majority of children with NBPP recover function of the shoulder. However, the long-term risk of osteoarthritis (OA) in this population is unknown. The purpose of this study was to investigate the development of OA in a mouse model of transient neonatal shoulder paralysis. Neonatal mice were injected twice per week for 4 weeks with saline in the right supraspinatus muscle (Saline, control) and botulinum toxin A (BtxA, transient paralysis) in the left supraspinatus muscle, and then allowed to recover for 20 or 36 weeks. Control mice received no injections, and all mice were sacrificed at 24 or 40 weeks. BtxA mice exhibited abnormalities in gait compared to controls through 10 weeks of age, but these differences did not persist into adulthood. BtxA shoulders had decreased bone volume (-9%) and abnormal trabecular microstructure compared to controls. Histomorphometry analysis demonstrated that BtxA shoulders had higher murine shoulder arthritis scale scores (+30%), and therefore more shoulder OA compared to controls. Articular cartilage of BtxA shoulders demonstrated stiffening of the tissue. Compared with controls, articular cartilage from BtxA shoulders had 2-fold and 10-fold decreases in Dkk1 and BMP2 expression, respectively, and 3-fold and 14-fold increases in Col10A1 and BGLAP expression, respectively, consistent with established models of OA. In summary, a brief period of paralysis of the neonatal mouse shoulder was sufficient to generate early signs of OA in adult cartilage and bone.


Assuntos
Osteoartrite , Paralisia , Animais , Animais Recém-Nascidos , Toxinas Botulínicas Tipo A , Modelos Animais de Doenças , Camundongos , Osteoartrite/induzido quimicamente , Paralisia/induzido quimicamente , Manguito Rotador , Ombro
3.
Int J Solids Struct ; 2502022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38161357

RESUMO

Tears to the rotator cuff often require surgical repair. These repairs often culminate in re-tearing when sutures break through the tendon in the weeks following repair. Although numerous studies have been performed to identify suturing strategies that reduce this risk by balancing forces across sutures, none have accounted for how the viscoelastic nature of tendon influences load sharing. With the aim of providing insight into this problem, we studied how tendon viscoelasticity, tendon stiffness, and suture anchor spacing affect this balancing of forces across sutures. Results from a model of a three-row sutured re-attachment demonstrated that optimized distributions of suture stiffnesses and of the spacing of suture anchors can balance the forces across sutures to within a few percent, even when accounting for tendon viscoelasticity. Non-optimized distributions resulted in concentrated force, typically in the outermost sutures. Results underscore the importance of accounting for viscoelastic effects in the design of tendon to bone repairs.

4.
Sci Adv ; 7(48): eabi5584, 2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34826240

RESUMO

Architectured materials offer tailored mechanical properties but are limited in engineering applications due to challenges in maintaining toughness across their attachments. The enthesis connects tendon and bone, two vastly different architectured materials, and exhibits toughness across a wide range of loadings. Understanding the mechanisms by which this is achieved could inform the development of engineered attachments. Integrating experiments, simulations, and previously unexplored imaging that enabled simultaneous observation of mineralized and unmineralized tissues, we identified putative mechanisms of enthesis toughening in a mouse model and then manipulated these mechanisms via in vivo control of mineralization and architecture. Imaging uncovered a fibrous architecture within the enthesis that controls trade-offs between strength and toughness. In vivo models of pathology revealed architectural adaptations that optimize these trade-offs through cross-scale mechanisms including nanoscale protein denaturation, milliscale load-sharing, and macroscale energy absorption. Results suggest strategies for optimizing architecture for tough bimaterial attachments in medicine and engineering.

5.
J Vis Exp ; (152)2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31680671

RESUMO

Tendon disorders are common, affect people of all ages, and are often debilitating. Standard treatments, such as anti-inflammatory drugs, rehabilitation, and surgical repair, often fail. In order to define tendon function and demonstrate efficacy of new treatments, the mechanical properties of tendons from animal models must be accurately determined. Murine animal models are now widely used to study tendon disorders and evaluate novel treatments for tendinopathies; however, determining the mechanical properties of mouse tendons has been challenging. In this study, a new system was developed for tendon mechanical testing that includes 3D-printed fixtures that exactly match the anatomies of the humerus and calcaneus to mechanically test supraspinatus tendons and Achilles tendons, respectively. These fixtures were developed using 3D reconstructions of native bone anatomy, solid modeling, and additive manufacturing. The new approach eliminated artifactual gripping failures (e.g., failure at the growth plate failure rather than in the tendon), decreased overall testing time, and increased reproducibility. Furthermore, this new method is readily adaptable for testing other murine tendons and tendons from other animals.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiologia , Fenômenos Biomecânicos/fisiologia , Imageamento Tridimensional/métodos , Impressão Tridimensional , Animais , Feminino , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Modelos Animais , Reprodutibilidade dos Testes
6.
Sci Transl Med ; 11(481)2019 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-30814338

RESUMO

Tendon disorders represent the most common musculoskeletal complaint for which patients seek medical attention; inflammation drives tendon degeneration before tearing and impairs healing after repair. Clinical evidence has implicated the nuclear factor kappa-light-chain-enhancer of activated B cells (NF-κB) pathway as a correlate of pain-free return to function after surgical repair. However, it is currently unknown whether this response is a reaction to or a driver of pathology. Therefore, we aimed to understand the clinically relevant involvement of the NF-κB pathway in tendinopathy, to determine its potential causative roles in tendon degeneration, and to test its potential as a therapeutic candidate. Transcriptional profiling of early rotator cuff tendinopathy identified increases in NF-κB signaling, including increased expression of the regulatory serine kinase subunit IKKß, which plays an essential role in inflammation. Using cre-mediated overexpression of IKKß in tendon fibroblasts, we observed degeneration of mouse rotator cuff tendons and the adjacent humeral head. These changes were associated with increases in proinflammatory cytokines and innate immune cells within the joint. Conversely, genetic deletion of IKKß in tendon fibroblasts partially protected mice from chronic overuse-induced tendinopathy. Furthermore, conditional knockout of IKKß improved outcomes after surgical repair, whereas overexpression impaired tendon healing. Accordingly, targeting of the IKKß/NF-κB pathway in tendon stromal cells may offer previously unidentified therapeutic approaches in the management of human tendon disorders.


Assuntos
NF-kappa B/metabolismo , Transdução de Sinais , Tendões/metabolismo , Tendões/patologia , Doença Aguda , Adulto , Animais , Doença Crônica , Citocinas/metabolismo , Feminino , Fibroblastos/patologia , Humanos , Quinase I-kappa B/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Bibliotecas de Moléculas Pequenas/farmacologia , Células Estromais/metabolismo , Cicatrização , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...