1.
Perfusion ; 39(1): 5-6, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37977208
2.
Perfusion ; 38(8): 1543-1544, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37769665
3.
Perfusion ; 38(1): 5, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36534482
4.
Perfusion ; 37(1): 3-4, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34949137
5.
Perfusion ; 36(1): 4-5, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33357093
7.
Cardiovasc Eng Technol ; 10(3): 520-530, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31187397

RESUMO

PURPOSE: This study compares preload sensitivity of continuous flow (CF) VAD support to counterpulsation using the Windmill toroidal VAD (TORVAD). The TORVAD is a two-piston rotary pump that ejects 30 mL in early diastole, which increases cardiac output while preserving aortic valve flow. METHODS: Preload sensitivity was compared for CF vs. TORVAD counterpulse support using two lumped parameter models of the cardiovascular system: (1) an open-loop model of the systemic circulation was used to obtain ventricular function curves by isolating the systemic circulation and prescribing preload and afterload boundary conditions, and (2) a closed-loop model was used to test the physiological response to changes in pulmonary vascular resistance, systemic vascular resistance, heart rate, inotropic state, and blood volume. In the open-loop model, ventricular function curves (cardiac output vs left ventricular preload) are used to assess preload sensitivity. In the closed-loop model, left ventricular end systolic volume is used to assess the risk of left ventricular suction. RESULTS: At low preloads of 5 mmHg, CF support overpumps the circulation compared to TORVAD counterpulse support (cardiac output of 3.3 L/min for the healthy heart, 4.7 with CF support, and 3.5 with TORVAD counterpulse support) and has much less sensitivity than counterpulse support (0.342 L/min/mmHg for the healthy heart, 0.092 with CF support, and 0.306 with TORVAD counterpulse support). In the closed-loop model, when PVR is increased beyond 0.035 mmHg s/mL, CF support overpumps the circulation and causes ventricular suction events, but TORVAD counterpulse support maintains sufficient ventricular volume and does not cause suction. CONCLUSIONS: Counterpulse support with the TORVAD preserves aortic valve flow and provides physiological sensitivity across all preload conditions. This should prevent overpumping and minimize the risk of suction.


Assuntos
Contrapulsação/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Função Ventricular Esquerda , Valva Aórtica/fisiopatologia , Débito Cardíaco , Contrapulsação/efeitos adversos , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Teste de Materiais , Desenho de Prótese , Resistência Vascular
9.
Ann Thorac Surg ; 107(6): 1761-1767, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30586577

RESUMO

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) cause blood trauma that includes von Willebrand factor degradation, platelet activation, and subclinical hemolysis. Blood trauma contributes to bleeding, thrombosis, and stroke, which cause significant morbidity and mortality. The TORVAD (Windmill Cardiovascular Systems, Inc, Austin, TX) is a first-of-its kind, toroidal-flow LVAD designed to minimize blood trauma. We tested the hypothesis that the TORVAD causes less blood trauma than the HeartMate II (Abbott Laboratories, Pleasanton, CA) LVAD. METHODS: Whole human blood was circulated for 6 hours in ex vivo circulatory loops with a HeartMate II (n = 8; 10,000 rpm, 70 ± 6 mm Hg, 4.0 ± 0.1 L/min) or TORVAD (n = 6; 144 rpm, 72 ± 0.0 mm Hg, 4.3 ± 0.0 L/min). von Willebrand factor degradation was quantified with electrophoresis and immunoblotting. Platelet activation was quantified by cluster of differentiation (CD) 41/61 enzyme-linked immunosorbent assay (ELISA). Hemolysis was quantified by plasma free hemoglobin ELISA. RESULTS: The TORVAD caused significantly less degradation of high-molecular-weight von Willebrand factor multimers (-10% ± 1% vs -21% ± 1%, p < 0.0001), accumulation of low-molecular-weight von Willebrand factor multimers (22% ± 2% vs 45% ± 2%, p < 0.0001), and accumulation of von Willebrand factor degradation fragments (7% ± 1% vs 25% ± 6%, p < 0.05) than the HeartMate II. The TORVAD did not activate platelets, whereas the HeartMate II caused significant platelet activation (CD 41/61: 645 ± 20 ng/mL vs 1,581 ± 150 ng/mL, p < 0.001; normal human CD 41/61, 593 ng/mL; range, 400 to 800 ng/mL). Similarly, the TORVAD caused minimal hemolysis, whereas the HeartMate II caused significant hemolysis (plasma free hemoglobin: 11 ± 2 vs 109 ± 10 mg/dL, p < 0.0001; normal human plasma free hemoglobin <4 mg/dL). CONCLUSIONS: The TORVAD design, with markedly lower shear stress and pulsatile flow, caused significantly less blood trauma than the HeartMate II. LVADs with reduced blood trauma are likely to improve clinical outcomes and expand LVAD therapy into patients with less advanced heart failure.


Assuntos
Coração Auxiliar/efeitos adversos , Hemólise , Ativação Plaquetária , Fator de von Willebrand/metabolismo , Humanos , Desenho de Prótese
11.
Perfusion ; 32(7): 521-522, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28985706

Assuntos
Sistema Solar
12.
ASAIO J ; 63(2): 198-206, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27832001

RESUMO

This article provides an overview of the design challenges associated with scaling the low-shear pulsatile TORVAD ventricular assist device (VAD) for treating pediatric heart failure. A cardiovascular system model was used to determine that a 15 ml stroke volume device with a maximum flow rate of 4 L/min can provide full support to pediatric patients with body surface areas between 0.6 and 1.5 m. Low-shear stress in the blood is preserved as the device is scaled down and remains at least two orders of magnitude less than continuous flow VADs. A new magnetic linkage coupling the rotor and piston has been optimized using a finite element model (FEM) resulting in increased heat transfer to the blood while reducing the overall size of TORVAD. Motor FEM has also been used to reduce motor size and improve motor efficiency and heat transfer. FEM analysis predicts no more than 1°C temperature rise on any blood or tissue contacting surface of the device. The iterative computational approach established provides a methodology for developing a TORVAD platform technology with various device sizes for supporting the circulation of infants to adults.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Equipamento , Análise de Elementos Finitos , Humanos , Lactente , Modelos Cardiovasculares , Fluxo Pulsátil
14.
Perfusion ; 31(1): 5, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26646259
17.
18.
19.
ASAIO J ; 61(3): 259-65, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25485562

RESUMO

This article describes the stroke volume selection and operational design for the toroidal ventricular assist device (TORVAD), a synchronous, positive-displacement ventricular assist device (VAD). A lumped parameter model was used to simulate hemodynamics with the TORVAD compared with those under continuous-flow VAD support. Results from the simulation demonstrated that a TORVAD with a 30 ml stroke volume ejecting with an early diastolic counterpulse provides comparable systemic support to the HeartMate II (HMII) (cardiac output 5.7 L/min up from 3.1 L/min in simulated heart failure). By taking the advantage of synchronous pulsatility, the TORVAD delivers full hemodynamic support with nearly half the VAD flow rate (2.7 L/min compared with 5.3 L/min for the HMII) by allowing the left ventricle to eject during systole and thus preserving native aortic valve flow (3.0 L/min compared with 0.4 L/min for the HMII, down from 3.1 L/min at baseline). The TORVAD also preserves pulse pressure (26.7 mm Hg compared with 12.8 mm Hg for the HMII, down from 29.1 mm Hg at baseline). Preservation of aortic valve flow with synchronous pulsatile support could reduce the high incidence of aortic insufficiency and valve cusp fusion reported in patients supported with continuous-flow VADs.


Assuntos
Simulação por Computador , Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Humanos
20.
SELEÇÃO DE REFERÊNCIAS