Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int Emerg Nurs ; 62: 101144, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35279524

RESUMO

BACKGROUND: Critical care transport is an essential component of care system. Inadequacies in equipment, during the interhospital transport can lead to adverse event. OBJECTIVES: To verify the influence of physical transport conditions in the infusion pumps (IPs) performance and alarm activation. METHODS: Simulation-based study about IPs use during interhospital ground transportation. There were 54 simulations (18 flowmetric, 18 volumetric, 18 syringe IPs). The equipment were tested at 01, 05 and 50mL/h infusion flow. Descriptive and inferential statistical analysis, with a 5% significance level was performed. RESULTS: The effectively infused volume was lower than the expected volume for the 3 IPs types. Vibration was the variable with highest correlation in volume difference. Flowmetric IPs showed higher alarm frequency (50.0%), followed by syringe IPs (27.8%). Free flow predominated in flowmetric IP and airline and occlusion alarms in volumetric and syringe IP. Error percentage of delivered fluid ranged from 2.8% to 25.9% being more evident in flowmeter IPs. CONCLUSION: The infusion pumps showed infusion misfunctioning when subjected to physical transport conditions. Syringe IPs were more accurate for low flow administration, while for the administration of solutions at higher flow rate, the volumetric IP showed the highest accuracy.


Assuntos
Bombas de Infusão , Seringas , Humanos , Bombas de Infusão/efeitos adversos
2.
J Pediatr Nurs ; 61: e29-e34, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33863611

RESUMO

PURPOSE: To identify the incidence of delirium in a Pediatric Intensive Care Unit (PICU); to determine the factors associated with the occurrence of delirium and the agreement between two scales used for detection of pediatric delirium in critically ill children. DESIGNS AND METHOD: Descriptive longitudinal study carried out in a PICU. The sample consisted of 65 critically ill children admitted to the PICU, with more than 24 h of hospitalization, excluding children with neurological or cognitive impairment, hearing and visual impairment, chronic encephalopathy and declining consent to participate in the study. Two scales were applied, the Cornell Assessment of Pediatric Delirium (CAPD) and the Sophia Observation Withdrawal Symptoms - Pediatric Delirium Scale (SOS_PD). Descriptive and inferential statistical analysis, with a 5% significance level was performed. RESULTS: Delirium was identified in 7.7% of children, with duration of the disorder of about 2 days. A very good agreement (Kappa = 1; p-value <0.001) between the two scales was identified. CAPD presented positive predictive value of 80.0%. There was a statistical association between the occurrence of delirium and age less than 2 years (p = 0.060); female gender (p = 0.057); use of mechanical pulmonary ventilation (p = 0.034); antiemetics (p = 0.002); anticholinergics (p = 0.044), and changes in serum sodium and potassium (p = 0.053). CONCLUSION: Demographic, clinical, and pharmacological conditions were associated with the occurrence of delirium. PRACTICE IMPLICATIONS: Routine monitoring is the first step to any delirium prevention strategies, so delirium screening by the bedside nurse must be valued through a commitment to education and training.


Assuntos
Delírio , Brasil/epidemiologia , Criança , Pré-Escolar , Estado Terminal/epidemiologia , Delírio/diagnóstico , Delírio/epidemiologia , Feminino , Humanos , Incidência , Unidades de Terapia Intensiva , Unidades de Terapia Intensiva Pediátrica , Estudos Longitudinais
3.
Aust Crit Care ; 32(1): 21-27, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29580966

RESUMO

BACKGROUND: Hand hygiene is considered the single most effective means of reducing healthcare-associated infections, but improving and sustaining hand hygiene compliance remains a great challenge. OBJECTIVES: To compare hand hygiene compliance before and after interventions to promote adherence in a paediatric intensive care unit (PICU) and to identify predictors of intention to perform the behaviour "hand hygiene during patient care in the PICU". METHODS: A before and after study was conducted in three phases. Based on the World Health Organization guideline for hand hygiene compliance monitoring, 1261 hand hygiene opportunities were directly observed during routine patient care by two observers simultaneously, in a nine-bed PICU in Brazil, before and after infrastructure and educational interventions. To identify predictors of healthcare professionals' intention to perform the behaviour hand hygiene during patient care, a data collection instrument was designed based on the Theory of Planned Behaviour. Statistical analyses were undertaken using Chi-square test or the Fisher's exact test and regression analysis. A significance level of 5% (p < 0.05) was applied to all analyses. RESULTS: The hand hygiene compliance rate increased significantly from 27.3% in the "pre-intervention phase" to 33.1% in "phase 1-post-intervention," to 37.0% in "phase 2-post-intervention" (p = .010). Perceived social pressure (p = .026) was a determinant factor of intention to perform the behaviour. CONCLUSIONS: Hand hygiene compliance raised significantly after infrastructure, educational, and performance feedback interventions. However, despite the significant effect of the implemented interventions, the overall hand hygiene compliance rate was low. Perceived social pressure characterised a determinant factor of intention to perform the behaviour "hand hygiene during patient care in the PICU", reinforcing the need for behaviour determinants analysis when designing promotional interventions.


Assuntos
Infecção Hospitalar/prevenção & controle , Fidelidade a Diretrizes , Higiene das Mãos , Pessoal de Saúde , Controle de Infecções/métodos , Unidades de Terapia Intensiva Pediátrica , Adulto , Brasil , Cuidados Críticos , Humanos
4.
Nurs Crit Care ; 22(5): 276-283, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25779636

RESUMO

BACKGROUND: Maintaining endotracheal tube patency is critical for neonates receiving mechanical ventilation. Endotracheal tube suctioning removes accumulated secretions preventing potential adverse events, however is also potentially hazardous to the patient. OBJECTIVE: To compare respiratory rate, arterial blood oxygen saturation, heart rate and pain in newborns undergoing endotracheal tube suctioning with closed (CS) and open (OS) systems. METHODS: Randomized crossover trial with 13 newborns from two Brazilian hospitals. The respiratory rate, arterial blood oxygen saturation, heart rate and pain (Premature Infant Pain Profile) were analysed: immediately before (T1), during (T2), immediately after (T3), 10 min after (T4) and 30 min (T5) after endotracheal suctioning. RESULTS: The majority (11/85·0%) of the newborns were premature and 45% weighed less than 1000 g. No statistically significant difference was identified according to the use of CS or OS to all the parameters investigated. The main results demonstrated that in T2 arterial blood oxygen saturation was higher with CS (CS 93·0%; OS 89 · 0%; p = 0·561). In T3 there was an increase in respiratory rate average only with the use of OS (T1 50·0; T3 56·0). The pain score in T2 and heart rate in T3 were higher with OS without significant differences (p = 0·114; p = 0·479, respectively). CONCLUSION: There was no significant difference in the studied clinical parameters or presence and intensity of pain according to the two investigated techniques of endotracheal tube suctioning. RELEVANCE TO CLINICAL PRACTICE: This research can provide support for clinical practice regarding endotracheal tube suctioning of newborns describing that the use of closed systems was similar to the open system regarding pain presence and intensity, as well as, in the clinical effects analysed, in accordance with other studies produced in this field.


Assuntos
Intubação Intratraqueal/métodos , Oxigênio/sangue , Medição da Dor , Respiração Artificial/métodos , Sucção/métodos , Gasometria , Brasil , Estudos Cross-Over , Feminino , Frequência Cardíaca/fisiologia , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal/efeitos adversos , Masculino , Oximetria/métodos , Consumo de Oxigênio/fisiologia , Respiração Artificial/efeitos adversos , Resultado do Tratamento
5.
Am J Crit Care ; 18(4): 319-28; quiz 329, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19556410

RESUMO

BACKGROUND: Recent progress in identification of oral microorganisms has shown that the oropharynx can be a site of origin for dissemination of pathogenic organisms to distant body sites, such as the lungs. OBJECTIVE: To compare the oropharyngeal microbiological profile, duration of mechanical ventilation, and length of stay in the intensive care unit of children receiving mechanical ventilation who had pharmacological or nonpharmacological oral care. METHODS: A randomized and controlled study was performed in a pediatric intensive unit in São Paulo, Brazil. A total of 56 children were randomly assigned to an experimental group (n=27, 48%) that received oral care with use of 0.12% chlorhexidine digluconate or a control group (n=29, 52%) that received oral care without an antiseptic. Oropharyngeal secretions were collected and cultured on days 0, 2, and 4, and at discharge. RESULTS: The 2 groups had similar demographic characteristics, preexisting underlying diseases, and pharmacological, nutritional, and ventilatory support. Gram-negative bacteria were the predominant pathogens: Acinetobacter baumannii, Pseudomonas aeruginosa, Klebsiella pneumoniae, and Enter-obacter species. The 2 groups did not differ significantly in the colonization of normal (P= .72) or pathogenic (P= .62) flora, in the duration of mechanical ventilation (P= .67), or in length of stay in the intensive care (P= .22). CONCLUSION: Use of chlorhexidine combined with nonpharmacological oral care did not decrease the colonization profile, duration of mechanical ventilation, or length of stay in critically ill children receiving mechanical ventilation.


Assuntos
Anti-Infecciosos Locais/administração & dosagem , Clorexidina/análogos & derivados , Higiene Bucal/métodos , Orofaringe/microbiologia , Respiração Artificial/efeitos adversos , Administração Oral , Criança , Pré-Escolar , Clorexidina/administração & dosagem , Feminino , Bactérias Gram-Negativas/crescimento & desenvolvimento , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Infecções por Bactérias Gram-Negativas/etiologia , Infecções por Bactérias Gram-Negativas/microbiologia , Infecções por Bactérias Gram-Negativas/prevenção & controle , Humanos , Lactente , Masculino , Boca/efeitos dos fármacos , Boca/microbiologia , Orofaringe/efeitos dos fármacos , Estudos Prospectivos
6.
Heart Lung ; 35(6): 391-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17137940

RESUMO

BACKGROUND: Backrest elevation, defined as the angle of the backrest height above the horizontal position, is a common nursing intervention that is often used by subjective visual estimation in critically ill patients. OBJECTIVES: The aim of the study was to describe the magnitude of error during the subjective assessment of backrest elevation. METHODS: This prospective study was conducted in a sample of 160 subjects: 97 registered nurses, 48 undergraduate nursing students, and 15 nursing assistants. Data were collected by recording the degrees of backrest elevation identified by the subjects through an individual random presentation of the selected study angles of 20 degrees, 30 degrees, 35 degrees, 40 degrees, and 45 degrees. A measurement instrument was developed for determination of the angles. RESULTS: Of the 800 investigated angles, 14.9% were estimated accurately, 61.6% were overestimated, and 23.5% were underestimated, with an error average of 8 degrees (+/-13.5 degrees). It was determined that the larger the angle estimated, the greater the average error. A statically significant difference (P

Assuntos
Leitos , Cuidados Críticos/métodos , Estado Terminal/enfermagem , Postura , Adaptação Fisiológica/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
J. pediatr. (Rio J.) ; 82(5): 389-394, Sept.-Oct. 2006. tab
Artigo em Português, Inglês | LILACS | ID: lil-438358

RESUMO

OBJETIVO: Verificar variabilidade na determinação da linha axilar média como ponto externo de referência (PER), por diferentes profissionais de saú de, para a aferição de pressão venosa central em crianças. MÉTODOS: Estudo descritivo e de correlação realizado em uma unidade de cuidados intensivos pediátricos de um hospital universitário. Durante a determinação da linha axilar média como PER para a aferição da pressão venosa central, cinco avaliações realizadas no mesmo paciente por profissionais de saúde e uma realizada por um avaliador treinado foram comparadas. O resultado foi um total de 120 indicações de 44 profissionais de saúde, 17 (38,6 por cento) auxiliares e técnicos de enfermagem, 16 (36,3 por cento) enfermeiros e 11 (25,1 por cento) médicos, além de 24 identificações realizadas por avaliador treinado. Os dados foram analisados utilizando os testes do qui-quadrado, ANOVA, Kruskall-Wallis e teste t, fixando o nível de significância em 5 por cento. RESULTADOS: Houve diferença significante entre as identificações realizadas pelos profissionais de saúde e pelo avaliador (p < 0,001). Comparando a variabilidade das medidas realizadas pelos profissionais, 56 (46,7 por cento) foram menores do que a identificação do avaliador (variação de -0,5 até -9), 44 (36,7 por cento) foram maiores (variação de 0,5 até 4) e 20 (16,7 por cento) foram coincidentes (variação nula). Não se identificou influência da categoria profissional sobre a concordância entre os PER indicados (p = 0,899), tampouco na variabilidade observada (p = 0,778). Observou-se, contudo, que profissionais com maior tempo de experiência em unidades de cuidados intensivos demonstraram uma tendência a maior variabilidade com as medidas dos avaliadores. CONCLUSÃO: Verificou-se variabilidade nas indicações da linha axilar média como PER entre os profissionais e o avaliador treinado. A variabilidade não foi influenciada pela categoria profissional e quanto maior o tempo de experiência do profissional, maior...


OBJECTIVE: To investigate the variability in the establishment of the midaxillary line as external reference point (ERP), by different healthcare workers, for the measurement of central venous pressure in children. METHODS: Descriptive and correlational study carried out in a pediatric intensive care unit of a teaching hospital. During the establishment of the midaxillary line as ERP for central venous pressure measurement, five assessments of the same patient made by healthcare workers and one assessment made by a trained evaluator were compared. A total of 120 assessments were made by 44 healthcare workers, 17 (38.6 percent) by nursing assistants and nursing technicians, 16 (36.3 percent) by nurses and 11 (25.1 percent) by physicians, in addition to 24 assessments made by the trained evaluator. The data were analyzed using the chi-square test, ANOVA, Kruskal-Wallis test and t test. Significance level was set at 5 percent. RESULTS: There was statistically significant difference between the assessments made by healthcare workers and by the evaluator (p < 0.001). The comparison of the variability in the measurements made by healthcare workers revealed that 56 (46.7 percent) measurements were lower than those obtained by the evaluator (range from -0.5 to -9), 44 (36.7 percent) were higher (range from 0.5 to 4) and 20 (16.7 percent) were concordant (zero variability). Professional category did not influence the concordance between the ERPs (p = 0.899), or the variability observed (p = 0.778). However, the measurements made by professionals with greater experience in intensive care tended to differ more sharply from those made by the evaluators. CONCLUSION: The indications of the midaxillary line as ERP presented variations when measured by the healthcare team and by the trained evaluator. Variability was not influenced by professional category, and the more experienced the healthcare worker, the greater the probability for underestimation of the ERP...


Assuntos
Criança , Pré-Escolar , Humanos , Lactente , Veia Axilar/fisiologia , Determinação da Pressão Arterial/normas , Pressão Venosa Central/fisiologia , Análise de Variância , Distribuição de Qui-Quadrado , Pessoal de Saúde/normas , Unidades de Terapia Intensiva Pediátrica , Padrões de Referência , Estatísticas não Paramétricas
8.
J Pediatr (Rio J) ; 82(5): 389-94, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16960639

RESUMO

OBJECTIVE: To investigate the variability in the establishment of the midaxillary line as external reference point (ERP), by different healthcare workers, for the measurement of central venous pressure in children. METHODS: Descriptive and correlational study carried out in a pediatric intensive care unit of a teaching hospital. During the establishment of the midaxillary line as ERP for central venous pressure measurement, five assessments of the same patient made by healthcare workers and one assessment made by a trained evaluator were compared. A total of 120 assessments were made by 44 healthcare workers, 17 (38.6%) by nursing assistants and nursing technicians, 16 (36.3%) by nurses and 11 (25.1%) by physicians, in addition to 24 assessments made by the trained evaluator. The data were analyzed using the chi-square test, ANOVA, Kruskal-Wallis test and t test. Significance level was set at 5%. RESULTS: There was statistically significant difference between the assessments made by healthcare workers and by the evaluator (p < 0.001). The comparison of the variability in the measurements made by healthcare workers revealed that 56 (46.7%) measurements were lower than those obtained by the evaluator (range from -0.5 to -9), 44 (36.7%) were higher (range from 0.5 to 4) and 20 (16.7%) were concordant (zero variability). Professional category did not influence the concordance between the ERPs (p = 0.899), or the variability observed (p = 0.778). However, the measurements made by professionals with greater experience in intensive care tended to differ more sharply from those made by the evaluators. CONCLUSION: The indications of the midaxillary line as ERP presented variations when measured by the healthcare team and by the trained evaluator. Variability was not influenced by professional category, and the more experienced the healthcare worker, the greater the probability for underestimation of the ERP. According to the results of this study, such situations may compromise both the efficacy of this procedure and patient safety.


Assuntos
Veia Axilar/fisiologia , Determinação da Pressão Arterial/normas , Pressão Venosa Central/fisiologia , Análise de Variância , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Pessoal de Saúde/normas , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Padrões de Referência , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...