Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 12(11)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36362940

RESUMO

The blood-brain barrier (BBB) is likely to be intact during the early stages of brain metastatic melanoma development, and thereby inhibits sufficient drug delivery into the metastatic lesions. Our laboratory has been developing a system for boron drug delivery to brain cells via cerebrospinal fluid (CSF) as a viable pathway to circumvent the BBB in boron neutron capture therapy (BNCT). BNCT is a cell-selective cancer treatment based on the use of boron-containing drugs and neutron irradiation. Selective tumor targeting by boron with minimal normal tissue toxicity is required for effective BNCT. Boronophenylalanine (BPA) is widely used as a boron drug for BNCT. In our previous study, we demonstrated that application of the CSF administration method results in high BPA accumulation in the brain tumor even with a low dose of BPA. In this study, we evaluate BPA biodistribution in the brain following application of the CSF method in brain-tumor-model rats (melanoma) utilizing matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI). We observed increased BPA penetration to the tumor tissue, where the color contrast on mass images indicates the border of BPA accumulation between tumor and normal cells. Our approach could be useful as drug delivery to different types of brain tumor, including brain metastases of melanoma.

2.
Appl Radiat Isot ; 185: 110226, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35533616

RESUMO

The purpose of this study is to develop a portable monitor that can measure the energy spectrum and dose of gamma-rays simultaneously in real time for the benefit of medical staff who must work in clinical radiation environments. For this purpose, we have developed a prototype monitor using a CsI (Tl) scintillator combined with a multi-pixel photon counter (MPPC). For real-time measurement, we employed an improved sequential Bayesian estimation (k-α method) to convert the measured pulse height spectrum into an energy spectrum. Then we confirmed that reconstruction of the energy spectrum and dose estimation could simultaneously be carried out in real time by the k-α method in a radiation field composed of mixed standard gamma-ray sources. In this study, we carried out measurements in a background gamma-ray field to confirm applicability of the prototype monitor to the weakest type of radiation field. In addition, we conducted measurements in front of a nuclear fuel storage room (∼2 µSv/h) in the authors' laboratory to evaluate practicality of the monitor for measuring fields with a complex energy spectrum. As a result, it was found that the dose could be estimated in about 20 s after start of measurements even in the background field. For the energy spectrum, it was instantly reconstructed within 60 s in front of the fuel storage room. On the other hand, it could successfully be estimated within 10 min in the background gamma-ray field. Currently, the convergence of the energy spectrum is determined visually from time dependent change of the spectrum and dose. As a next step, we will attempt to develop a more quantitative procedure for determining the convergence.


Assuntos
Fótons , Teorema de Bayes , Raios gama , Humanos
3.
Res Vet Sci ; 148: 1-6, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35523003

RESUMO

Boron neutron capture therapy (BNCT) is a non-invasive type of radiation therapy developed for humans and translated to veterinary medicine. However, clinical trials on BNCT for patients with brain tumors are on-going. To improve the therapeutic efficacy of BNCT for brain tumors, we developed a boron delivery system that involves the cerebrospinal fluid (CSF), in contrast to the conventional method that involves intravenous (IV) administration. This study aimed to investigate the time-concentration profile of boron in the CSF as well as the uptake rate of boron by the brain cells after administering L-p­boronophenylalanine (BPA) into the lateral ventricle of normal rats. Brain cell uptake rates were compared between the CSF-based and IV administration methods. The CSF-based and IV administration methods achieved comparable brain cell uptake levels; however, the former method involved lower BPA doses than the latter method. These findings suggest that the CSF method may reduce the economic and physical burdens associated with this treatment in brain tumor patients. Future studies should validate these findings in rat models of brain tumors.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Doenças dos Roedores , Animais , Boro/uso terapêutico , Compostos de Boro/uso terapêutico , Terapia por Captura de Nêutron de Boro/métodos , Terapia por Captura de Nêutron de Boro/veterinária , Encéfalo , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/veterinária , Humanos , Ratos
4.
Biology (Basel) ; 11(3)2022 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-35336771

RESUMO

Recently, exploitation of cerebrospinal fluid (CSF) circulation has become increasingly recognized as a feasible strategy to solve the challenges involved in drug delivery for treating brain tumors. Boron neutron capture therapy (BNCT) also faces challenges associated with the development of an efficient delivery system for boron, especially to brain tumors. Our laboratory has been developing a system for boron delivery to brain cells using CSF, which we call the "boron CSF administration method". In our previous study, we found that boron was efficiently delivered to the brain cells of normal rats in the form of small amounts of L-p-boronophenylalanine (BPA) using the CSF administration method. In the study described here, we carried out experiments with brain tumor model rats to demonstrate the usefulness of the CSF administration method for BNCT. We first investigated the boron concentration of the brain cells every 60 min after BPA administration into the lateral ventricle of normal rats. Second, we measured and compared the boron concentration in the melanoma model rats after administering boron via either the CSF administration method or the intravenous (IV) administration method, with estimation of the T/N ratio. Our results revealed that boron injected by the CSF administration method was excreted quickly from normal cells, resulting in a high T/N ratio compared to that of IV administration. In addition, the CSF administration method resulted in high boron accumulation in tumor cells. In conclusion, we found that using our developed CSF administration method results in more selective delivery of boron to the brain tumor compared with the IV administration method.

5.
Appl Radiat Isot ; 181: 110056, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34953318

RESUMO

Boron Neutron Capture Therapy (BNCT) is a promising cancer therapy, which has recently been in practical use in Japan especially using an accelerator. In BNCT real-time measurement of local boron dose is required. In the present study, a novel design of a SPECT system for BNCT (BNCT-SPECT) has been carried out to realize estimation of the local boron dose, i.e., treatment effect of BNCT. Necessary performance which BNCT community requires includes accuracy of 5% and spatial resolution of 5 mm, which are regarded to be difficult to realize. A possible design was investigated to meet the requirements. The design results we achieved are as follows: As for the elemental detection device, GAGG (3.5 × 3.5 × 30 mm3) was selected, and for the collimator, the collimator hole diameter was 3.5 mm, the collimator hole pitch was 4 mm and the collimator length was 26 cm. For the obtained performance with the design, the accuracy was 4.4% and the spatial resolution was 5.1 mm. Currently prior to production of the real system, a prototype of BNCT-SPECT is being developed to acquire real projection data to confirm the performance and examine our own image reconstruction method with the obtained projection data.


Assuntos
Compostos de Boro/administração & dosagem , Terapia por Captura de Nêutron de Boro , Contagem de Cintilação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Aceleradores de Partículas , Dosagem Radioterapêutica , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
Mass Spectrom (Tokyo) ; 11(1): A0105, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36713803

RESUMO

Boron neutron capture therapy (BNCT) is a cell-selective particle therapy for cancer using boron containing drugs. Boron compounds are accumulated in high concentration of tens ppm level of boron in target tumors to cause lethal damage to tumor tissue. The examination of boron distribution in target tumor and normal tissue is important to evaluate the efficiency of therapy. The matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is a powerful tool to visualize the distribution of target analyte in biological samples. In this manuscript, we report a trial to visualize the distribution of a typical BNCT drug, L-4-phenylalanine boronic acid (BPA) in a brain tumor model rat using MALDI-MSI technique. We performed a MALDI-MSI with high mass resolution targeting to [BPA+H]+ at m/z 210 in a BPA-treated rat brain section using a spiral orbit-type time of flight (SpiralTOF) mass spectrometer. Several BPA ion species, [BPA+H]+, [BPA-H2O+Na]+, [BPA+DHB-2H2O+Na]+ and [BPA+DHB-2H2O+K]+ were detected separate from peaks originated from biomolecules or matrix reagent by achieving the mass resolving power of approximately 20,000 (full width at half maximum; FWHM) at m/z 210. The mass images with 60 µm spatial resolution obtained from these BPA ion species in a mass window of 0.02 Da revealed their localization in the tumor region. Additionally, the mass image obtained from [BPA+H]+ also likely showed the distribution of BPA inside the tumor. MALDI-MSI with high mass resolution targeting to [BPA+H]+ has a great potential to visualize the distribution of BPA in brain tissue with tumor.

7.
Appl Radiat Isot ; 151: 145-149, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31177072

RESUMO

Based on the activation method using 71Ga(n,γ)72Ga reaction, a cubic neutron flux intensity detector for epi-thermal neutrons was designed for boron neutron capture therapy (BNCT), and experimentally tested with a prototype detector in a neutron field produced at OKTAVIAN facility of Osaka University, Japan. The experimental test results and related analysis indicated that the performance of the detector was confirmed to be acceptable in the neutron field of BNCT. Practically, the neutron flux intensity mainly covering from 0.5 eV to 10 keV can be measured within 3% by the present detector.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Isótopos de Gálio/química , Radioisótopos de Gálio/química , Nêutrons
8.
Radiat Prot Dosimetry ; 180(1-4): 300-303, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29088420

RESUMO

Boron neutron capture therapy is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to measure the neutron spectrum in the treatment field is not well established. Many researchers are making efforts to improve the spectrometers. To solve this problem, we are developing a liquid-moderator-based neutron spectrometer that is based on the same theory as that of the Bonner sphere spectrometer. The spectrometer uses a liquid moderator and absorber. In the present study, we performed a design study to improve the previously developed liquid-moderator-based neutron spectrometer. By carrying out a numerical simulation of the designed new spectrometer, we finally assessed and confirmed the validity of this spectrometer numerically.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Modelos Teóricos , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Desenho de Equipamento , Humanos , Dosagem Radioterapêutica
9.
Radiat Prot Dosimetry ; 177(4): 475-480, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28498969

RESUMO

A novel optically stimulated luminescence (OSL) detector containing isotopically enriched boron was developed for thermal neutron dosimetry. Alumina containing isotopically enriched boron (Al2O3:B) was synthesised by the sol-gel method. The Al2O3:B was annealed up to ~1800 K. For X-ray diffractometer (XRD) analysis, the diffraction pattern of the Al2O3:B had reflex peaks corresponding to α-Al2O3. The sensitivity of Al2O3:B to photons was slightly 2% of that of a commercial Al2O3:C. The Al2O3:B detector had satisfactory linearity in X-ray dose measurement. A thermal neutron field was constructed using a 241Am-Be neutron source and graphite blocks. A pair of Al2O3:10B and Al2O3:11B detectors were set in the thermal neutron field. The response of Al2O3:10B was larger than that of Al2O3:11B owing to the 10B(n,α)7Li reactions. The sensitivity of Al2O3:10B to thermal neutrons was estimated to be two orders less than the photon sensitivity. Therefore, the pair of Al2O3:10B and Al2O3:11B detectors were useful for thermal neutron dosimetry.


Assuntos
Óxido de Alumínio/química , Boro/química , Nêutrons , Dosímetros de Radiação , Desenho de Equipamento , Fótons , Sensibilidade e Especificidade , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...