Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(1)2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38203243

RESUMO

Small extracellular vesicles (sEVs) contain microRNAs (miRNAs) which have potential to act as disease-specific biomarkers. The current study uses an established method to maintain human thyroid tissue ex vivo on a tissue-on-chip device, allowing the collection, isolation and interrogation of the sEVs released directly from thyroid tissue. sEVs were analysed for differences in miRNA levels released from benign thyroid tissue, Graves' disease tissue and papillary thyroid cancer (PTC), using miRNA sequencing and quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) to identify potential biomarkers of disease. Thyroid biopsies from patients with benign tissue (n = 5), Graves' disease (n = 5) and PTC (n = 5) were perfused with medium containing sEV-depleted serum for 6 days on the tissue-on-chip device. During incubation, the effluents were collected and ultracentrifuged to isolate sEVs; miRNA was extracted and sequenced (miRNASeq). Out of the 15 samples, 14 passed the quality control and miRNASeq analysis detected significantly higher expression of miR-375-3p, miR-7-5p, miR-382-5p and miR-127-3p in the sEVs isolated from Graves' tissue compared to those from benign tissue (false discovery rate; FDR p < 0.05). Similarly, miR-375-3p and miR-7-5p were also detected at a higher level in the Graves' tissue sEVs compared to the PTC tissue sEVs (FDR p < 0.05). No significant differences were observed between miRNA in sEVs from PTC vs. those from benign tissue. These results were supported by Quantitative Reverse Transcriptase Polymerase Chain Reaction (qRT-PCR). The novel findings demonstrate that the tissue-on-chip technology is a robust method for isolating sEVs directly from the tissue of interest, which has permitted the identification of four miRNAs, with which further investigation could be used as biomarkers or therapeutic targets within thyroid disease.


Assuntos
Vesículas Extracelulares , Doença de Graves , MicroRNAs , Doenças da Glândula Tireoide , Neoplasias da Glândula Tireoide , Humanos , MicroRNAs/genética , Doenças da Glândula Tireoide/diagnóstico , Doenças da Glândula Tireoide/genética , Controle de Qualidade , Biomarcadores , Vesículas Extracelulares/genética , Câncer Papilífero da Tireoide
2.
Oncol Lett ; 22(5): 780, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34594421

RESUMO

Although a large cohort of potential biomarkers for thyroid cancer aggressiveness have been tested in various formats in recent years, to the best of our knowledge, thyroglobulin and calcitonin remain the only two established biomarkers associated with thyroid cancer management. Our group has recently validated a novel means of maintaining live, human ex vivo thyroid tissue within a tissue-on-chip format. The present pilot study aimed to interrogate the tissue effluent, containing all the soluble markers released by the tissue samples maintained within the devices' tissue chamber, for the presence of markers potentially associated with thyroid cancer aggressiveness. Culture effluent from tissue samples harvested from 19 individual patients who had undergone thyroidectomy for the treatment of suspected thyroid cancer was assessed, first using a proteome profiler™ angiogenesis array kit. Patients were subcategorised as 'aggressive' if they possessed a minimum of N1b level metastases, whilst 'non-aggressive' samples were T3 or lower without evidence of multifocality; and contralateral healthy thyroid tissue was harvested for comparative studies. Levels of Serpin-F1, vascular endothelial growth factor, Thrombospondin-1 and chemokine (C-C motif) ligand were significantly altered and, thus, were further investigated using ELISA to allow for quantitative analysis. The concentration of serpin-F1 was significantly increased in the effluent of aggressive thyroid cancer tissue when compared with levels released by both non-aggressive and benign samples. The present study demonstrated the usability of microfluidic technology for the analysis of the ex vivo tissue secretome in order to identify novel biomarkers.

3.
Biotechniques ; 65(1): 37-39, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30014737

RESUMO

Calcium dynamics is crucial for many signaling pathways and cell functions. Understanding how calcium regulates cell function often requires long-term imaging of calcium dynamics. Here we report a methodological approach of long-term (5-10 h) imaging of calcium dynamics in cultured cells. The approach links calcium imaging using genetically encoded calcium indicators and semi-automatic tracking of individual cells. It can be used in a large variety of situations, ranging from the role of calcium in biological processes to cell heterogeneity and screening of drugs modifying signaling pathways.


Assuntos
Cálcio/metabolismo , Rastreamento de Células/métodos , Células Cultivadas , Genes Reporter , Células HeLa , Humanos , Indicadores e Reagentes , Microscopia de Contraste de Fase , Simulação de Dinâmica Molecular , Imagem Óptica , Fatores de Tempo
4.
Front Microbiol ; 9: 678, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29675015

RESUMO

There has been a steady rise in the incidences of algal blooms globally, and worryingly, there is increasing evidence that changes in the global climate are leading to a shift toward cyanobacterial blooms. Many cyanobacterial genera are harmful, producing several potent toxins, including microcystins, for which there are over 90 described analogues. There are a wide range of negative effects associated with these toxins including gastroenteritis, cytotoxicity, hepatotoxicity and neurotoxicity. Although a variety of oxidation based treatment methods have been described, ozonation and advanced oxidation are acknowledged as most effective as they readily oxidise microcystins to non-toxic degradation products. However, most ozonation technologies have challenges for scale up including high costs and sub-optimum efficiencies, hence, a low cost and scalable ozonation technology is needed. Here we designed a low temperature plasma dielectric barrier discharge (DBD) reactor with an incorporated fluidic oscillator for microbubble delivery of ozone. Both technologies have the potential to drastically reduce the costs of ozonation at scale. Mass spectrometry analysis revealed very rapid (<2 min) destruction of two pure microcystins (MC-LR and MC-RR), together with removal of by-products even at low flow rate 1 L min-1 where bubble size was 0.56-0.6 mm and the ozone concentration within the liquid was 20 ppm. Toxicity levels were calculated through protein phosphatase inhibition assays and indicated loss of toxicity as well as confirming the by-products were also non-toxic. Finally, treatment of whole Microcystis aeruginosa cells showed that even at these very low ozone levels, cells can be killed and toxins (MC-LR and Desmethyl MC-LR) removed. Little change was observed in the first 20 min of treatment followed by rapid increase in extracellular toxins, indicating cell lysis, with most significant release at the higher 3 L min-1 flow rate compared to 1 L min-1. This lab-scale investigation demonstrates the potential of the novel plasma micro reactor with applications for in situ treatment of harmful algal blooms and cyanotoxins.

5.
Future Sci OA ; 3(2): FSO174, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28670466

RESUMO

AIM: Head and neck squamous cell carcinomas (HNSCC) are solid tumors with low overall survival (40-60%). In a move toward personalized medicine, maintenance of tumor biopsies in microfluidic tissue culture devices is being developed. METHODOLOGY/RESULTS: HNSCC (n = 15) was dissected (5-10 mg) and either analyzed immediately or cultured in a microfluidic device (37°C) for 48 h. No difference was observed in morphology between pre- and postculture specimens. Dissociated samples were analyzed using trypan blue exclusion (viability), propidium iodide flow cytometry (death) and MTS assay (proliferation) with no significant difference observed highlighting tissue maintenance. Computational fluid dynamics showed laminar flow within the system. CONCLUSION: The microfluidic culture system successfully maintained HNSCC for 48 h, the culture system will allow testing of different treatment modalities with response monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...