1.
J Magn Reson ; 168(2): 252-8, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15140435

RESUMO

We report a difference in the spectral lineshapes of continuous-wave (CW) electron paramagnetic resonance (EPR) spectroscopy between field and frequency modulation. This finding addresses the long-standing question of the effect of modulation in EPR absorption. We compared the first-derivative EPR spectra at 1.1 GHz for lithium phthalocyanine crystals, which have a single narrow linewidth in the EPR absorption spectrum, using field and frequency modulation. The experimental findings suggest that unpaired electrons have different behaviors under perturbation due to field and frequency modulation.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Indóis/análise , Indóis/química , Micro-Ondas , Compostos Organometálicos/análise , Compostos Organometálicos/química , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Elétrons , Desenho de Equipamento , Análise de Falha de Equipamento
2.
J Magn Reson ; 164(2): 233-41, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14511592

RESUMO

A frequency modulation (FM) method was developed to measure electron paramagnetic resonance (EPR) absorption. The first-derivative spectrum of 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder was measured with this FM method. Frequency modulation of up to 1.6 MHz (peak-to-peak) was achieved at a microwave carrier frequency of 1.1 GHz. This corresponds to a magnetic field modulation of 57microT (peak-to-peak) at 40.3 mT. By using a tunable microwave resonator and automatic control systems, we achieved a practical continuous-wave (CW) EPR spectrometer that incorporates the FM method. In the present experiments, the EPR signal intensity was proportional to the magnitude of frequency modulation. The background signal at the modulation frequency (1 kHz) for EPR detection was also proportional to the magnitude of frequency modulation. An automatic matching control (AMC) system reduced the amplitude of noise in microwave detection and improved the baseline stability. Distortion of the spectral lineshape was seen when the spectrometer settings were not appropriate, e.g., with a lack of the open-loop gain in automatic tuning control (ATC). FM is an alternative to field modulation when the side-effect of field modulation is detrimental for EPR detection. The present spectroscopic technique based on the FM scheme is useful for measuring the first derivative with respect to the microwave frequency in investigations of electron-spin-related phenomena.


Assuntos
Compostos de Bifenilo/química , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Retroalimentação , Hidrazinas/química , Magnetismo/instrumentação , Ondas de Rádio , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Micro-Ondas , Picratos , Controle de Qualidade