Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Clin Lab Anal ; 38(6): e25027, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38506403

RESUMO

BACKGROUND: Assessment of bone marrow involvement (BMI) in non-Hodgkin lymphoma (NHL) is crucial for determining patient prognosis and treatment strategy. We assessed the prognostic value of next-generation sequencing (NGS)-based immunoglobulin (Ig) gene clonality analysis as an ancillary test for BMI evaluation in NHL. METHODS: A retrospective cohort of 124 patients newly diagnosed with B-cell NHL between 2019 and 2022 was included. NGS-based Ig clonality analysis was conducted using LymphoTrak IGH FR1 Assay and IGK Assay (Invivoscribe Technologies, San Diego, CA, USA) on BM aspirate samples, and the results were compared with those of histopathological BMI (hBMI). RESULTS: Among the 124 patients, hBMI was detected in 16.9% (n = 21). The overall agreement of BMI between Ig clonality analyses and histopathological analysis for IGH, IGK, and either IGH or IGK was 86.3%, 92.7%, and 90.3%. The highest positive percent agreement was observed with clonal rearrangements of either IGH or IGK gene (90.5%), while the highest negative percent agreement was observed with clonal rearrangement of IGK gene (96.1%). For the prediction of hBMI, positive prediction value ranged between 59.1% and 80.0% and the negative prediction value ranged between 91.3% and 97.9%. CONCLUSION: NGS-based clonality analysis is an analytic platform with a substantial overall agreement with histopathological analysis. Assessment of both IGH and IGK genes for the clonal rearrangement analysis could be considered for the optimal diagnostic performance of BMI detection in B-cell NHL.


Assuntos
Linfoma de Células B , Linfoma não Hodgkin , Humanos , Genes de Imunoglobulinas , Medula Óssea/patologia , Estudos Retrospectivos , Linfoma de Células B/genética , Linfoma de Células B/diagnóstico , Linfoma de Células B/patologia , Linfoma não Hodgkin/genética , Sequenciamento de Nucleotídeos em Larga Escala
2.
Cancers (Basel) ; 15(21)2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37958462

RESUMO

Complex karyotype (CK) is associated with a poor prognosis in both acute myeloid leukemia (AML) and myelodysplastic syndrome with excess blasts (MDS-EB). Transcriptomic analyses have improved our understanding of the disease and risk stratification of myeloid neoplasms; however, CK-specific gene expression signatures have been rarely investigated. In this study, we developed and validated a CK-specific gene expression signature. Differential gene expression analysis between the CK and non-CK groups using data from 348 patients with AML and MDS-EB from four cohorts revealed enrichment of the downregulated genes localized on chromosome 5q or 7q, suggesting that haploinsufficiency due to the deletion of these chromosomes possibly underlies CK pathogenesis. We built a robust transcriptional model for CK prediction using LASSO regression for gene subset selection and validated it using the leave-one-out cross-validation method for fitting the logistic regression model. We established a 10-gene CK signature (CKS) predictive of CK with high predictive accuracy (accuracy 94.22%; AUC 0.977). CKS was significantly associated with shorter overall survival in three independent cohorts, and was comparable to that of previously established risk stratification models for AML. Furthermore, we explored of therapeutic targets among the genes comprising CKS and identified the dysregulated expression of superoxide dismutase 1 (SOD1) gene, which is potentially amenable to SOD1 inhibitors.

3.
Ann Lab Med ; 43(5): 503-507, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37080752

RESUMO

The fifth edition of the WHO classification (2022 WHO) and the International Consensus Classification (2022 ICC) of myeloid neoplasms have been recently published. We reviewed the changes in the diagnosis distribution in patients with MDS with excess blasts (MDS-EB) or AML using both classifications. Forty-seven patients previously diagnosed as having AML or MDS-EB with available mutation analysis data, including targeted next-generation and RNA-sequencing data, were included. We reclassified 15 (31.9%) and 27 (57.4%) patients based on the 2022 WHO and 2022 ICC, respectively. One patient was reclassified as having a translocation categorized as a rare recurring translocation in both classifications. Reclassification was mostly due to the addition of mutation-based diagnostic criteria (i.e., AML, myelodysplasia-related) or a new entity associated with TP53 mutation. In both classifications, MDS diagnosis required the confirmation of multi-hit TP53 alterations. Among 14 patients with TP53 mutations, 11 harbored multi-hit TP53 alterations, including four with TP53 mutations and loss of heterozygosity. Adverse prognosis was associated with multi-hit TP53 alterations (P=0.009) in patients with MDS-EB, emphasizing the importance of detecting the mutations at diagnosis. The implementation of these classifications may lead to the identification of different subtypes from previously heterogeneous diagnostic categories based on genetic characteristics.


Assuntos
Leucemia Mieloide Aguda , Síndromes Mielodisplásicas , Transtornos Mieloproliferativos , Humanos , Consenso , Síndromes Mielodisplásicas/diagnóstico , Síndromes Mielodisplásicas/genética , Leucemia Mieloide Aguda/diagnóstico , Leucemia Mieloide Aguda/genética , Mutação , Organização Mundial da Saúde
4.
Mol Syndromol ; 13(4): 318-322, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36158052

RESUMO

Background: PHF21A, along with EXT2 and ALX4, is one of the causative genes of Potocki-Shaffer syndrome (PSS), a rare contiguous disorder involving chromosome region11p11.2. PHF21A has been associated with intellectual developmental disorders and craniofacial anomalies and suggested as a candidate for more extended phenotypes. However, variants in PHF21A and its associated phenotypes are yet to be fully explored, since reports on cases with variants affecting this gene are few worldwide. We present a novel heterogeneous variant in PHF21A in a 26-year-old Korean female. Methods: The patient's clinical manifestations were recorded and physical examination, cognitive assessment, brain imaging, metabolic screening, and cytogenetic testing including whole exome sequencing were pursued. Results: Whole exome sequencing identified a de novo nonsense variant c.1171A>T (p.Lys391Ter), affecting the AT-hook domain. The patient showed an extended phenotypic spectrum along with intellectual developmental disorders and craniofacial anomalies, such as attention-deficit hyperactivity disorder, epilepsy, overgrowth, and hypotonia. Variants affecting the AT-hook domain are few in PSS, however, the phenotypic spectrum of the patient was in line with previously reported cases. Conclusion: This case further reinforced and adds to the extended data on the phenotypes associated with PHF21A haploinsufficiency.

5.
Artigo em Inglês | MEDLINE | ID: mdl-35270497

RESUMO

Therapeutic goals for hemiplegic patients with neurological impairments are mainly focused on improving their independent lives. Based on the previously reported effectiveness of Wii Fit balance training, this study investigated the most influential outcomes after long-term intensive training (including balance and functional factors) on quality of life in hemiplegic patients. The intervention group (n = 21) received Nintendo Wii Fit balance training under supervision, and control group (n = 20) received conventional balance training by an occupational therapist. Two groups were matched based on age and onset duration. Both groups received a total of 15 treatments for 30 min per session, twice a week for 8 weeks. There were significant improvements not only in balance confidence and activities of daily living, but also in body composition, such as fat proportion and metabolic rate, in the intervention group compared to the control group (p < 0.05). In particular, balance confidence significantly affected EuroQoL Visual Analogue Scale according to stepwise multiple regression analyses in this study. These results demonstrated that Wii Fit balance training using virtual reality improved the quality of life of hemiplegic patients while overcoming the asymmetrical weight distribution of the affected side via the self-modulating biofeedback exercises.


Assuntos
Jogos de Vídeo , Realidade Virtual , Atividades Cotidianas , Terapia por Exercício/métodos , Hemiplegia , Humanos , Equilíbrio Postural , Qualidade de Vida
6.
Ann Lab Med ; 41(1): 44-50, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32829578

RESUMO

BACKGROUND: The Advanced RBC Application of the CellaVision DM9600 system (CellaVision AB, Lund, Sweden) automatically characterizes and classifies red blood cells (RBCs) into 21 morphological categories based on their size, color, shape, and inclusions. We evaluated the diagnostic performance of the CellaVision Advanced RBC Application with respect to the classification and grading of RBC morphological abnormalities in accordance with the 2015 International Council for Standardization in Haematology (ICSH) guidelines. METHODS: A total of 223 samples, including 123 with RBC morphological abnormalities and 100 from healthy controls, were included. Seven RBC morphological abnormalities and their grading obtained with CellaVision DM9600 pre- and post-classification were compared with the results obtained using manual microscopic examination. The grading cut-off percentages were determined in accordance with the 2015 ICSH guidelines. The sensitivity and specificity of the CellaVision DM9600 system were evaluated using the manual microscopic examination results as a true positive. RESULTS: In pre-classification, >90% sensitivity was observed for target cells, tear drop cells, and schistocytes, while >90% specificity was observed for acanthocytes, spherocytes, target cells, and tear drop cells. In post-classification, the detection sensitivity and specificity of most RBC morphological abnormalities increased, except for schistocytes (sensitivity) and acanthocytes (specificity). The grade agreement rates ranged from 35.9% (echinocytes) to 89.7% (spherocytes) in pre-classification and from 46.2% (echinocytes) to 90.1% (spherocytes) in post-classification. The agreement rate of samples with within-one grade difference exceeded 90% in most categories, except for schistocytes and echinocytes. CONCLUSIONS: The Advanced RBC Application of CellaVision DM9600 is a valuable screening tool for detecting RBC morphological abnormalities.


Assuntos
Eritrócitos Anormais/citologia , Microscopia/métodos , Acantócitos/classificação , Acantócitos/citologia , Área Sob a Curva , Estudos de Casos e Controles , Eritrócitos Anormais/classificação , Humanos , Microscopia/instrumentação , Curva ROC , Estudos Retrospectivos , Esferócitos/classificação , Esferócitos/citologia
8.
Acta Trop ; 193: 7-11, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30768978

RESUMO

Microscopic examination of blood smears is the standard method for malaria diagnosis but is labor-intensive and requires expert staff. CellaVision DM96 (CellaVision, Lund, Sweden) is a digital hematology analyzer available for advanced morphological analysis of blood films including intracellular parasites. Here, we evaluated the CellaVision DM96 Advanced RBC Application for malaria detection in stained peripheral blood (PB) smears. Two hundred and twenty thin PB smear slides (84 P. vivax, 14 P. falciparum, 122 negative controls) were stained with Wright-Giemsa using automated slidemaker/strainers of Beckman Coulter hematology systems (LH780, Beckman Coulter Inc., Miami, FL). The slides were automatically analyzed by CellaVision, and images were manually reviewed by experts. The results of automatic and manual detection by CellaVision were compared to those of microscopic examination. The sensitivity and specificity of automatic detection by CellaVision were 23.5% (23/98) and 81.1% (99/122), respectively. When CellaVision images were manually reviewed, the sensitivity and specificity increased to 65.3% (64/98) and 90.2% (110/122), respectively. The detection of P. falciparum showed the highest sensitivity by both the automated (33.3%) and the manual (85.7%) method. CellaVision misinterpreted malaria parasites as Howell-Jolly bodies in 57.1%, as Pappenheimer bodies in 84.7%, and as basophilic stipplings in 75.5% of the slides. Malaria diagnosis using CellaVision DM96 requires further improvements. Manual review improves CellaVision performance, but confirmation by conventional microscopy remains essential.


Assuntos
Testes Diagnósticos de Rotina/instrumentação , Malária Falciparum/diagnóstico , Malária Vivax/diagnóstico , Plasmodium falciparum , Plasmodium vivax , Humanos , Malária Falciparum/sangue , Malária Vivax/sangue , Microscopia , Sensibilidade e Especificidade
9.
Ann Lab Med ; 38(6): 512-517, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30027693

RESUMO

BACKGROUND: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. METHODS: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. RESULTS: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. CONCLUSIONS: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations.


Assuntos
Contagem de Células Sanguíneas , Software , Humanos , Sistemas Computadorizados de Registros Médicos
10.
BJU Int ; 103(12): 1721-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19154479

RESUMO

OBJECTIVE: To determine the genetic alterations and chemosensitivity profile of collecting duct carcinoma (CDC) of the kidney, as it is a rare, highly aggressive malignant tumour with frequent distant metastases. MATERIALS AND METHODS: We first established and characterized two human CDC cell lines designated AP3 and AP8, respectively. The CDC cell lines were assessed using microarray-based comparative genomic hybridization and chemosensitivity testing. RESULTS: The CDC cells grew in vitro as an adherent monolayer with epithelial morphology, but had different growth rates. The cell lines had the characteristic immunophenotype of CDC (high molecular weight cytokeratin-+ve/cytokeratin 7-+ve/vimentin-+ve). Both cell lines shared copy number gains in chromosomes 20 and X. The loci showing a copy number gain were SOX22 at 20p tel, topoisomerse I (TOP1) at 20q12-q13.1, TPD52L2 at 20q tel, 20QTEL14 at 20q tel, KAL at Xp22.3, STS 5' at Xp22.3, OCRL1 at Xq25, AR3'at Xq11-q12, and XIST at Xq13.2, respectively. Immunoblot analysis confirmed that the AP3 and AP8 cell lines showed moderate and high levels of TOP1 expression, respectively. By chemosensitivity testing, the AP8 cells were most sensitive to topoisomerase I and II inhibitors such as topotecan, epirubicin and doxorubicin, but the AP3 cells did not. The chemosensitivity to these drugs was paralleled by cell death via apoptosis. CONCLUSION: The results suggest that TOP1 might be one of the molecular targets in AP8 CDC cells. Thus, these novel CDC cell lines will be useful for discovering therapeutic targets and developing effective anticancer drugs against CDC.


Assuntos
Carcinoma de Células Renais/genética , Neoplasias Renais/genética , Túbulos Renais Coletores , Idoso , Western Blotting , Carcinoma de Células Renais/tratamento farmacológico , Linhagem Celular Tumoral , Hibridização Genômica Comparativa , DNA Topoisomerases Tipo I/genética , Feminino , Humanos , Imuno-Histoquímica , Neoplasias Renais/tratamento farmacológico , Masculino , Pessoa de Meia-Idade
11.
J Korean Med Sci ; 23(4): 711-3, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18756062

RESUMO

Standardization of medical terminology is essential in data transmission between health care institutes and in maximizing the benefits of information technology. The purpose of this study was to standardize medical terms for laboratory observations. During the second year of the study, a standard database of concept names for laboratory terms that covered those used in tertiary health care institutes and reference laboratories was developed. The laboratory terms in the Logical Observation Identifier Names and Codes (LOINC) database were adopted and matched with the electronic data interchange (EDI) codes in Korea. A public hearing and a workshop for clinical pathologists were held to collect the opinions of experts. The Korean standard laboratory terminology database containing six axial concept names, components, property, time aspect, system (specimen), scale type, and method type, was established for 29,340 test observations. Short names and mapping tables for EDI codes and UMLS were added. Synonym tables were prepared to help match concept names to common terms used in the fields. We herein described the Korean standard laboratory terminology database for test names, result description terms, and result units encompassing most of the laboratory tests in Korea.


Assuntos
Sistemas de Informação em Laboratório Clínico/normas , Técnicas de Laboratório Clínico/normas , Logical Observation Identifiers Names and Codes , Unified Medical Language System , Humanos , Terminologia como Assunto
12.
Clin Chem ; 54(2): 424-8, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18223133

RESUMO

BACKGROUND: Hepatitis C virus (HCV) can be transmitted through blood transfusion. Screening ELISA, the most widely used method for HCV diagnosis, sometimes yields false-positive and false-negative results, so a confirmatory test is used. This secondary testing is labor-intensive and expensive, and thus is impractical for massive blood bank screening. Therefore, a new massive screening method with high accuracy is needed for sensitive and specific detection of HCV. METHODS: With sol-gel material, we designed novel antigen microarray in 96-well plates for HCV detection. Each individual well was spotted with 4 different HCV antigens. We used this new system to test 154 patient serum samples previously tested for HCV by ELISA (87 HCV positive and 67 HCV negative) (HCV EIA3.0, ABBOTT). We assessed the detection limit of our microarray system with the use of serial 10-fold dilutions of an HCV-positive sample. RESULTS: Our microarray assay was reproducible and displayed higher diagnostic accuracy (specificity) (98.78%) than did the ELISA (81.71%). Our method yielded significantly fewer false-positive results than did the ELISA. The detection limit of our assay was 1000 times more sensitive than that of the ELISA. In addition, we found this novel assay technology to be compatible with the currently employed automated methods used for ELISA. CONCLUSION: We successfully applied the sol-gel-based protein microarray technology to a screening assay for HCV diagnosis with confirmatory test-level accuracy. This new, inexpensive method will improve the specificity and sensitivity of massive sample diagnosis.


Assuntos
Antígenos Virais/análise , Hepacivirus/classificação , Hepatite C/diagnóstico , Ensaio de Imunoadsorção Enzimática , Hepatite C/virologia , Humanos , Análise Serial de Proteínas , Sensibilidade e Especificidade , Virologia/métodos
13.
Korean J Lab Med ; 27(2): 143-50, 2007 Apr.
Artigo em Coreano | MEDLINE | ID: mdl-18094567

RESUMO

BACKGROUND: A questionnaire survey was performed to perceive the problem of the current medical insurance reimbursement system for laboratory tests referred to independent medical laboratories; then, we intended to find a way to improve the reimbursement system. METHODS: Questionnaires were distributed to 220 independent medical laboratories and 700 laboratory physicians from July through October 2005. Frequency analysis was used to analyse the replies from 109 respondents to 25 questionnaire items regarding the current medical insurance reimbursement system for referral tests, problems with the system, and suggestions for the improvement of the system. RESULTS: Among the 109 respondents to this survey, 49 (45.8%) considered the current reimbursement system to be unsatisfactory, while only 16 (15.0%) answered satisfactory. The problem was that the referral clinics-not the laboratories that performed the tests--would first receive their reimbursement for the laboratory tests from Health Insurance Review Agency (HIRA) and then give a portion of the laboratory test fees to the independent medical laboratories after the deduction of administrative fees. They (62.5% of the respondents) would prefer a separated reimbursement system by which the referral clinic-as well as the independent medical laboratory-would receive their reimbursement directly from HIRA through an Electronic Data Interchange (EDI) system. In this new system, 34% of the respondents expected the quality of the laboratory tests to be improved; however, 41.6% answered that the income of the referral clinic is expected to decrease. CONCLUSIONS: For the improvement of the medical insurance reimbursement system, the administrative fee for the referral clinic and the test fee for the independent medical laboratory should be reimbursed directly to the respective organizations. These changes could be made possible with the proper analysis of medical costs and the development of an effective EDI reimbursement system.


Assuntos
Técnicas de Laboratório Clínico/economia , Reembolso de Seguro de Saúde , Feminino , Humanos , Coreia (Geográfico) , Laboratórios Hospitalares/economia , Masculino , Inquéritos e Questionários
14.
Korean J Lab Med ; 27(2): 151-5, 2007 Apr.
Artigo em Coreano | MEDLINE | ID: mdl-18094568

RESUMO

BACKGROUND: Standardization of medical terminology is essential for data transmission between health-care institutions or clinical laboratories and for maximizing the benefits of information technology. Purpose of our study was to standardize the medical terms used in the clinical laboratory, such as test names, units, terms used in result descriptions, etc. During the first year of the study, we developed a standard database of concept names for laboratory terms, which covered the terms used in government health care centers, their branch offices, and primary health care units. METHODS: Laboratory terms were collected from the electronic data interchange (EDI) codes from National Health Insurance Corporation (NHIC), Logical Observation Identifier Names and Codes (LOINC) database, community health centers and their branch offices, and clinical laboratories of representative university medical centers. For standard expression, we referred to the English-Korean/ Korean-English medical dictionary of Korean Medical Association and the rules for foreign language translation. Programs for mapping between LOINC DB and EDI code and for translating English to Korean were developed. RESULTS: A Korean standard laboratory terminology database containing six axial concept names such as components, property, time aspect, system (specimen), scale type, and method type was established for 7,508 test observations. Short names and a mapping table for EDI codes and Unified Medical Language System (UMLS) were added. Synonym tables for concept names, words used in the database, and six axial terms were prepared to make it easier to find the standard terminology with common terms used in the field of laboratory medicine. CONCLUSIONS: Here we report for the first time a Korean standard laboratory terminology database for test names, result description terms, result units covering most laboratory tests in primary healthcare centers.


Assuntos
Técnicas de Laboratório Clínico/classificação , Logical Observation Identifiers Names and Codes , Unified Medical Language System , Técnicas de Laboratório Clínico/normas , Bases de Dados Factuais , Coreia (Geográfico) , Idioma , Terminologia como Assunto
16.
Dig Dis Sci ; 52(9): 2403-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17429737

RESUMO

The levels of HBV replication in the nonreplicative phase are not clear. We conducted this study to evaluate the levels of viral replication during the nonreplicative phase in chronic HBV-infected Korean patients using real-time PCR. A total of 125 patients were classified into three groups: inactive HBsAg carriers, inactive liver cirrhosis patients, and resolved chronic HBV-infected patients with loss of HBsAg. The real-time PCR detected HBV DNA in 112 cases (89.6%). The mean levels of HBV DNA were 3.84, 4.10, and 3.31 log copies/ml in the three groups, respectively (P <0.01). Ninety-five percent of inactive HBsAg carriers showed levels of HBV DNA lower than 6 x 10(4) copies/ml. In conclusion, we showed different levels of HBV DNA exactly in three groups during nonreplicative phases. We suggest that the cutoff level of HBV DNA in inactive HBsAg carriers should be readjusted to a lower level in future studies.


Assuntos
DNA Viral/análise , Vírus da Hepatite B , Hepatite B Crônica , Replicação Viral , Adulto , Feminino , Seguimentos , Antígenos de Superfície da Hepatite B/imunologia , Vírus da Hepatite B/genética , Vírus da Hepatite B/imunologia , Vírus da Hepatite B/fisiologia , Hepatite B Crônica/epidemiologia , Hepatite B Crônica/patologia , Hepatite B Crônica/virologia , Humanos , Incidência , Coreia (Geográfico)/epidemiologia , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase/métodos , Prognóstico , Índice de Gravidade de Doença
17.
J Med Microbiol ; 56(Pt 2): 229-235, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17244805

RESUMO

The mechanisms of resistance to macrolides in 51 erythromycin-resistant clinical isolates of Streptococcus pyogenes collected from 1997 through 2003 in Seoul, Korea were evaluated. They were characterized by their antimicrobial susceptibility, phenotype (using triple-disc and induction tests), resistance genotype, emm genotyping (M typing) and phylogenetic analysis. Erythromycin resistance was observed in 23% of isolates. Inducible phenotype was the most common (iMLS, 51%, 26 strains), followed by the constitutive phenotype (cMLS, 31%, 16 strains) and the M phenotype (18%, 9 strains). Eight of twenty-six iMLS isolates exhibited the iMLS-C phenotype. The remaining 18 isolates gave small inhibition zones (<12 mm) around all three discs, and mild blunting of the spiramycin and clindamycin zones of inhibition proximal to the erythromycin disc. They showed remarkable inducibility in erythromycin and clindamycin resistance. The MIC90 of erythromycin and clindamycin rose from 8 to >128 microg ml-1 and from 0.5 to >128 microg ml-1, respectively. Their resistance characteristics did not fit into any known iMLS subtype reported so far in the literature. So, it was named as an iMLS-D, new subtype. All of these iMLS-D strains harboured the erm(B) gene, demonstrated the emm12 genotype, except one, and formed a tight cluster in a phylogenetic tree, with 89.2 to 100% sequence homology, suggesting that they are closely related. Nine of sixteen cMLS strains had the emm28 genotype, which had been reported to be associated with multiple drug resistance.


Assuntos
Antibacterianos/farmacologia , Farmacorresistência Bacteriana , Macrolídeos/farmacologia , Infecções Estreptocócicas/microbiologia , Streptococcus pyogenes/classificação , Streptococcus pyogenes/efeitos dos fármacos , Adolescente , Adulto , Antígenos de Bactérias/análise , Antígenos de Bactérias/genética , Proteínas da Membrana Bacteriana Externa/análise , Proteínas da Membrana Bacteriana Externa/genética , Proteínas de Transporte/análise , Proteínas de Transporte/genética , Criança , Pré-Escolar , DNA Bacteriano/genética , Genótipo , Humanos , Lactente , Coreia (Geográfico) , Testes de Sensibilidade Microbiana , Fenótipo , Filogenia , Análise de Sequência de DNA , Sorotipagem , Streptococcus pyogenes/genética , Streptococcus pyogenes/fisiologia
18.
Anal Chem ; 78(21): 7392-6, 2006 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-17073404

RESUMO

Protein chips are a powerful emerging technology with extensive biomedical applications. However, the development of optimal, economical surface materials capable of maintaining the activity of embedded proteins is a challenge. Here, we introduce a new optimized, low-cost, sol-gel biomaterial for use in protein chips with femtogram-level sensitivity. A novel protein chip material with significantly improved physical properties and sensitivity was produced using unique screening and selection methods. Using this platform, the sensitive, specific detection of the interactions between an HIV antigen and its antibody and between a cyclin-kinase protein pair was observed. This study is the first to demonstrate the detection of protein-protein interactions on sol-gel microarrays and describes an important improvement in the physical properties of sol-gel-derived protein chip materials for biomedical research.


Assuntos
Proteínas/química , Anticorpos/química , Géis , Sensibilidade e Especificidade
19.
Circ J ; 70(4): 414-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16565557

RESUMO

BACKGROUND: Plasma adiponectin is decreased in patients with coronary artery diseases, especially in patients with acute coronary syndrome (ACS). However, the correlation between plasma adiponectin and variant angina pectoris (VAP) has not been verified. Plasma adiponectin concentrations between VAP and other coronary artery diseases was compared in the present study. The association between plasma adiponectin concentration and VAP was also investigated. METHODS AND RESULTS: Plasma adiponectin concentrations in the VAP group (n=101) were compared with those of the ACS group (n=117), the stable angina pectoris group (n=108), and the normal coronary group (n=81). Plasma adiponectin concentrations in VAP and ACS were significantly lower than that of the normal coronary group (6.6+/-5.4 vs 5.2+/-4.0 vs 9.0 +/-6.2 microg/ml, p<0.001, respectively). Multivariate analysis indicated that plasma adiponectin (odds ratio (OR) 0.735, 95% confidence interval (CI) 0.621-0.855, p=0.011), smoking (OR 2.012, 95% CI 1.210-3.880, p=0.020), and age (OR 0.976, 95% CI 0.957-0.997, p=0.022) correlated independently with the development of VAP. CONCLUSIONS: Our results suggest that a decrease in plasma adiponectin concentration might be associated with the development of VAP.


Assuntos
Adiponectina/sangue , Angina Pectoris Variante/sangue , Adulto , Idoso , Intervalos de Confiança , Angiografia Coronária , Doença da Artéria Coronariana/sangue , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Fatores de Risco
20.
J Virol Methods ; 133(1): 20-6, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16313975

RESUMO

Three fourth-generation antigen/antibody combination assays (Elecsys, AxSYM, Architect HIV) and two third-generation (AxSYM, Centaur) HIV antibody immunoassays were evaluated. The evaluation panel of 479 samples included: nine tissue culture derived HIV-1 strains at four different p24 antigen concentrations (n=36), a p24 antigen sensitivity panel (n=10), 149 HIV-1 or HIV-2 confirmed antibody positive samples, ten anti-HIV-1 positive low titer samples, three seroconversion panels (n=21), and 253 HIV negative samples. The Architect had the best sensitivity for detection of HIV-1 antigen across eight HIV-1 subtypes, followed by the AxSYM while the Elecsys could not detect the highest antigen concentration evaluated (25 pg/mL) for eight of nine virus isolates. All assays showed 100% sensitivity for detection of HIV-1, group M, group O, and HIV-2 antibody positive samples. The Architect Ag/Ab Combo assay detected the first positive bleed of the three seroconversion panels and detected infection 4-26 days earlier than the third generation assays. Based on evaluation of 253 negative samples, assay specificity varied from 98.0% to 99.6%. The Architect HIV Ag/Ab Combo exhibited the best performance for specificity and detection of p24 antigen leading to closure of seroconversion window and demonstrating its utility for early diagnosis of HIV infection.


Assuntos
Anticorpos Anti-HIV/sangue , Antígenos HIV/sangue , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , Soropositividade para HIV/diagnóstico , Imunoensaio/métodos , Complexo Antígeno-Anticorpo , Western Blotting , Estudos de Avaliação como Assunto , Reações Falso-Positivas , Infecções por HIV/virologia , Soropositividade para HIV/virologia , HIV-1/classificação , HIV-1/imunologia , HIV-1/isolamento & purificação , HIV-2/classificação , HIV-2/imunologia , HIV-2/isolamento & purificação , Humanos , Técnicas de Amplificação de Ácido Nucleico , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...