1.
J Clin Lab Anal ; : e25093, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169634

RESUMO

BACKGROUND: Neonatal jaundice (NNJ) affects a significant proportion of newborns globally, with an increased burden in low-resource settings. Effective health risk management of NNJ is hindered, particularly in resource-constrained environments, where early detection and treatment are challenging. The careSTART S1 Total Bilirubin Strip, a point-of-care testing (POCT) device based on a diazo-method, offers a potential solution by enabling onsite bilirubin measurement, thus, addressing the gap in early NNJ detection and management. METHODS: The current study evaluated the analytical performance of the careSTART S1 Total Bilirubin Strip for precision, linearity, method comparison, and lot-to-lot consistency following CLSI guidelines. For method comparison, 105 residual EDTA whole blood samples were analyzed with the careSTART S1 Total Bilirubin Strip and compared with reference measurements from the Roche Cobas c702 analyzer. Additionally, statistical analyses, including Passing-Bablok regression and Bland-Altman plots, were performed. RESULTS: The careSTART S1 Total Bilirubin Strip showed allowable (<10%) within-laboratory imprecision of 2.5%-3.6% across all levels and demonstrated linearity over the range of 4.16-439.3 µmol/L. Method comparison revealed a constant negative bias with a mean bias -4.19 µmol/L. However, the 95% confidence interval (-7.10 to -1.28 µmol/L) of the bias is covered by the prespecified allowable bias of 8.3%, at medical decision point. Lot-to-lot variation ranged from 0.14%-6.49%, and was within the acceptable critical difference of 8.3%. CONCLUSION: The careSTART S1 Total Bilirubin Strip provided accurate and reliable bilirubin measurements that could contribute to neonatal care in settings lacking central laboratory facilities.

2.
Medicine (Baltimore) ; 103(21): e38267, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787980

RESUMO

This study aimed to assess and compare the accuracy of point-of-care CareSTART™ S1 Total Bilirubin test with a central laboratory total bilirubin assay using neonatal samples. This study was conducted using 152 paired measurements obtained from 122 neonates admitted to the neonatal intensive care unit. Total serum bilirubin (TSB) levels assayed with the central laboratory assay, laboratory bilirubinomter, trancutaneous bliribubin (TcB) instrument and CareSTART were compared using Bland-Altman analysis. The mean difference between the CareSTART and TSB values was -1.43 mg/dL and the 95% limit of agreement (LoA) was -4.25 to 1.39 mg/dL. CareSTART tended to underestimate total bilirubin concentrations compared with TcB, however, the LoA was narrower due to the smaller SD of mean difference for CareSTART. The CareSTART Total Bilirubin test provides an accurate alternative to TcB for total serum bilirubin measurement. Given its low-cost, ease-of-use, and portability, the use of CareSTART is expected to provide point-of-care measurements, especially in low-resource settings.


Assuntos
Bilirrubina , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Bilirrubina/sangue , Recém-Nascido , Feminino , Masculino , Unidades de Terapia Intensiva Neonatal , Testes Imediatos , Hiperbilirrubinemia Neonatal/sangue , Hiperbilirrubinemia Neonatal/diagnóstico , Triagem Neonatal/métodos , Reprodutibilidade dos Testes
3.
Expert Rev Hematol ; 15(2): 175-181, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35119350

RESUMO

OBJECTIVES: We examined the frequencies and sizes of glycosylphosphatidylinositol (GPI)-deficient cells as per the International Clinical Cytometry Society/European Society for Clinical Cell Analysis (ICCS/ESCCA) consensus guidelines for the high-sensitivity detection of GPI-deficient cells. METHODS: In 2018, the ICCS/ESCCA guidelines for the high-sensitivity detection of GPI-deficient cells were published. We evaluated frequencies and sizes of GPI-deficient red blood cells (RBCs), neutrophils, and monocytes as determined using the ICCS/ESCCA guidelines and Clinical and Laboratory Standards Institute (CLSI) guidelines in patients with a hematologic malignancy, aplastic anemia, or cytopenia. RESULTS: A total of 106 (38.7%) patients exhibited GPI deficiency in at least one blood cell lineage. GPI-deficient cells of one or more lineages were found in 62.7% of patients with a hematologic malignancy, 51.1% of patients with aplastic anemia, and 23.4% of patients with cytopenia. GPI-deficient monocytes were most frequently detected in all three groups. By population size, GPI-deficient clones (>1%) in monocytes were mostly detected in patients with a hematologic malignancy or aplastic anemia. Rare cells with GPI deficiency (<0.1%) in monocytes were most common among patients with cytopenia. CONCLUSION: High-sensitive flow cytometry analysis including monocytes may be necessary for patients with a hematologic disorder.


Assuntos
Anemia Aplástica , Neoplasias Hematológicas , Hemoglobinúria Paroxística , Trombocitopenia , Anemia Aplástica/diagnóstico , Anemia Aplástica/genética , Citometria de Fluxo , Glicosilfosfatidilinositóis/deficiência , Hemoglobinúria Paroxística/diagnóstico , Hemoglobinúria Paroxística/genética , Humanos , Convulsões
4.
J Clin Lab Anal ; 33(5): e22869, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30860622

RESUMO

BACKGROUND: Apixaban and rivaroxaban are approved for the prevention and treatment of deep vein thrombosis (DVT), pulmonary embolism (PE), and embolic stroke in atrial fibrillation (AF) patients. The aim of this study was to find appropriate methods of monitoring the anticoagulant effects of are direct oral anticoagulants (DOACs) and establish on-therapy ranges using conventional tests. METHODS: A total of 184 samples were collected from 91 patients receiving DOACs. Concentrations of apixaban and rivaroxaban in plasma were accessed by an anti-factor Xa chromogenic assay. PT, APTT, antithrombin, D-dimer, dRVVT screen/confirm, FDP, and fibrinogen levels were measured. On-therapy ranges were calculated by substituting previously reported trough plasma concentrations of DOACs. RESULTS: Anti-factor Xa chromogenic assay-based DOACs levels were 26.0-279.5 (115.9 ± 56.5) ng/mL for apixaban at 2.5 mg BID, 19.9-565.1 (205.3 ± 162.4) ng/mL for apixaban at 5 mg BID, 2.3-395.3 (205.3 ± 162.4) ng/mL for rivaroxaban at 15 mg OD, 3.6-494.8 (119.6 ± 95.1) ng/mL for rivaroxaban at 20 mg OD, and 9.6-431.4 (140.8 ± 113.6) ng/mL for rivaroxaban at 15 mg BID. PT (%), antithrombin, and dRVVT confirm tests showed good correlation with plasma apixaban levels. Plasma rivaroxaban concentrations were correlated well with PT (sec), PT (%),and dRVVT confirm results. On-therapy ranges established for dRVVT confirm test by linear regression were as follows: 1.32-1.52 for apixaban 2.5 mg BID, 1.12-1.75 for apixaban 5 mg BID, 1.11-1.78 for rivaroxaban 15 mg OD, 1.09-1.64 for rivaroxaban 20 mg OD, and 1.22-1.81 for rivaroxaban 20 mg BID. CONCLUSIONS: Apixaban concentrations were well correlated with PT (%), antithrombin, and dRVVT confirm test. Rivaroxaban concentrations showed good correlation with PT (sec), PT (%), and dRVVT confirm test.


Assuntos
Testes de Coagulação Sanguínea/métodos , Inibidores do Fator Xa/sangue , Pirazóis/sangue , Piridonas/sangue , Rivaroxabana/sangue , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Laboratório Clínico , Inibidores do Fator Xa/uso terapêutico , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Fibrinogênio/análise , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Protrombina , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Rivaroxabana/uso terapêutico , Venenos de Víboras
5.
J Clin Lab Anal ; 33(4): e22841, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30724410

RESUMO

BACKGROUND: Bone marrow (BM) study plays an important role as initial investigation specimen of lymphoma as well as staging lymphoma. This study aimed to investigate the utility of BM studies for classification of lymphoma and evaluate features of BM involvement by lymphoma over a period of 11 years. METHODS: A total of 1162 cases of BM studies for lymphoma evaluation were reviewed for the incidence of lymphoma subtypes, the percentage of marrow involvement, the pattern of involvement and discordance with histopathologic diagnoses of lymph nodes and other tissues. RESULTS: A total of 255 of 1162 cases underwent BM study without pathologic information, and 108 cases show lymphoma involvement. Lymph node biopsy underwent in 66 cases, and 10 cases show discordant result between BM and lymph node biopsy. Seven discordant cases were due to insufficient further studies. Lymphoma was diagnosed only by BM study in 38 cases. Abnormal lymphocytes were found in BM aspiration in 34 cases. Also, abnormal clonal lymphocytes were detected by flow cytometry in 26 cases. Four cases showed disease-related chromosomal abnormalities. FISH analysis detected abnormal findings in two cases, however, discordant with other additional studies. CONCLUSIONS: Discrepancies between the BM study and lymph node biopsy were due to insufficient further study and discordance of immunohistochemical stain result. BM study can be utilized as initial diagnosis of lymphoma by the combination of morphological feature, involvement pattern, and additional tests such as flow cytometry, chromosomal analysis, and FISH analysis. Thus, BM study with further analysis is an essential choice when lymph node biopsies are unavailable.


Assuntos
Medula Óssea/patologia , Linfoma/patologia , Biópsia de Linfonodo Sentinela , Humanos
6.
J Obstet Gynaecol Res ; 45(1): 69-77, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30230126

RESUMO

AIM: Group B streptococcus (GBS) is a leading cause of life-threatening bacterial infections among newborns, and neonates born to heavily colonized women may be subject to vertical transmission. We sought to determine an appropriate detection method for genital GBS in pregnant women by comparing culture-based methods and real-time polymerase chain reaction (PCR). In addition, we performed molecular serotyping and multilocus sequence typing (MLST) on isolates. METHODS: A total of 150 pregnant women were enrolled and underwent vaginal-rectal swabbing at 16-40 weeks of gestation. GBS was identified by conventional culture and real-time PCR with or without enrichment. Molecular serotyping and MLST were performed on isolates. RESULTS: Overall genital GBS positive rate among the 150 study subjects was 17.3%. Direct culture identified 18 (12.0%) positive specimens, enrichment culture 22 (14.6%), direct PCR 24 (16.0%) and enrichment PCR 25 (16.6%). The sensitivity and specificity by direct and enrichment PCR were as follows: for direct PCR, 90.9% and 96.9%, respectively; and for enrichment PCR, 95.5% and 96.9%, respectively. Resistance rates to clindamycin and erythromycin were 33.3% and 19.1%, respectively. Serotype III-1 was the most common (26.3%), followed by serotype Ib (21.1%), III-3 (15.8%), V (15.8%), II (10.5%), IV (5.3%) and VI (5.3%). Most common sequence types (ST) were ST-1, ST-19 and ST-862 (15.8%), followed by ST-2 and ST-654 (10.5%). CONCLUSION: Direct real-time PCR using vaginal-rectal specimen could be used for detecting GBS in emergent conditions. Molecular serotypes III, Ib and V were most common. MLST analysis frequently presented ST-1, ST-19 and ST-862.


Assuntos
Genoma Bacteriano , Genômica/métodos , Complicações Infecciosas na Gravidez/microbiologia , Sorogrupo , Infecções Estreptocócicas/microbiologia , Streptococcus/genética , Adulto , Feminino , Humanos , Tipagem de Sequências Multilocus/métodos , Gravidez , Complicações Infecciosas na Gravidez/epidemiologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , República da Coreia/epidemiologia , Sorotipagem/métodos , Infecções Estreptocócicas/epidemiologia , Streptococcus/classificação