Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Infect Dis ; 30: 27-32, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25461656

RESUMO

BACKGROUND AND OBJECTIVES: The transmembrane glycoprotein TREM-1 triggers an inflammatory response. Its soluble fraction (sTREM-1) has been shown to have diagnostic accuracy for late-onset neonatal sepsis (LONS). Until now, the potential of sTREM-1 to predict septic shock and/or death in septic neonates has not been explored. This study obtained estimates of the incidence and prevalence of septic shock and/or death in septic neonates for future sample size calculations for confirmatory studies and evaluated the feasibility of using sTREM-1 as a predictor of septic shock and/or death in neonates with LONS criteria. STUDY DESIGN: A pilot study with a cross-sectional design was performed from May 1(st) to October 31(st), 2012. The participants were hospitalized neonates who, after three days of life, were diagnosed as having LONS. Plasma sTREM-1 was quantified by ELISA. The main outcome measurement was the development of septic shock and/or death. RESULTS: Of 71 eligible subjects, nine (12.7%) progressed to septic shock and/or death. In the LONS-Non-Shock group, the sTREM-1 median and interquartile range (IQR) plasma value were 10 (10 to 70) pg/mL. In the LONS & Shock/Death group, the values were 567 (260 to 649) pg/mL. These values were significantly different (Mann-Whitney's U test, p=0.001). A ROC curve for a proposed sTREM-1 cut-off value of 300 pg/mL exhibited an area under the curve of 0.884 (95% CI=0.73 to 1.0; p<0.0001), with a sensitivity of 0.78 (95% CI=0.46 to 0.94) and specificity of 0.97 (95% CI=0.92 to 0.99); PPV would be 0.78 (95% CI=0.46 to 0.94) and NPV 0.97 (95% CI=0.92 to 0.99). CONCLUSIONS: In neonates with LONS, sTREM-1 has the potential to provide an excellent predictive value for septic shock/death. Larger sample sizes are needed to identify the optimal cut-off value of plasma sTREM-1 for this diagnosis and to provide diagnostic accuracy measures.


Assuntos
Glicoproteínas de Membrana/sangue , Receptores Imunológicos/sangue , Sepse/mortalidade , Choque Séptico/diagnóstico , Estudos Transversais , Progressão da Doença , Feminino , Humanos , Recém-Nascido , Doenças do Recém-Nascido/sangue , Doenças do Recém-Nascido/epidemiologia , Doenças do Recém-Nascido/mortalidade , Masculino , Projetos Piloto , Curva ROC , Sensibilidade e Especificidade , Sepse/sangue , Sepse/diagnóstico , Sepse/epidemiologia , Choque Séptico/epidemiologia , Receptor Gatilho 1 Expresso em Células Mieloides
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...