Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 77(3): 234-242, 2024 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38476000

RESUMO

INTRODUCTION AND OBJECTIVES: The optimal timing of coronary angiography in patients admitted with non-ST-segment elevation acute coronary syndrome (NSTEACS) as well as the need for pretreatment are controversial. The main objective of the IMPACT-TIMING-GO registry was to assess the proportion of patients undergoing an early invasive strategy (0-24hours) without dual antiplatelet therapy (no pretreatment strategy) in Spain. METHODS: This observational, prospective, and multicenter study included consecutive patients with NSTEACS who underwent coronary angiography that identified a culprit lesion. RESULTS: Between April and May 2022, we included 1021 patients diagnosed with NSTEACS, with a mean age of 67±12 years (23.6% women). A total of 87% of the patients were deemed at high risk (elevated troponin; electrocardiogram changes; GRACE score>140) but only 37.8% underwent an early invasive strategy, and 30.3% did not receive pretreatment. Overall, 13.6% of the patients underwent an early invasive strategy without pretreatment, while the most frequent strategy was a deferred angiography under antiplatelet pretreatment (46%). During admission, 9 patients (0.9%) died, while major bleeding occurred in 34 (3.3%). CONCLUSIONS: In Spain, only 13.6% of patients with NSTEACS undergoing coronary angiography received an early invasive strategy without pretreatment. The incidence of cardiovascular and severe bleeding events during admission was low.


Assuntos
Síndrome Coronariana Aguda , Angiografia Coronária , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda/terapia , Angiografia Coronária/efeitos adversos , Estudos Prospectivos , Espanha/epidemiologia , Inibidores da Agregação Plaquetária/efeitos adversos , Fatores de Tempo
2.
Angiology ; 72(10): 979-985, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33966474

RESUMO

BACKGROUND: Both stent length and stent overlap are associated with worse outcomes in the percutaneous treatment of diffuse coronary artery disease (dCAD). However, evidence comparing these issues is scarce. We aimed to compare the results between the use of single very long stent (VLS) and ≥2 overlapping stents (OS) in the treatment of dCAD. METHODS: Seven hundred twenty-four consecutive lesions were included: 275 treated with a single VLS (≥40 mm) and 449 with ≥2 OS. Procedural characteristics were assessed, and survival analysis was performed to compare the incidence of major adverse cardiovascular events (MACE; composite of cardiovascular death, nonfatal myocardial infarction, target lesion revascularization [TLR], or stent thrombosis) during a median follow-up of 31 months. RESULTS: Procedures with VLS required less contrast volume (268 ± 122 vs 302 ± 113 cm3; P < .01), fluoroscopy time (16 ± 8 vs 21 ± 16 minutes; P < .01), and procedure duration (37 ± 18 vs 47 ± 27 minutes; P < .01) than the OS procedures. The VLS group showed lower incidence of MACE (4.4% vs 10.7%; P < .01), driven mainly by lower TLR rate (1.1% vs 4.7%; P < .01). The use of OS was an independent predictor of MACE. CONCLUSIONS: In this study, the use of VLS for the treatment of dCAD was associated with better outcomes compared to OS.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Stents , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Fatores de Tempo , Resultado do Tratamento
3.
Angiology ; 72(4): 364-370, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33334115

RESUMO

Drug-eluting balloons currently constitute a therapeutic tool used in percutaneous coronary interventions (PCI). Long-term results remain unknown. We evaluated the prognosis of PCI using a second generation paclitaxel-eluting balloon (PEB) in real-world patients. We included all PCI with PEB in de novo or in-stent restenosis coronary lesions performed in our unit from March 2009 to March 2019. We assessed the composite of major adverse cardiovascular events (MACE) rate after a median follow-up of 42 months. Consecutive patients (n = 320) with 386 lesions were included; 46.9% presented with stable angina and 53.1% acute coronary syndromes; 52.6% of the lesions were in-stent restenosis and 47.3% de novo lesions with a mean diameter of 2.4 ± 0.5 mm. A bare metal stent was implanted in 6.7% and a drug-eluting stent in 8.5% of patients. The MACE rate was 8%: 10 (2.6%) cardiovascular deaths, 13 (3.4%) myocardial infarctions, and 16 (4.1%) target lesion revascularization. The all-cause death rate was 5.2%. No cases of thrombosis were recorded. In conclusion, PEB was a safe and effective tool to treat in-stent restenosis and de novo coronary lesions, especially small vessel disease, during long-term follow-up.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/uso terapêutico , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Paclitaxel/uso terapêutico , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Cardiovasc Revasc Med ; 21(11): 1355-1359, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32354584

RESUMO

BACKGROUND: The clinical impact of percutaneous coronary intervention (PCI) and implantation of overlapping stents (OS) using platforms with the same versus different pharmacological characteristics is unknown. Our objective was to compare the outcomes of PCI with OS according to their pharmacological characteristics. METHODS: In this observational single-center registry, we included all PCI performed from April 2014 to December 2018 in which overlapping drug-eluting stents were implanted. Two groups were created according to whether the stents release the same drug [homogeneous: (HO)] or different [heterogeneous: (HE)]. The primary endpoint was the need for target lesion revascularization (TLR). Clinical assessment was performed after the procedure, bianually and at the end of follow-up (June 2019). RESULTS: 381 lesions with OS (HO: 209; HE: 172) were included (75.1% male, 66.7 ±â€¯11.6 years). Clinical presentation was stable coronary artery disease in 49.9%. Syntax score was 23.7 ±â€¯13.3. The number of OS implanted was 2.2 ±â€¯0.5 and the total stent length was 59.5 ±â€¯20.1 mm (HE: 61.5 ±â€¯21.6 vs. HO: 57.8 ±â€¯18.8 mm; p < 0.01). After a median follow-up of 21 months, the HE group showed a lower TLR rate than the HO group (HE:2.3% vs HO:7.2%; p = 0.03). The rates of cardiac death (p = 0.44), myocardial infarction (p = 0.36) and stent thrombosis (p = 0.85) were similar between groups. In the multivariate analysis, the OS with homogeneous-drug devices was an independent predictor of a higher rate of TLR. CONCLUSIONS: PCI using OS with homogeneous pharmacological characteristics was associated with a higher rate of TLR in comparison with the implantation of OS with heterogeneous pharmacological characteristics.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Idoso , Stents Farmacológicos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Resultado do Tratamento
5.
J Invasive Cardiol ; 32(3): E73, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32123145

RESUMO

The recognition of woven coronary artery anomaly is difficult because of its rare nature. Optical coherence tomography imaging is challenging due to the tortuosity of the channels; however, it is crucial not only for the differential diagnosis but also to guide the treatment approach.


Assuntos
Doença da Artéria Coronariana , Anomalias dos Vasos Coronários , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia de Coerência Óptica
6.
J Invasive Cardiol ; 31(4): E62-E63, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30927536
9.
Cardiovasc Revasc Med ; 20(8): 681-686, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30243961

RESUMO

BACKGROUND: The stent length as well as the stent overlap for the percutaneous treatment of diffuse coronary disease have been considered predictors of adverse events. However, there are no comparative data on the use of very long stents or overlapping stents in this scenario. OBJECTIVE: To compare the clinical results of very long stents (≥40 mm) or overlapping stents in real clinical practice. METHODS: We included 643 lesions in 628 consecutive patients treated with a single very long stent (≥40 mm) (251 lesions) or ≥2 overlapped stents (392 lesions). We analyzed the procedural characteristics and the presentation of the combined endpoint [cardiovascular death, non-fatal myocardial infarction, need for target lesion revascularization or stent thrombosis] after a follow-up of 20 months. RESULTS: Total stent length was 54 ±â€¯18 mm and minimum diameter was 2.9 ±â€¯1.2 mm. At the end of follow-up, the rate of adverse events was 8.3% (cardiac death: 4.9%, myocardial infarction: 1.7%, target lesion revascularization: 3.1%, stent thrombosis: 0.7%). There were no significant differences between both groups in the presentation of the combined endpoint. Procedures with overlapping stents had more contrast volume (309 ±â€¯115 vs 273 ±â€¯127 ml; p = 0.002), longer duration (47 ±â€¯22 vs 39 ±â€¯18 min; p < 0.0001), higher fluoroscopy time (20 ±â€¯13 vs 16 ±â€¯9 min; p < 0.0001) and higher number of stents to treat the index lesion (2.2 ±â€¯0.5 vs 1; p < 0.0001). CONCLUSIONS: New designs of very long stents allow not only treating increasingly complex lesions, but also simplifying the procedure and decreasing the number of stents with very favorable results similar to those obtained with stent overlap.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Stents , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 19(5 Pt A): 493-497, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29169982

RESUMO

AIMS: To analyse systematic isolated post-dilatation of the side branch as a part of provisional stent technique. METHODS: 1960 angioplasties performed in two centres were prospectively registered, of which 382 were coronary bifurcations with a side branch>2mm. In centre A, isolated post-dilatation of the side branch was performed regardless its impairment after main vessel stenting. In centre B, side branch post-dilatation was performed only if it was severely affected after stent implantation. RESULTS: There was no difference between the two centres in the rate of side branch affection after stent implantation (A: 44.6 vs B: 49.3%, p=0.48) nor in the procedural success rate (A: 98.6% vs B: 96.7%, p=0.45). After one-year follow-up, a reduction of cardiovascular events was observed in centre A (A: 4.4% vs B: 10.4%, p=0.043) with a trend towards lower cardiac mortality (A: 2.2% vs B: 6.5%, p=0.093) and stent thrombosis (A: 0% vs B: 2.6%, p=0.077). There were no differences in the rate of myocardial infarction related to the treated artery (A: 1.4% vs B: 3.9%, p=0.29), or target lesion revascularization (A: 1.4% vs. B: 3.2%, p=0.45). CONCLUSIONS: Systematic isolated post-dilatation of the side branch in the provisional stent technique was associated with a high angiographic success rate, and a low rate of cardiovascular events during follow-up. Although the study design does not allow definitive conclusions, this strategy could be considered a valid option in some cases or even as part of the provisional stent technique.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/cirurgia , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Intervencionista , Sistema de Registros , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
11.
J Invasive Cardiol ; 29(7): E81-E82, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28667810

RESUMO

A 53-year-old man underwent percutaneous coronary intervention of a chronic total occlusion of the circumflex artery. A mini-crush stent technique with two drug-eluting stents was performed. To the best of our knowledge, this is the first case of coronary artery aneurysm affecting a bifurcated chronic total occlusion treated with a two-stent technique.


Assuntos
Aneurisma Coronário/etiologia , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Doença Crônica , Aneurisma Coronário/diagnóstico , Angiografia Coronária , Oclusão Coronária/diagnóstico , Vasos Coronários/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Tomografia de Coerência Óptica
13.
Rev Port Cardiol ; 36(2): 141.e1-141.e3, 2017 Feb.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28159428

RESUMO

A single coronary artery is one of the most rarely seen coronary artery anomalies. In addition, the specific subtype (Lipton RII-A) that our patient presented is one of the least common, and its clinical presentation as myocardial infarction and cardiac arrest has not been described in the literature. The case shows that although it is essential to exclude a malignant interarterial course of the vessel, cardiac arrest is a possible clinical presentation produced by myocardial ischemia in the context of acute myocardial infarction and should be managed according to clinical practice guidelines.


Assuntos
Anomalias dos Vasos Coronários/complicações , Infarto do Miocárdio/etiologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
14.
Cardiovasc Revasc Med ; 18(6S1): 38-40, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28089777

RESUMO

Nickel is the most frequent allergen in patients with allergic contact dermatitis and nickel allergy has been associated with recurrent in-stent restenosis. However, it is often misdiagnosed because of a low suspicion threshold. It should be discarded in patients with recurrent in-stent restenosis, especially if their medical history reveals prior contact dermatitis. It is also noteworthy and rarely specified that even newer generation stents that use novel metal alloys also contain low amounts of nickel. To avoid the implantation of new stents containing this metal, when percutaneous coronary intervention is indicated, drug eluting balloons or bioresorbable vascular scaffolds associated with small doses of steroids could provide good alternatives of treatment. To the best of our knowledge, this is the first description of this therapeutic alternative in such an exceedingly rare clinical scenario.


Assuntos
Implantes Absorvíveis , Reestenose Coronária/terapia , Stents Farmacológicos , Hipersensibilidade/complicações , Níquel/imunologia , Implantes Absorvíveis/efeitos adversos , Angiografia Coronária/métodos , Reestenose Coronária/complicações , Reestenose Coronária/diagnóstico , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Hipersensibilidade/imunologia , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento
16.
Case Rep Cardiol ; 2016: 7387946, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27642527

RESUMO

Endoscopic ultrasound is a diagnostic and therapeutic technique used in specialized centers for patients that have undergone digestive procedures. This technique enables highly precise real-time imaging of the digestive tract wall and surrounding organs. Endoscopic ultrasound is also useful in patients with cardiovascular diseases such as atrial fibrillation. In patients with contraindication for transesophageal echocardiography due to high risk of esophageal bleeding or complications that may require immediate intervention, endoscopic ultrasound may be a safer option for visualizing atrial chambers to rule out the presence of left atrial appendage thrombi before cardioversion.

17.
Cardiovasc Revasc Med ; 17(5): 328-32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27085219

RESUMO

BACKGROUND AND PURPOSE: A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit. METHODS: We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software "last fluoroscopy hold". RESULTS: There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p<0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p=0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p=0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6min; p=0.14), or the fluoroscopy time (13.3 vs 13.2min; p=0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p<0.0001) or aortography (15.4% vs 4.4%; p<0.0001), the cine runs (21.8 vs 6.9; p<0.0001) and the dose-area product (165 vs 71 Gyxcm(2); p<0.0001). CONCLUSIONS: With the implementation of a simple radiation reduction protocol, a 57% reduction of dose-area product was observed without a reduction in the quality or the complexity of procedures.


Assuntos
Cateterismo Cardíaco , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Salas Cirúrgicas/organização & administração , Intervenção Coronária Percutânea , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Aortografia , Cateterismo Cardíaco/efeitos adversos , Cineangiografia , Angiografia Coronária , Feminino , Fluoroscopia , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Saúde Ocupacional , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Ventriculografia com Radionuclídeos , Software , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...