Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent ; 145: 105024, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38670332

RESUMO

OBJECTIVE: Rapid maxillary expansion is a common orthodontic procedure to correct maxillary constriction. Assessing the midpalatal suture (MPS) expansion plays a crucial role in treatment planning to determine its effectiveness. The objectives of this preliminary investigation are to demonstrate a proof of concept that the palatal bone underlying the rugae can be clearly imaged by ultrasound (US) and the reconstructed axial view of the US image accurately maps the MPS patency. METHODS: An ex-vivo US scanning was conducted on the upper jawbones of two piglet's carcasses before and after the creation of bone defects, which simulated the suture opening. The planar images were processed to enhance bone intensity distribution before being orderly stacked to fuse into a volume. Graph-cut segmentation was applied to delineate the palatal bone to generate a bone volume. The accuracy of the reconstructed bone volume and the suture opening was validated by the micro-computed tomography (µCT) data used as the ground truth and compared with cone beam computed tomography (CBCT) data as the clinical standard. Also included in the comparison is the rugae thickness. Correlation and Bland-Altman plots were used to test the agreement between the two methods: US versus µCT/CBCT. RESULTS: The reconstruction of the US palatal bone volumes was accurate based on surface topography comparison with a mean error of 0.19 mm for pre-defect and 0.15 mm and 0.09 mm for post-defect models of the two samples, respectively when compared with µCT volumes. A strong correlation (R2 ≥ 0.99) in measuring MPS expansion was found between US and µCT/CBCT with MADs of less than 0.05 mm, 0.11 mm and 0.23 mm for US, µCT and CBCT, respectively. CONCLUSIONS: It was possible to axially image the MPS opening and rugae thickness accurately using high-frequency ultrasound. CLINICAL SIGNIFICANCE: This study introduces an ionizing radiation-free, low-cost, and portable technique to accurately image a difficult part of oral cavity anatomy. The advantages of conceivable visualization could promise a successful clinical examination of MPS to support the predictable treatment outcome of maxillary transverse deficiency.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Técnica de Expansão Palatina , Ultrassonografia , Microtomografia por Raio-X , Animais , Suínos , Microtomografia por Raio-X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Técnica de Expansão Palatina/instrumentação , Ultrassonografia/métodos , Palato/diagnóstico por imagem , Palato/anatomia & histologia , Suturas Cranianas/diagnóstico por imagem , Suturas Cranianas/anatomia & histologia , Maxila/diagnóstico por imagem , Palato Duro/diagnóstico por imagem , Palato Duro/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
3.
Ultrasound Med Biol ; 49(9): 1960-1969, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37277305

RESUMO

OBJECTIVE: An approach to estimation of hip displacement on ultrasound (US) images is described. Its accuracy is validated through numerical simulation, an in vitro study with 3-D-printed hip phantoms and pilot in vivo data. METHODS: A diagnostic index, migration percentage (MP), is defined by the ratio of acetabulum-femoral head distance to femoral head width. The acetabulum-femoral head distance could be measured directly on hip US images, while the femoral head width was estimated from the diameter of a best-fit circle. Simulation was performed to evaluate the accuracy of circle fitting with noiseless and noisy data. Surface roughness was also considered. Nine hip phantoms (three different sizes of femur head × three MP values) and 10 US hip images were used in this study. RESULTS: The maximum diameter error was 16.1 ± 8.5% when the roughness and noise were 20% of the original radius and 20% of the wavelet peak, respectively. In the phantom study, the percentage errors of MPs between the 3-D-design US and X-ray US were 0.3%-6.6% and 0.0%-5.7%, respectively. From the pilot clinical trial, the mean absolute difference between the X-ray-US MPs was 3.5 ± 2.8% (1%-9%). CONCLUSION: This study indicates that the US method can be used to evaluate hip displacement in children.


Assuntos
Paralisia Cerebral , Luxação do Quadril , Humanos , Criança , Luxação do Quadril/diagnóstico por imagem , Paralisia Cerebral/complicações , Paralisia Cerebral/diagnóstico por imagem , Cabeça do Fêmur/diagnóstico por imagem , Ultrassonografia , Imagens de Fantasmas
5.
Int J Dent ; 2023: 5494429, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845629

RESUMO

Background: Ultrasonography is a noninvasive, low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess periodontal biomarkers. Objectives: To evaluate the reliability of interlandmark distance measurements on intraoral ultrasound images of the periodontal tissues. Materials and Methods: Sixty-four patients from the graduate periodontics (n = 33) and orthodontics (n = 31) clinics were recruited. A 20 MHz handheld intraoral ultrasound transducer was used to scan maxillary and mandibular incisors, canines, and premolars. Distances between the alveolar bone crest and cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT) were measured by 3 raters. The intercorrelation coefficient (ICC) and mean absolute deviation (MAD) were calculated among and between the raters. Raters also scored images according to quality. Results: The ICC scores for intrarater reliability were 0.940 (0.932-0.947), 0.953 (0.945-0.961), and 0.859 (0.841-0.876) for ABC-CEJ, GT, and ABT, respectively. The intrarater MAD values were 0.023 (±0.019) mm, 0.014 (±0.005) mm, and 0.005 (±0.003) mm, respectively. The ICC scores for interrater reliability were 0.872 (95% CI: 0.836-0.901), 0.958 (95% CI: 0.946-0.968), and 0.836 (95% CI: 0.789-0.873) for ABC-CEJ, GT, and ABT, respectively. The interrater MAD values were 0.063 (±0.029) mm, 0.023 (±0.018) mm, and 0.027 (±0.012) mm, respectively. Conclusions: The present study showed the high reliability of ultrasound in both intrarater and interrater assessments. Results suggest there might be a potential use of intraoral ultrasound to assess periodontium.

6.
Ultrasound Med Biol ; 49(5): 1345-1350, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36813583

RESUMO

OBJECTIVE: Alveolar crestal bone thickness and level provide important diagnostic and prognostic information for orthodontic treatment, periodontal disease management and dental implants. Ionizing radiation-free ultrasound has emerged as a promising clinical tool in imaging oral tissues. However, the ultrasound image is distorted when the wave speed of the tissue of interest is different from the mapping speed of the scanner and, therefore, the subsequent dimension measurements are not accurate. This study was aimed at deriving a correction factor that can be applied to the measurements to correct for discrepancy caused by speed variation. METHODS: The factor is a function of the speed ratio and the acute angle that the segment of interest makes with the beam axis perpendicular to the transducer. The phantom and cadaver experiments were designed to validate the method. DISCUSSION: The comparisons agree well with absolute errors not more than 4.9%. Dimension measurements on ultrasonographs can be properly corrected by applying the correction factor without recourse to the raw signals. CONCLUSION: The correction factor has reduced the measurement discrepancy on the acquired ultrasonographs for the tissue whose speed is different from the scanner's mapping speed.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Humanos , Processo Alveolar/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia , Cadáver
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3173-3176, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891915

RESUMO

Hip displacement is a common orthopedic abnormality in children with cerebral palsy and is assessed on anteroposterior pelvic radiographs during surveillance. Repeated exposure to ionizing radiation is a major concern of cancer risks for children. Ultrasound (US) has been proposed to image the hips. The severity of hip displacement is measured by the Reimers' migration percentage (MP), which is calculated by the ratio of the femoral head distance from the acetabulum to the width of the femoral head. Methods have been published to estimate MP from the US hip images in literature; however, validation for accuracy has not been reported. This study aimed to determine the accuracy of the 2D ultrasound techniques using two 3D printed hip phantoms with known MP values. The MPs estimated from the US images were compared with those measured from the X-ray images. Based on the experimental results, the US measurements had a maximum absolute discrepancy of 2.2% as compared to 9.8% from the X-ray measurements for the MP. The study on phantoms has showed the proposed US approach is promising with better accuracy and without ionizing radiation.Clinical Relevance - If the accuracy is proved to be at least as good as the current X-ray gold standard, the proposed US method will provide a modality of choice to pediatric patients for hip displacement diagnostics and hip surveillance, especially those with cerebral palsy. The method will be free of ionizing radiation and therefore significantly improve the pediatric patient care.


Assuntos
Paralisia Cerebral , Luxação do Quadril , Acetábulo , Paralisia Cerebral/diagnóstico por imagem , Criança , Luxação do Quadril/diagnóstico por imagem , Humanos , Radiografia , Ultrassonografia
8.
ACS Appl Mater Interfaces ; 11(36): 33323-33335, 2019 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-31464413

RESUMO

An ex vivo heart perfusion device preserves the donor heart in a warm beating state during transfer between extraction and implantation surgeries. One of the current challenges includes the use of rigid and noncompliant plastic tubes, which causes injuries to the heart at the junction between the tissue and the tube. The compliant and rapidly strain-stiffening mechanical property that generates a "J-shaped" stress-strain behavior is necessary for producing the Windkessel effect, which ensures continuous flow of blood through the aorta. In this study, we mimic the J-shaped and anisotropic stress-strain behavior of human aorta in synthetic elastomers to replace the problematic noncompliant plastic tube. First, we assess the mechanical properties of human (n = 1) and porcine aorta (n = 14) to quantify the nonlinear and anisotropic behavior under uniaxial tensile stress from five different regions of the aorta. Second, fabric-reinforced elastomer composites were prepared by reinforcing silicone elastomers with embedded fabrics in a trilayer geometry. The knitted structures of the fabric provide strain-stiffening as well as anisotropic mechanical properties of the resulting composite in a deterministic manner. By optimizing the combination between different elastomers and fabrics, the resulting composites matched the J-shaped and anisotropic stress-strain behavior of natural human and porcine aorta. Finally, improved analytical constitutive models based on Gent's and Mooney-Rivlin's constitutive model (to describe the elastomer matrix) combined with Holzapfel-Gasser-Ogden's model (to represent the stiffer fabrics) were developed to describe the J-shaped behavior of the natural aortas and the fabric-reinforced composites. We anticipate that the suggested fabric-reinforced silicone elastomer composite design concept can be used to develop complex soft biomaterials, as well as in emerging engineering fields such as soft robotics and microfluidics, where the Windkessel effect can be useful in regulating the flow of fluids.


Assuntos
Aorta/fisiologia , Elastômeros/farmacologia , Estresse Mecânico , Animais , Anisotropia , Aorta/efeitos dos fármacos , Fenômenos Biomecânicos , Feminino , Humanos , Suínos , Resistência à Tração
9.
Adv Healthc Mater ; 7(22): e1801033, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30338670

RESUMO

Wearable healthcare systems require skin-adhering electrodes that allow maximal comfort for patients as well as an electronics system to enable signal processing and transmittance. Textile-based electronics, known as "e-textiles," is a platform technology that allows comfort for patients. Here, two-layered e-textile patches are designed by controlled permeation of Ag-particle/fluoropolymer composite ink into a porous textile. The permeated ink forms a cladding onto the nanofibers in the textile substrate, which is beneficial for mechanical and electrical properties of the e-textile. The printed e-textile features conductivity of ≈3200 S cm-1 , whereas 1000 cycles of 30% uniaxial stretching causes the resistance to increase only by a factor of ≈5, which is acceptable in many applications. Controlling over the penetration depth enables a two-layer design of the e-textile, where the sensing electrodes and the conducting traces are printed in the opposite sides of the substrate. The formation of vertical interconnected access is remarkably simple as an injection from a syringe. With the custom-developed electronic circuits, a surface electromyography system with wireless data transmission is demonstrated. Furthermore, the dry e-textile patch collects electroencephalography with comparable signal quality to commercial gel electrodes. It is anticipated that the two-layered e-textiles will be effective in healthcare and sports applications.


Assuntos
Eletrônica , Dispositivos Eletrônicos Vestíveis , Encéfalo/fisiologia , Eletrodos , Eletroencefalografia , Humanos , Músculos/fisiologia , Nanocompostos/química
10.
ACS Appl Mater Interfaces ; 9(38): 33100-33106, 2017 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-28836752

RESUMO

In a cold night, a clear window that will become opaque while retaining the indoor heat is highly desirable for both privacy and energy efficiency. A thermally responsive material that controls both the transmittance of solar radiance (predominantly in the visible and near-infrared wavelengths) and blackbody radiation (mainly in the mid-infrared) can realize such windows with minimal energy consumption. Here, we report a smart coating made from polyampholyte hydrogel (PAH) that transforms from a transparency state to opacity to visible radiation and strengthens opacity to mid-infrared when lowering the temperature as a result of phase separation between the water-rich and polymer-rich phases. To match a typical temperature fluctuation during the day, we fine-tune the phase transition temperature between 25 and 55 °C by introducing a small amount of relatively hydrophobic monomers (0.1 to 0.5 wt % to PAH). To further demonstrate an actively controlled, highly flexible, and high-contrast smart window, we build in an array of electric heaters made of printed elastomeric composite. The multipixelated window offers rapid switching, ∼70 s per cycle, whereas the device can withstand high strain (up to 80%) during operations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...