Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(4)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36835785

RESUMO

(1) The use of high-flow nasal cannula (HFNC) combined with frequent respiratory monitoring in patients with acute hypoxic respiratory failure due to COVID-19 has been shown to reduce intubation and mechanical ventilation. (2) This prospective, single-center, observational study included consecutive adult patients with COVID-19 pneumonia treated with a high-flow nasal cannula. Hemodynamic parameters, respiratory rate, inspiratory fraction of oxygen (FiO2), saturation of oxygen (SpO2), and the ratio of oxygen saturation to respiratory rate (ROX) were recorded prior to treatment initiation and every 2 h for 24 h. A 6-month follow-up questionnaire was also conducted. (3) Over the study period, 153 of 187 patients were eligible for HFNC. Of these patients, 80% required intubation and 37% of the intubated patients died in hospital. Male sex (OR = 4.65; 95% CI [1.28; 20.6], p = 0.03) and higher BMI (OR = 2.63; 95% CI [1.14; 6.76], p = 0.03) were associated with an increased risk for new limitations at 6-months after hospital discharge. (4) 20% of patients who received HFNC did not require intubation and were discharged alive from the hospital. Male sex and higher BMI were associated with poor long-term functional outcomes.

2.
Obstet Gynecol ; 140(2): 195-203, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35852269

RESUMO

OBJECTIVE: To evaluate whether the use of inhaled nitric oxide (iNO)200 improves respiratory function. METHODS: This retrospective cohort study used data from pregnant patients hospitalized with severe bilateral coronavirus disease 2019 (COVID-19) pneumonia at four teaching hospitals between March 2020 and December 2021. Two cohorts were identified: 1) those receiving standard of care alone (SoC cohort) and 2) those receiving iNO200 for 30 minutes twice daily in addition to standard of care alone (iNO200 cohort). Inhaled nitric oxide, as a novel therapy, was offered only at one hospital. The prespecified primary outcome was days free from any oxygen supplementation at 28 days postadmission. Secondary outcomes were hospital length of stay, rate of intubation, and intensive care unit (ICU) length of stay. The multivariable-adjusted regression analyses accounted for age, body mass index, gestational age, use of steroids, remdesivir, and the study center. RESULTS: Seventy-one pregnant patients were hospitalized for severe bilateral COVID-19 pneumonia: 51 in the SoC cohort and 20 in the iNO200 cohort. Patients receiving iNO200 had more oxygen supplementation-free days (iNO200: median [interquartile range], 24 [23-26] days vs standard of care alone: 22 [14-24] days, P=.01) compared with patients in the SoC cohort. In the multivariable-adjusted analyses, iNO200 was associated with 63.2% (95% CI 36.2-95.4%; P<.001) more days free from oxygen supplementation, 59.7% (95% CI 56.0-63.2%; P<.001) shorter ICU length of stay, and 63.6% (95% CI 55.1-70.8%; P<.001) shorter hospital length of stay. No iNO200-related adverse events were reported. CONCLUSION: In pregnant patients with severe bilateral COVID-19 pneumonia, iNO200 was associated with a reduced need for oxygen supplementation and shorter hospital stay.


Assuntos
Tratamento Farmacológico da COVID-19 , Feminino , Humanos , Óxido Nítrico , Oxigênio , Gravidez , Estudos Retrospectivos , SARS-CoV-2
4.
Crit Care Explor ; 3(6): e0471, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34151287

RESUMO

IMPORTANCE: Prone positioning improves clinical outcomes in moderate-to-severe acute respiratory distress syndrome and has been widely adopted for the treatment of patients with acute respiratory distress syndrome due to coronavirus disease 2019. Little is known about the effects of prone positioning among patients with less severe acute respiratory distress syndrome, obesity, or those treated with pulmonary vasodilators. OBJECTIVES: We characterize the change in oxygenation, respiratory system compliance, and dead-space-to-tidal-volume ratio in response to prone positioning in patients with coronavirus disease 2019 acute respiratory distress syndrome with a range of severities. A subset analysis of patients treated with inhaled nitric oxide and subsequent prone positioning explored the influence of pulmonary vasodilation on the physiology of prone positioning. DESIGN SETTING AND PARTICIPANTS: Retrospective cohort study of all consecutively admitted adult patients with acute respiratory distress syndrome due to coronavirus disease 2019 treated with mechanical ventilation and prone positioning in the ICUs of an academic hospital between March 11, 2020, and May 1, 2020. MAIN OUTCOMES AND MEASURES: Respiratory system mechanics and gas exchange during the first episode of prone positioning. RESULTS: Among 122 patients, median (interquartile range) age was 60 years (51-71 yr), median body mass index was 31.5 kg/m2 (27-35 kg/m2), and 50 patients (41%) were female. The ratio of Pao2 to Fio2 improved with prone positioning in 90% of patients. Prone positioning was associated with a significant increase in the ratio of Pao2 to Fio2 (from median 149 [123-170] to 226 [169-268], p < 0.001) but no change in dead-space-to-tidal-volume ratio or respiratory system compliance. Supine ratio of Pao2 to Fio2, respiratory system compliance, positive end-expiratory pressure, and body mass index did not correlate with absolute change in the ratio of Pao2 to Fio2 with prone positioning. However, patients with ratio of Pao2 to Fio2 less than 150 experienced a greater relative improvement in oxygenation with prone positioning than patients with ratio of Pao2 to Fio2 greater than or equal to 150 (median percent change in ratio of Pao2 to Fio2 62 [29-107] vs 30 [10-70], p = 0.002). Among 12 patients, inhaled nitric oxide prior to prone positioning was associated with a significant increase in the ratio of Pao2 to Fio2 (from median 136 [77-168] to 170 [138-213], p = 0.003) and decrease in dead-space-to-tidal-volume ratio (0.54 [0.49-0.58] to 0.46 [0.44-0.53], p = 0.001). Subsequent prone positioning in this subgroup further improved the ratio of Pao2 to Fio2 (from 145 [122-183] to 205 [150-232], p = 0.017) but did not change dead-space-to-tidal-volume ratio. CONCLUSIONS AND RELEVANCE: Prone positioning improves oxygenation across the acute respiratory distress syndrome severity spectrum, irrespective of supine respiratory system compliance, positive end-expiratory pressure, or body mass index. There was a greater relative benefit among patients with more severe disease. Prone positioning confers an additive benefit in oxygenation among patients treated with inhaled nitric oxide.

6.
Respir Care ; 66(5): 758-768, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33298622

RESUMO

BACKGROUND: Dual-patient, single-ventilator protocols (ie, protocols to ventilate 2 patients with a single conventional ventilator) may be required in times of crisis. This study demonstrates a means to titrate peak inspiratory pressure (PIP), PEEP, and [Formula: see text] for test lungs ventilated via a dual-patient, single-ventilator circuit. METHODS: This prospective observational study was conducted using a ventilator connected to 2 test lungs. Changes in PIP, PEEP, and [Formula: see text] were made to the experimental lung, while no changes were made to the control lung. Measurements were obtained simultaneously from each test lung. PIP was titrated using 3D-printed resistors added to the inspiratory circuit. PEEP was titrated using expiratory circuit tubing with an attached manual PEEP valve. [Formula: see text] was titrated by using a splitter added to the ventilator tubing. RESULTS: PIP, PEEP, and [Formula: see text] were reliably and incrementally titratable in the experimental lung, with some notable but manageable changes in pressure and [Formula: see text] documented in the control lung during these titrations. Similar results were measured in lungs with identical and different compliances. CONCLUSIONS: Pressures and [Formula: see text] can be reliably adjusted when utilizing a dual-patient, single-ventilator circuit with simple, low-cost modifications to the circuit. This innovation could potentially be lifesaving in a resource-limited or crisis setting. Understanding the interactions of these circuits is imperative for making their use safer.


Assuntos
Respiração com Pressão Positiva , Ventiladores Mecânicos , Humanos , Pulmão , Respiração , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...