Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 12(1): 6107, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34671016

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) play an important role in interstellar chemistry and are subject to high energy photons that can induce excitation, ionization, and fragmentation. Previous studies have demonstrated electronic relaxation of parent PAH monocations over 10-100 femtoseconds as a result of beyond-Born-Oppenheimer coupling between the electronic and nuclear dynamics. Here, we investigate three PAH molecules: fluorene, phenanthrene, and pyrene, using ultrafast XUV and IR laser pulses. Simultaneous measurements of the ion yields, ion momenta, and electron momenta as a function of laser pulse delay allow a detailed insight into the various molecular processes. We report relaxation times for the electronically excited PAH*, PAH+* and PAH2+* states, and show the time-dependent conversion between fragmentation pathways. Additionally, using recoil-frame covariance analysis between ion images, we demonstrate that the dissociation of the PAH2+ ions favors reaction pathways involving two-body breakup and/or loss of neutral fragments totaling an even number of carbon atoms.

2.
Phys Rev Lett ; 114(12): 123002, 2015 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-25860738

RESUMO

Electron emission as a result of the interaction of clusters with intense laser pulses is commonly understood in terms of direct and evaporative ionization processes. In contrast, we provide evidence here of an important role played by autoionization in intense field ionization of molecular oxygen clusters. Superexcited states are populated during the cluster expansion, and their autoionization is observed on a ns time scale. Decay processes on fs to ps time scales are obscured by energy exchange of the emitted electrons with the environment.

3.
Gegenbaurs Morphol Jahrb ; 134(2): 155-73, 1988.
Artigo em Alemão | MEDLINE | ID: mdl-3402716

RESUMO

In 47 dissected right and left hands of adults of both sexes, kept in a moist condition, significant practical-clinical investigations of the transitional zone between forearm and hand were undertaken. In particular it was sought to determine the characteristic sizes of the extensor retinaculum, the osteofibrous tunnels, the insertion tendons of the hand and finger extensor muscles, and their tendon sheaths. Together with the palmar carpal ligament, the 2 to 3 cm wide extensor retinaculum annularly surrounds the whole circumference of the carpus. It extends obliquely from radial-proximal to ulnar-distal and conducts the extensor tendons over the carpal articulations. According to recent studies, it is divided into a superficial and a deep fibrous layer. From the undermost surface, vertical and oblique septa run to the plane of the forearm and carpal bones. They separate the fibrous portion of the 6 tendinous compartments of the dorsum manus. In 8.5% of cases, an accessory and completely independent tunnel of the extensor pollicis brevis muscle exists in the material investigated, and in 2.2% of cases, there is an additional tunnel for the extensor carpi radialis muscle. Hence, one occasionally finds 8 separate osteofibrous gliding compartments for the extensor muscles in the dorsal hand region. The longest tunnel belongs, as a rule, to the extensor digiti minimi muscle, whilst the widest pertains to the extensor digitorum muscle. Within the tunnel and also proximal and distal to it, the extensor tendons are surrounded by synovial sheaths. Because of its wide encroachment on the dorsum of the hand, the insertion tendon of the extensor digiti minimi muscle possesses the longest tendon sheath, measuring 68.8 mm. The next longest sheath, that of the extensor pollicis longus muscle, which measures 56.2 mm, begins further proximal to the gap of the radiocarpal articulation. In 12.8% of cases, there are divided sheaths of the abductor pollicis longus and of the extensor pollicis brevis muscle. The tendon sheath of both extensor carpi radiales muscles is frequently divided into 2 compartments which, in 2/3 of cases, communicate. The compartment of the extensor carpi radialis brevis muscle, in 91.5% of cases, shares a window-like opening with the roof of the synovial vagina of the extensor pollicis longus muscle. The tendon sheath of the long extensor muscles of the fingers originates 5 mm proximal to the forearm border of the extensor retinaculum and has a communal recess. The IVth tendon sheath opens distally and splays out in a glove-like manner to some distal recesses.(ABSTRACT TRUNCATED AT 400 WORDS)


Assuntos
Mãos/anatomia & histologia , Músculos/anatomia & histologia , Tendões/anatomia & histologia , Adulto , Ossos do Carpo/anatomia & histologia , Feminino , Dedos/anatomia & histologia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...