Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 107(7): 1007-1011, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35177402

RESUMO

PURPOSE: To develop a prediction model for type 1 retinopathy of prematurity (ROP) from an Asian population. METHODS: This retrospective cohort study included 1043 premature infants who had ROP screening in a tertiary hospital in Hong Kong from year 2006 to 2018. The ROP prediction model was developed by multivariate logistic regression analyses on type 1 ROP. The cut-off value and the corresponding sensitivity and specificity were determined by receiver operating characteristic curve analysis. A validation group of 353 infants collected from another tertiary hospital in another region of Hong Kong from year 2014 to 2017 was used for external validation. RESULTS: There were 1043 infants in the study group. The median gestational age (GA) was 30 weeks and 1 day and median birth weight (BW) was 1286 g. The prediction model required only GA and BW as parameters (prematurity-birth weight ROP (PW-ROP)). The area under curve value was 0.902. The sensitivity and specificity were 87.4% and 79.3%, respectively. Type 1 ROP developed in 0.9%, 17.4% and 50% of infants with PW-ROP scores<0, between 0 and <300, and ≥300 respectively (p<0.001). On external validation, our prediction model correctly predicted 95.8% of type 1 ROP (sensitivity=95.8%, specificity=74.8%) in the validation group. CONCLUSION: The PW-ROP model is a simple model which could predict type 1 ROP with high sensitivity and specificity. Incorporating this model to ROP examination would help identify infants at risk for ROP treatment.


Assuntos
Retinopatia da Prematuridade , Recém-Nascido , Lactente , Humanos , Peso ao Nascer , Idade Gestacional , Estudos Retrospectivos , Retinopatia da Prematuridade/epidemiologia , Fatores de Risco , Triagem Neonatal
2.
Case Rep Ophthalmol ; 7(3): 270-276, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28101045

RESUMO

This case report illustrates the use of ExPRESS mini-shunt in a pediatric glaucoma patient. We describe the management of steroid-induced glaucoma with ExPRESS mini-shunt in a 9-year-old boy with allergic keratoconjunctivitis. The intraocular pressure of both of his eyes was uncontrolled with medical and laser treatment. Both eyes were treated with ExPRESS mini-shunt and mitomycin-C. Transient overfiltration with postoperative hypotony occurred in both eyes and resolved after 2 weeks. One year postoperatively, intraocular pressure was maintained below 21 mm Hg without medication in 1 eye. Bleb needling with mitomycin-C was done to maintain filtration. The fellow eye received cataract extraction but developed bleb failure a few months afterwards. The intraocular pressure was controlled medically. To conclude, ExPRESS mini-shunt is a new surgical option in selected patients. Bleb failure developed after cataract extraction. Postoperative inflammation should be minimized. Patient selection, such as those with stable ocular condition, is important to increase surgical success.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...