Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Heart Lung Circ ; 25(6): 592-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26809463

RESUMO

BACKGROUND: We investigated the ability of cardiac biomarkers and total pulmonary artery (PA) clot score to predict right ventricular dysfunction (RVD) on admission and at seven-month follow-up in subjects with acute pulmonary embolism (APE). METHODS: Sixty-three normotensive patients with APE were divided into two groups: patients with (n= 32, age 58±19 years) and without (n=31, age 55±16 years) echocardiographic RVD. Transthoracic echocardiography (TTE), N-terminal pro-brain natriuretic peptide (NT-proBNP), and high-sensitivity troponin T (hsTnT) were assessed upon arrival and repeated at seven months. Total PA clot score was determined on admission. RESULTS: The age- and sex dependent NT-proBNP on admission, on day 5, and at seven months exhibited the best sensitivity (admission 94%, day 5 100%, seven months 100%) and negative predictive value (NPV) (89%, 100%, 100%) for detecting RVD. Six patients (10%) had persistent RVD at seven months. Total PA clot score showed only low to moderate sensitivity (77%) and PPV (7%) for detection of RVD at seven months. CONCLUSIONS: Normal age- and sex dependent NT-proBNP on admission or measured five days later seems to be useful in exclusion of RVD at follow up. Total PA clot score shows only to be of modest benefit for predicting persistent RVD.


Assuntos
Ecocardiografia , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar , Trombose , Troponina/sangue , Disfunção Ventricular Direita , Adulto , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico por imagem , Trombose/sangue , Trombose/diagnóstico por imagem , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/diagnóstico por imagem
2.
Scand J Trauma Resusc Emerg Med ; 20: 33, 2012 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-22559861

RESUMO

BACKGROUND: Right ventricular dysfunction (RVD) in acute pulmonary embolism (APE) can be assessed with helical computerized tomography (CT) and transthoracic echocardiography (TTE). Signs of RVD and elevated natriuretic peptides like NT-proBNP and cardiac troponin (TnT) are associated with increased risk of mortality. However, the prognostic role of both initial diagnostic strategy and the use of NT-proBNP and TnT for screening for long-term probability of RVD remains unknown. The aim of the study was to determine the role of helical CT and NT-proBNP in detection of RVD in the acute phase. In addition, the value of NT-proBNP for ruling out RVD at long-term follow-up was assessed. METHODS: Sixty-three non-high risk APE patients were studied. RVD was assessed at admission in the emergency department by CT and TTE, and both NT-proBNP and TnT samples were taken. These, excepting CT, were repeated seven months later. RESULTS: At admission RVD was detected by CT in 37 (59 %) patients. RVD in CT correlated strongly with RVD in TTE (p < 0.0001). NT-proBNP was elevated (≥ 350 ng/l) in 32 (86 %) patients with RVD but in only seven (27 %) patients without RVD (p < 0.0001). All the patients survived until the 7-month follow-up. TTE showed persistent RVD in 6 of 63 (10 %) patients who all had RVD in CT at admission. All of them had elevated NT-proBNP levels in the follow-up compared with 5 (9 %) of patients without RVD (p < 0.0001). CONCLUSIONS: TTE does not confer further benefit when helical CT is used for screening for RVD in non-high risk APE. All the patients who were found to have RVD in TTE at seven months follow-up had had RVD in the acute phase CT as well. Thus, patients without RVD in diagnostic CT do not seem to require further routine follow-up to screen for RVD later. On the other hand, persistent RVD and thus need for TTE control can be ruled out by assessment of NT-proBNP at follow-up. A follow-up protocol based on these findings is suggested.


Assuntos
Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Espiral , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/diagnóstico por imagem , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Troponina T/sangue
3.
Thromb Res ; 118(5): 573-85, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16040082

RESUMO

INTRODUCTION: Normal concentrations of D-Dimer can be used to exclude venous thromboembolism (VTE). However, methods for sensitive and quantitative D-Dimer measurements at the point-of-care (POC) are still limited. MATERIALS AND METHODS: We developed a 10-min, non-competitive immunofluorometric assay for D-Dimer in citrated whole blood and plasma using pre-dispensed reagents dried in single assay wells. The simple, automated assay procedure comprises a 1:50 sample dilution, one-step incubation, washing, and time-resolved fluorometric measurement directly from the wet well surface. RESULTS: The limits of detection (background + 3SD) and quantification (CV <15%) were 0.05 and 0.2 mg/L D-Dimer, respectively, and the assay was linear up to 400 mg/L. Correlations to Roche TinaQuant (r=0.726, n=200) and Biopool Auto.Dimer (r=0.190, n=149) were carried out using citrated plasma. Diagnostic sensitivity, specificity, and negative (NPV) and positive (PPV) predictive values were 98.7%, 64.4%, 99.1% and 55.1%, and 92.2%, 81.0%, 95.9% and 68.3%, respectively, using cut-off values of 0.6 and 1.0 mg/L, respectively, in outpatients with deep vein thrombosis (DVT) and/or pulmonary embolism (PE) (n=77) compared with outpatients with various other diseases (n=174). The within- and between-run CVs near the cut-off values were < or =10% in both whole blood and plasma. The 95th percentile upper range in apparently healthy individuals was 0.68 mg/L of whole blood (n=101). CONCLUSIONS: The high sensitivity and NPV suggest that the rapid immunofluorometric assay could be valuable for rapid exclusion of VTE in outpatients. With appropriate cut-offs, the assay could potentially be used as a stand-alone test or combined with clinical probability assessment, but further studies are required.


Assuntos
Análise Química do Sangue/métodos , Testes de Coagulação Sanguínea/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Fluorimunoensaio/métodos , Anticorpos Monoclonais , Produtos de Degradação da Fibrina e do Fibrinogênio/imunologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...